Specific Information
Regarding R290
Refrigerant Gas
The appliance must be installed, used
and stored in an area that is greater
than 13m
.
2
This appliance contains 265g of R290
refrigerant gas.
R290 is a refrigerant gas that
complies with the European directive
on the environment.
Do not puncture any part of
refrigerant circuit.
Be aware R290 refrigerant is
odourless and does not have the
odour normally associated with
natural gas and propane tanks.
The appliance must be placed in an
area without any continuous sources
of ignition such as open flames, gas,
or electrical appliances in operation.
Do not puncture and do not burn.
If the appliance is installed, operated
or stored in a non-ventilated area, the
room must be designed to prevent
the accumulation of refrigerant leaks
resulting in a risk of fire or explosion
due to ignition of the refrigerant
caused by electric heaters, stoves, or
other sources of ignition.
The appliance must be stored in
such a way as to prevent mechanical
failure.
Individuals who operate or work on
the refrigerant circuit must have the
appropriate certification issued by an
accredited organisation that ensures
competence in handling refrigerants
according to a specific evaluation
recognised by associations in the
industry.
04 | English
Maintenance and repairs that require
the assistance of other qualified
personnel must be performed under
the supervision of an individual
specified in the use of flammable
refrigerants.