Summary of Contents for Reach Technology SLCD+

  • Page 1 SLCD+ Controller Manual V1.1 August 14, 2009 For SLCD+ Hardware Revision A, RoHS Compliant © Copyright Reach Technology Inc. 2003-2009 All Rights Reserved Note: the software included with this product is subject to a license agreement as described in this Manual.
  • Page 2: Table Of Contents

    Table of Contents HARDWARE LIMITED WARRANTY AND SOFTWARE LICENSE AGREEMENT ........................ 5 0.1..................5 ARDWARE IMITED ARRANTY 0.2..................5 ETURNS AND EPAIR OLICY 0.3..................6 OFTWARE ICENSE GREEMENT INTRODUCTION ......................8 1.1......................... 8 VERVIEW 1.2.......................... 8 EATURES 1.3.
  • Page 3 APPENDIX A - PANELS COMPATIBLE WITH THE SLCD+ CONTROLLER ....24 SX14Q001[-ZZA] SX14Q004[-ZZA] ............. 24 ITACHI TX14D11VM1CAA-1 (CBA ) ............24 ITACHI O TOUCH 5.7" CSTN K KCG057QV1DC-G50 ............ 24 OLOR YOCERA 5.7" TFT K TCG057QV1AB-G00 TCG057QV1AA-G00 ....24 OLOR YOCERA 5.5"...
  • Page 4 Figures 1: R )................9 IGURE OARD HYSICAL IMENSIONS INCHES 2: C (J11 ) ..............12 IGURE ONNECTORS AND UMPERS NOT INSTALLED SLCD+ Controller Manual V1.1 8/14/2009 Page 4...
  • Page 5: Hardware Limited Warranty And Software License Agreement

    RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number, and return address. Authorized returns must be shipped freight prepaid to Reach Technology Inc. 4575 Cushing Parkway, Fremont, California 94538 with the RMA number clearly marked on the outside of all cartons.
  • Page 6: Software License Agreement

    This License Agreement (“Agreement”) is a legal contract between you (either an individual or a single business entity) and Reach Technology Inc. (“Reach”) for software referenced in this guide, which includes computer software and, as applicable, associated media, printed materials, and “online”...
  • Page 7 This warranty does not apply if the software (a) has been altered, except by Reach, (b) has not been installed, operated, repaired, or maintained in accordance with instructions supplied by Reach, (c) has been subjected to abnormal physical or electrical stress, misuse, negligence, or accident, or (d) is used in ultrahazardous activities.
  • Page 8: Introduction

    Introduction Overview 1.1. The SLCD+ controller provides complete Graphical User Interface for embedded systems using QVGA or smaller LCD panels. Using the SLCD is simply the quickest way to generate a user interface without a lot of graphical programming. It has a small size to fit in space-constrained applications.
  • Page 9: Dimensions - Rev Gboard

    Dimensions - Rev G board 1.3. Figure 1: SLCD+ Rev A Board Physical Dimensions (inches) SLCD+ Controller Manual V1.1 8/14/2009 Page 9...
  • Page 10: Electrical Characteristics

    The SLCD+ board takes in two voltages. One is simply passed though to the backlight inverter, and is typically either 5V or 12V. The SLCD+ itself requires 5V. For other hardware options, contact Reach Technology Inc. The SLCD+ is designed for panels with VCC of 3.3V and built-in DC-DC converters and therefore do not need high positive or negative voltages.
  • Page 11: Configuration Guide

    Configuration Guide Power 2.1. Note: The standard configuration is for 5V power input and 3.3V panel power. For other configurations, please contact Reach. Serial 2.2. The SLCD+ has four serial ports. Any can be used to send commands to the board. The ports and their characteristics are as follows: Port Description...
  • Page 12: Connectors And Jumpers

    Connectors and Jumpers Figure 2: Connectors and Jumpers J6 - Power and COM0 (RS232 communications mode) 3.1. J6 8 Pin Molex 53261-0871 for Power and Communications RS232 Mode – R24 installed on board do not connect do not connect RS232 input * RS232 output Backlight voltage (typ.
  • Page 13: J4 - Com2 Rs232 Port

    Typical connection from a PC is as follows: Backlight Voltage 5V in SLCD WITH PC DATA OUT R24 INSTALLED PC DATA IN AMP 747844-4 Molex 53261-0890 PC serial compatible pinout DB9 Female J4 – COM2 RS232 port 3.2. J4 3 Pin Molex 53261-0371 or equivalent RS232 Mode –...
  • Page 14: J12 - 4 Wire Touch

    J12 - 4 Wire Touch 3.4. J12 4 Pin Molex 52271-0469 or equivalent 1mm pitch bottom contact Zero-Insertion-Force Connector Signal X1 (left / right / up / down)* Y1 (up / down / left / right )* X2 (right / left / down / up )* Y2 (down / up / right / left )* * The sense of X and Y and up / down / right / left is determined by the touch calibration procedure –...
  • Page 15: J7 - 20 Pin 0.5Mm Flat Flex Lcd Connector

