13 Troubleshooting Guide
PROBLEM
Unit does not operate and
electronic display is blank.
No interior light
Electronic display is blank and
interior light is OFF with door OPEN.
Electronic display is blank and
interior light is ON with door OPEN.
Electronic display shows repeating,
randomly flashing symbols and
partial characters.
Electronic display shows:
0, 1 to 26, or 99.
Electronic display shows E3.
Electronic display shows one or
more of the following:
E1, E2, E4, E5, E6, E7, E8, E9, E10, P1.
Unit not cold enough. Check
temperatures (See OPERATION for
approximate temperatures).
Unit is too cold. Check temperatures
(See OPERATION for approximate
temperatures)
The unit frosts up.
POSSIBLE CAUSE
No electrical supply
Loose or burned out bulb
Unit is in blackout mode lighting
mode.
A display function has changed.
A factory control mode has been
inadvertently entered.
A factory control mode has been
inadvertently entered.
Door has been left open longer than
20 minutes.
The unit is displaying an error code.
Control set too warm
Airflow to front grille blocked
Dirty condenser coils
Door gasket not sealing properly
Inaccurate temperature reading
Control set too cold
High ambient temperatures or
humidity
Door gasket not sealing
2115WC and 2115WCOL2, 2175WC and 2175WCOL2
DANGER
ELECTROCUTION HAZARD
Never attempt to repair or perform maintenance on
the unit until the main electrical power has been
disconnected.
REMEDY
Plug unit in or check circuit breaker.
Tighten or replace bulb (See MAINTENANCE; LIGHT
BULB REPLACEMENT).
Exit blackout mode
(See OPERATION; INTERIOR LIGHT CONTROL).
Touch and hold the warmer temperature button and
touch and release the POWER button three times, then
release the temperature button. The display should
become visible.
Touch and hold the warmer temperature button and
touch and release the LIGHT button three times, then
release the temperature button to exit the factory
control mode. The set-point temperature should now
be displayed.
Repeatedly touch the warmer temperature button to
advance any number shown to 99 and touch and
release the LIGHT button. The set-point temperature
should now be displayed.
Close door completely. The set-point temperature
should now be displayed.
Record the error code(s) displayed and call for service.
Set control to a cooler setting (See OPERATION). Allow
24 hours for temperature to stabilize.
Airflow must not be obstructed to front grille (See
OPERATION).
Clean condenser (See MAINTENANCE; CONDENSER
CLEANING).
Door adjustment required (See MAINTENANCE; DOOR
ALIGNMENT CHECK AND ADJUSTMENT).
Properly check temperature (See OPERATION).
Set control to a warmer setting (See OPERATION). Allow
24 hours for temperature to stabilize.
Defrost unit manually (See MAINTENANCE;
DEFROSTING).
Adjust door (See MAINTENANCE; DOOR ALIGNMENT
AND ADJUSTMENT and DOOR REVERSAL).