Connecting to Power

Connect the supplied AC power cord to the receptacle on the back of the switch,
and then plug the cord into a standard AC outlet with a voltage range from 100
to 250 VAC.
Figure 3. Rear panel view of Pro-Switch/8F
Turn the switch on by flipping the ON/OFF switch on the rear of the unit to the I
(ON) position. The O position is OFF.
8

General Installation

This chapter presents step-by-step installation instructions for this eight-
port Ethernet Switch.
Selecting a Site for the Switch
As with any electronic device, you should place the Switch where it will not
be subjected to extreme temperatures, humidity, or electromagnetic
interference. Specifically, the site you select should meet the following
requirements:
• The room temperature should be between 32 and 104 degrees
Fahrenheit (0˚- 40˚ Celsius).
• The relative humidity should be less than 90%, non-condensing.
• Surrounding electrical devices should not exceed the electromagnetic
field (RFC) standards for IEC 801-3, Level 2 (3V/M) field strength.
• Make sure that the switch receives adequate ventilation. Do not block
the ventilation holes on the side of the switch or the fan exhaust port
on the rear of the switch.
• The power outlet should be within 1.8 meter (6 feet) of the switch.