OfiTE 120-700 Instruction Manual

Hthp corrosion tester

Advertisement

Quick Links

HTHP Corrosion Tester
Instruction Manual
OFI Testing Equipment, Inc.
11302 Steeplecrest Dr. · Houston, Texas · 77065 · U.S.A.
Tele: 832.320.7300 · Fax: 713.880.9886 · www.ofite.com
#120-700
Updated 5/22/2020
Ver. 6
Copyright OFITE 2015
©

Advertisement

Table of Contents
loading

Summary of Contents for OfiTE 120-700

  • Page 1 HTHP Corrosion Tester #120-700 Instruction Manual Updated 5/22/2020 Ver. 6 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. · Houston, Texas · 77065 · U.S.A. Tele: 832.320.7300 · Fax: 713.880.9886 · www.ofite.com Copyright OFITE 2015 ©...
  • Page 2: Table Of Contents

    Beginning a Test .................4 Ending a Test ................6 Appendix ..................7 Temperature Controller ...............7 Timer ..................10 Maintenance ................11 Rupture Disk ................11 Warranty and Return Policy ............12 OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com...
  • Page 3: Components

    Viton o-rings will be required after every test. Maximum Pressure: 5,000 PSI (34.5 MPa) Sample Capacity: 4 Jars Mineral Oil Used Per Test: Approximately 1 to 1.5 quarts OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com...
  • Page 4: Setup

    7. Ensure that all electrical switches are off and plug the unit into a grounded electrical outlet. The electrical socket is located on the back of the unit. A 220-VAC, 20-amp power source is recommended. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com...
  • Page 5: Testing

    11. Place the bottles into the sample rack and place the rack into the test cell using the lift bail. Remove the lift bail and record the time. Sample Rack with Bottles OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com...
  • Page 6 19. Start the test exactly five minutes after the mineral oil reaches the test temperature. Record the test time, temperature, and pressure at the start of the test. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com...
  • Page 7: Ending A Test

    16. Report the inhibitor performance as weight loss (mg) per time exposed. 17. Close all valves and turn all switches off. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com...
  • Page 8: Appendix

    “Scroll” button to decide which setting to change. Use the arrow buttons to change the values for that setting. Temperature Controller RUN/HOLD Page Scroll OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com...
  • Page 9 To stop the test, push and hold the “Run/Hold” button until the light for Run and Hold both turn off. Be sure and turn the “HEAT” switch off as well. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com...
  • Page 10 8. Use the up and down arrow keys to adjust the alarm setpoint to the required value. 9. Press the “PAGE” key nine times to return to the default display. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com...
  • Page 11: Timer

    While running, the timer counts in minutes. It may not immediately appear to be working. But after one minute, the readout will advance to 2. Timer Front Panel Layout OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com...
  • Page 12: Maintenance

    The rupture disc is located in the second block from the tee. Rupture Disk #122-052 OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com...
  • Page 13: Warranty And Return Policy

    In the event that OFITE is requested to provide customized research and development for the buyer, OFITE shall use its best efforts but makes no guarantees to the buyer that any products will be provided. OFITE makes no other warranties or guarantees to the buyer, either express or implied,...