WATANABE WPMZ-3 Series Quick Instruction Manual page 5

Graphical digital panel meter
Hide thumbs Also See for WPMZ-3 Series:

Advertisement

MODEL WPMZ-3-□□□-□□-□□□
1st Layer
2nd Layer
2InputCalc
ExternalCtrl
1. Input
Hold A/B
CompareAL1
CompareAL2
CompareAL3
CompareAL4
2.Output
AnalogOutput
BCD Output
ModbusCom
RS-232C Com
DispSelect
LevelDisp
3.Display
TrendDisp
4.System
General
3rd Layer
(setting items)
Initial values
InsDispStep
None
Lower:-99999
DispLimit
Upper:+99999
ExtCtrl 1~5 Func
None
PatternSelect
Pattern in use
DispHoldMode
Normal
HoldOffDelay
0.00
HoldMode
NormalHold
DevBaseValue
0
AveHoldCount
None
PatternSelect
Pattern in use
OutputDispValue
None
ActCondition
Always
CompareMode
LevelJudge
Excess
OnConditions
InTheZone
10000
0
0
Threshold
10000
0
10000
1.00
OnDelay
None
OffDelay
None
OutputMode
Normal
OutputLogic
Negative
OnBgColors
Black
PatternSelect
Pattern in use
OutputRange
0-10V
OutputDispValue
None
0
OutputScale
10000
PatternSelect
Pattern in use
OutputDispValue
None
DataSignalLogic
Negative
SyncSignalLogic
Negative
SlaveAddress
1
Baudrate
19200bps
Parity
Even
Protocol
Modbus-RTU
Baudrate
19200bps
Parity
Even
DataLength
7bit
Stopbit
1bit
Delimiter
CR LF
1ch product
Ach, Ach +
MeasureSelect
Comp
Level, Trend
2ch product
LevelSelect
Ach + Bch,
TrendSelect
Level, Trend
PatternSelect
Pattern in use
Ach Scale
0
Bch Scale
10000
CalcScale
AL Select
AL1-AL4:ON
PatternSelect
Pattern in use
Ach Scale
0
Bch Scale
10000
CalcScale
AL Select
AL1-AL4:ON
TimeAxis
1s/div
Brightness
5 Bright
PowerOnDelay
None
PowerSavingTime
None
4th Layer (setting values)
Initial values
None/5steps/10steps
±99999
±99999
None/CompareReset/HoldResetA,B,A&B
/DispHoldA,B,A&B/Peak_HoldA,B,A&B
/BottomHoldA,B,A&B/AmpHoldA,B,A&B
/DevHoldA,B,A&B/AveHoldA,B,A&B
/DigitalZeroA,B,A&B/PatternChange1,2,3
/DispChange/TrendLog/WaveCompA,B/Mu
ltiHoldA,B
Pattern 1/2/3/4/5/6/7/8
Normal/OneShot
0.00~99.99[sec]
NormalHold/AreaHold
±99999
None/2/4/8/16/32/64times
Pattern 1/2/3/4/5/6/7/8
None/Ach/Bch/Calc
Always/ExceptNearZero/OnStable
/ OnStableExceptNearZero/OnHold
LevelJudge/ZoneJudge/DiffJudge
Excess/LessThan
InTheZone/OutsideTheZone
Threshold:±99999
Hysterisis:0~99999
ZoneLowerLimit:±99999
ZoneUpperLimit:±99999
Hysterisis:0~99999
ChangeAmount:±99999
DetectionInterval:0.00~99.99[sec]
None/20ms/50ms/100ms/200ms/500ms
1s/5s/10s/20s
Normal/Latch/OneShot5ms/10ms/20ms
/50ms/0.1s/0.2s/0.5s/1s/2s
Positive/Negative
Black/Red/Yellow/Green
Pattern 1/2/3/4/5/6/7/8
0-10V/±10V/1-5V/0-20mA/4-20mA
None/Ach/Bch/Calc
0%:±99999
100%:±99999
Pattern 1/2/3/4/5/6/7/8
None/Ach/Bch/Calc
Positive/Negative
Positive/Negative
1~31
9600bps/19200bps/38400bps
None/Even/Odd
ModbusRTU/OriginalCommand/OriginalO
utput
9600bps/19200bps/38400bps
None/Even/Odd
7bit/8bit
1bit/2bit
CR / CR LF
Ach/Bch/Calc/Ach+Comp/Bch+Comp
/Calc+Comp/Ach+Bch/Calc+A+B
Ach/Bch/Calc/Ach+Bch
Pattern 1/2/3/4/5/6/7/8
LowerLimit:±99999
UpperLimit:±99999
AL1/AL2/AL3/AL4
Pattern 1/2/3/4/5/6/7/8
LowerLimit:±99999
UpperLimit:±99999
AL1/AL2/AL3/AL4
1s/div,2s/div,5s/div,10s/div,
30s/div,60s/div120s/div
5Bright/4/3/2/1Dark/0 Off
None/2sec/5sec/10sec/20sec/30sec/60sec
None/1/2/5/10/30/60min
5/12
Remarks
Take over setting of [DecPoint].
Select a function which is attached to each
external control terminals.
Select pattern No. to set.
Select a mode of DispHold.
Take over setting of [DecPoint].
Select pattern No. to set.
Select a condition of comparison.
Only LevelJudge.
Only ZoneJudge.
Only LevelJudge.
Only ZoneJudge.
Only DiffJudge
Compare ON/OFF after ActCondition is
kept certain time set here.
Select an output mode.
Select an output logic.
Priority: AL1 > AL2 > AL3 > AL4
Select pattern No. to set.
Select a type of output range.
Select a ch referenced for analog output.
Scaling of analog output.
Set 0% and 100% value.
Select pattern No. to set.
Select a ch referenced for BCD output.
Select an output mode.
Select an output mode.
Set ID of the product.
Select a baudrate.
Select a type of parity bit.
Select a protocol.
Select a baudrate.
Select a type of parity bit.
Enable when Protocol is
OriginalCommand or OriginalOutput.
Enable when Protocol is
OriginalCommand or OriginalOutput.
Enable when Protocol is
OriginalCommand or OriginalOutput.
*Bch and Calc is enable in 2ch product.
*Bch and Calc is enable in 2ch product.
Select pattern No. to set.
Set scale of level screen.
Select pattern No. to set.
Set scale of trend screen.
Set time scale of division time.
Off means that whole of secreen is turned
off.
Set time that until measure after power
on.
Display is dark while power saving.