1. Control panel functions

A. Manual activation of regeneration process
Immediate regeneration
Press the
it until the display screen shows a
flashing caption reading RECHARGE
NOW. The first phase of the
regeneration process will begin - filling
the brine tank with water. Subsequent
phases will be activated automatically.
Upon completion of the regeneration
process, the device's water softening
capacity will be restored.
Regenerate tonight
Press the
RECHARGE TONIGHT caption will
begin flashing. The regeneration
process will begin on the preset hour
(2.00 AM as default). In order to
cancel the regeneration process, it is
once more necessary to press (but
not to hold) the
RECHARGE TONIGHT caption will
disappear from the display screen.
During operation of the water softener, it
might be necessary to commence additional
manual regeneration. Such additional
regeneration process is required when:
actual water usage exceeds the planned
water usage (e.g. due to a visit of guests).
Such situation poses a threat that the resin's
ion exchange capacity will be exhausted
before the device activates the regeneration
process automatically,
the brine tank is short on salt (the brine
tank was not refilled with salt) - the brine
tank must be immediately topped up with
salt,
it is the first operation of the device
(commissioning of the device).
button (fig. 4) and hold
button (fig. 4). The
button. The
 Important notice!
The device does not generate
softened water during the course of
the regeneration process.