ADC OmniReach NCX-1000s Specification Sheet

Distribution intercept cross-connect for coolped cabinets

Advertisement

Quick Links

OmniReach
Distribution Intercept Cross-Connect for CoolPed
The NCX-1000s service delivery cross connect is designed for customers who use the Emerson
CoolPed
cabinet for hardend DSLAM applications. The NCX-1000s utilizes ADC's patented
Distribution Intercept (DI) broadband service delivery cross-connect and mounts inside the
CoolPed cabinet offering the same streamlined broadband service delivery as found in ADC's
family of NCX-1000 cabinets. The NCX-1000s combined with the CoolPed allows you to
strategically place the cabinet anywhere in the network to achieve the required loop lengths
for optimum bandwidth. Simple straight splicing to the outside plant cable is all that is needed
to begin turning up customers.
ADC's OmniReach
FTTX Solutions are the industry's first infrastructure solutions designed
®
from the ground up to meet the unique requirements of FTTX networks. Designed for operational
efficiency and scalability, OmniReach solutions simplify FTTX network installation, maintenance
and management from the central office/headend to the outside plant.
Features
NCX-1000s and mounting brackets for
CoolPed cabinet installation, OSP cable
stubs 12' for easy splicing into DSLAMs
and network
Works with existing feeder/distribution
cross box or can replace it
Sized from 48 DSLAM ports and 100 OSP
intercept pairs to 144 DSLAM ports and
600 OSP intercept pairs
w w w . a d c . c o m
NCX-1000s
®
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
Able to groom all existing xDSL shelves into
a single format and provide cross-connect
capability in addition to pair-bonding
Provides a consistent interface
for technicians
1 - 8 0 0 - 3 6 6 - 3 8 9 1
Cabinets

Advertisement

loading

Summary of Contents for ADC OmniReach NCX-1000s

  • Page 1 ™ Distribution Intercept (DI) broadband service delivery cross-connect and mounts inside the CoolPed cabinet offering the same streamlined broadband service delivery as found in ADC's family of NCX-1000 cabinets. The NCX-1000s combined with the CoolPed allows you to strategically place the cabinet anywhere in the network to achieve the required loop lengths for optimum bandwidth.
  • Page 2 OmniReach Distribution Intercept Cross-Connect for CoolPed Distribution Intercept The heart of the NCX-1000s is ADC’s patented Distribution Intercept (DI) cross-connect using LSA-PLUS Series 2 IDC connectivity. • B rown Series 2 switching blocks route POTS into the DSLAM and present the combined DSLAM output of POTS/xDSL signals. • White Series 2 disconnect blocks provide OSP input and output terminations. Once the DI is spliced onto either feeder or distribution outside plant cable, broadband service activation occurs with a simple 2 pair jumper between brown and white blocks and insertion of a green activation plug.
  • Page 3: Specifications

    OmniReach Distribution Intercept Cross-Connect for CoolPed Benefits • Can be deployed in feeder or distribution outside plant cable, the most flexible solution available • Fastest to deploy, only straight splicing activities to OSP required DLC Remote Cabinet DLC Remote Cabinet Specifications GENERAL SPECIFICATIONS Mounting:...
  • Page 4 ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S.