Section 4 Remote Control Pairing; Pairing Procedure; Unpairing Procedure - Will Burt Nightscan Spot Operator's Manual

Table of Contents

Advertisement

N
S
S
O
IGHT
CAN
POT
PERATOR
Section 4
The default state for the Night Scan Spot is to be unpaired to any Remote Control. To avoid
interference from other Remote Control devices that are within range, it is highly recommended
that the light be paired to a Remote Control.
Any Night Scan Spot Remote Control can be paired to Night Scan Spot, however no more than
two Remote Controls can be paired to the same Night Scan Spot. If a third Remote Control is
paired to the same Night Scan Spot, the first Remote Control will be automatically unpaired.
Note: The pairing or unpairing process will timeout after 1 minute of inactivity.

4.1 Pairing Procedure

To pair a Remote Control:
1. Turn the Night Scan Spot on with the ON/OFF button.
2. Within 1 minute, press and hold the ON/OFF button on the Remote Control for 6
seconds. Once the Remote Control is paired to the light, the light will flash 3 long flashes
and then turn off. Pairing is complete.
3. To pair a second Remote Control, repeat steps 1 and 2.

4.2 Unpairing Procedure

The Remote Control(s) can unpaired unpaired whether the light is on or off. Unpairing will unpair
all Remote Controls, returning the Night Scan Spot to its default state and allowing the Night
Scan Spot to be controlled by any unpaired Remote Control within operating distance.
To unpair the Remote Control(s):
1. Turn the Remote Control on or off.
2. Within 1 minute, press and hold the ON/OFF button on the Remote Control for 6
seconds. Once unpaired, the light will flash 3 short flashes and turn off. The light is now
unpaired and will reset to the default mode.
6
'
M
S
ANUAL
Remote Control Pairing
TP-5590101-B
October 2019

Advertisement

Table of Contents
loading

This manual is also suitable for:

5584901

Table of Contents