PiPeLine TaBLe fOr BUrners mODeL BT 250 Dsg-4T
graViTY feeD sYsTem
PUMP AXIS
siPHOn feeD sYsTem WiTH feeD frOm THe TOP Of THe TanK
PUMP AXIS
inTaKe sUPPLY sYsTem
PUMP AXIS
1
2
3
4
5
6
7
8
9
1
3
4
6
7
8
9
10
1
3
4
6
7
10 Foot valve
NOTE:
Comply with the regulations in force for any components missing in the pipelines.
H
Difference in level between min. level in tank and pump axis.
L
Total length of each pipe including the vertical section Deduct 0.25 m for each elbow or gate.
10 / 24
0006160029_201305
Tank
Feeding pipe
Wire-net filter
Pump
Degasifier
Suction pipe
Burner return pipe
Automatic shut-off device with
burner off
One-way valve
Tank
Wire-net filter
Pump
Suction pipe
Return pipe
Automatic shut-off device with
burner off
One-way valve
Foot valve
Tank
Wire-net filter
metres
Pump
Suction pipe
Return pipe
H
L Total in meters
metres
Ø i=16
Ø i=18mm
mm
1
30
40
1.5
35
45
2
35
45
2.5
40
50
3
40
50
H
L Total in meters
metres
Ø i=16
Ø i=18mm
mm
1
30
40
1.5
35
45
2
35
45
2.5
40
50
3
40
50
Dimension P = 3.5 m. (max.)
L Total in meters
H
Ø = 16mm
Ø =18 mm
0.5
21
34
1
18
29
1.5
15
24
2
11.5
19
2.5
8.5
14
3
5.5
9
3.5
-
3.5