Maintenance and Troubleshooting
Figure 30 Connecting the Coaxial Cable
Figure 31 Connecting the Plastic Connector
Contact Information
28
11 Using a torque wrench, connect the coaxial cable connector to the
"F" connector on the MIU/register housing, tightening it to 15 foot-
pounds. See Figure 30.
12 Make sure the washer is properly seated. Connect the plastic
connector housing to the 3-lobed black plastic latch plate.
See Figure 31.
13 Slide the black conical-shaped gasket down the cable until it
engages the connector housing. See Figure 31.
14 Tighten the connector nut onto the threaded portion of the connec-
tor housing. This connection should be hand-tight. Do not use pli-
ers. See Figure 30.