    J7 - 20 pin 0.5mm Flat Flex LCD Connector 3.7. J7 20 Pin Omron XF2M-2015-1A or equivalent 0.5mm pitch Zero-Insertion-Force Connector Signal Signal LCD Frame Pulse LCD Data 4 LCD Line Pulse LCD Data 3 LCD Clock LCD Data 2 LCD Display On (DISPOFF-) LCD Data 1 LCD VCC...
  • Page 16: J10 - Backlight / Inverter Control

    J10 - Backlight / Inverter Control 3.10. J10 4 Pin Molex 53261-0471 Signal Backlight power (connected to J6 pin 5) Ground Backlight on/off control; can also be used as PWM for dimming Backlight brightness control This connector is used to power and control the panel backlight. The sense of the on/off control (active high or low) is set in the firmware.
  • Page 17: System Overview

    System Overview General SLCD+ Controller 4.1. The SCLD acts as a "smart terminal" and is generally connected to a host processor that implements the desired Graphical User Interface (GUI) by issuing commands to the SLCD+ and processing button press responses from the SLCD+. In this manual, the term "host"...
  • Page 18: 4.2.3. Developing The Application Gui With An Embedded Controller As Host

    As shipped, the serial port is set to 115,200 baud, 8 bit, 1 start, 1 stop, no parity. There are two DB9 connectors on the "PowerCom 4" board. Connect the PC using a straight through cable to the DB9 marked "MAIN" (P1). A USB-to-serial adapter cable can also be used and plugged directly into this connector.
  • Page 19: Powercom4 Board

    PowerCom4 Board 4.3. PowerCom4 Board SLCD+ Controller Manual V1.1 8/14/2009 Page 19...
  • Page 20: Powercom4 Schematic

    PowerCom4 Schematic 4.4. SLCD+ Controller Manual V1.1 8/14/2009 Page 20...
  • Page 21: Kit / Powercom4 Operational Notes

    Kit / PowerCom4 Operational Notes 4.5. 1. The unit default baud rate is 115200. The unit does not echo characters (for communications efficiency), so you must select "echo characters locally" or "half duplex" in your PC communications program. Also, all return strings are terminated by a <return>...
  • Page 22: Communications Interface

    Communications Interface 4.6. General Default communication is at a baud rate of 115200 with no parity, software (XON/XOFF) flow control, 8 bits of data, and 1 stop bit. The baud rate can be set to a different initial value on power-on by using the POWER-ON MACRO feature. Characters are not echoed and all responses end only with a <return>...
  • Page 23: Software Command Reference

    Software Command Reference The software commands and utilities are described in a separate document, the SLCDx Software Reference Manual. SLCD+ Controller Manual V1.1 8/14/2009 Page 23...
  • Page 24: Appendix A - Panels Compatible With The Slcd+ Controller

    Appendix A - Panels compatible with the SLCD+ controller The SLCD+ controller has been tested with the following panels: Hitachi SX14Q001[-ZZA] and SX14Q004[-ZZA] Color STN 5.7" (-ZZA for integrated touch screen) 3.3V operation Plugs directly into SLCD+ J8 Hitachi TX14D11VM1CAA-1 (CBA w/o touch) Color TFT 5.7", standard mounting, with or without touch 3.3V operation Reach supplies a custom Flat Flex cable for SLCD+ J7...
  • Page 25: Color 5.7" Tft Sharp Lq057Q3Dc02

    Color 5.7" TFT Sharp LQ057Q3DC02 Color TFT 5.7" high brightness 3.3V operation Can use 3M touch screen Plugs directly into SLCD+ J9 using 33 pin flat flex cable available from Reach or www.axoncable.com Color TFT Sharp small LQ038Q5DR01 - 3.8" high brite LQ050Q5DR01 - 5.0"...
  • Page 26: Appendix B - Parts And Suppliers For Slcd+ Controller Connections

    Appendix B - Parts and suppliers for SLCD+ controller connections Connectors and cables for J6, J10 The board connector is Molex type 53261-0890 (J6) and 53261-0490 (J10). The mating connector is made of two parts: a receptacle housing and crimp pins. A special tool is needed to make the crimps.
  • Page 27: Appendix C - Ordering Information

    Appendix C - Ordering information Contact Reach directly for ordering information. Reach Technology Inc 4575 Cushing Parkway Fremont, California 94538 (510) 770-1417 SLCD+ Controller Manual V1.1 8/14/2009 Page 27...
  • Page 28: Appendix D - Troubleshooting

    Appendix D - Troubleshooting Touch unreliable or non-operative If the touch screen is unreliable or non-operative, do the following: Make sure the metal shell of the display is connected to one of the SLCD+ mounting holes. This is the same as saying that the display case should be grounded to SLCD+ ground.
  • Page 29: Appendix E - Using Com0 / J6 For 3.3V Cmos Interface

    Appendix E – Using COM0 / J6 for 3.3V CMOS Interface The SLCD+ serial port COM0 is typically used for communication using RS232 levels. However, by removing resistor R24, it can use 3.3V CMOS logic levels. COM0 Logic Level Mode: 1.
  • Page 30 Backlight Voltage 5V in 3.3V CMOS SLCD WITH LEVELS * R24 REMOVED Molex 53261-0890 * 5V CMOS LEVELS is panel power is 5V SLCD+ Controller Manual V1.1 8/14/2009 Page 30...