PowerStrip Snap DS
®

Electrical Connections

Connect modules using twist-on
1
wire connectors or in-line (IDC)
connectors. Join white wires
together and red striped wires
together.
Cap all exposed wires with
2
appropriate end caps or apply
electric grade (non-corrosive) silicone
for additional weather protection.
NOTES:
• Exceeding maximum load will cause the power supply to shut down. If overload occurs, remove excess load, recycle
the input power to restart the power supply.
• All electrical connections should be suitably protected from mechanical damage and the environment. Seal
all connections in locations that may be exposed to water with electrical grade RTV silicone. See page 3 for
recommended silicones.
Must be used with Tetra ® 24 Volt Power Supplies.
Additional supply wire may be necessary to bridge electrical connections.
Wire nuts should be facing up so as not to collect water.
2
Last
module
1
Connect output side of
3
power supply to first
module. Connect the
red stripe wire (+) of the
LED system to the red wire
(+) of the power supply.
Connect the white wire (-) of
the LED system to the black
or blue wire (-) of the power
supply. Connect AC line to
input side of power supply.
7
Installation Guide
1
Power
First
supply
module
3
AC line