NOTE: Refer to page 10 for instructions
on the range finder focusing dial that is
held on the bracket post by a screw
.
TRIGGER BUTTON HOUSING COMPLETE
(See figure
3)
.
The range finder plate complete (figure 6) can
be removed from the camera with the trigger but-
ton housing complete (figure 3) still attached to
it.
Remove the three trigger button housing screws
and remove the trigger button housing complete.
This will free the exposure indicator tube
,
which
is inserted in the range finder plate directly above
the red signal, and the exposure indicator tube can
be lifted off
.
Lift off the trigger button leak light washer.
If
necessary,
also remove the trigger buShIiig1eak
light washer, which is cemented to the range finder
plate-.--
COUNTER DIAL HOUSING COMPLETE
(See figure 4)
.
Remove the key knob screw and lift off the key
knob.
-
--Remove the three counter dial housing screws
and lift off the counter dial housing complete together
with the origin plate and the two origin plate screws.
CAM
STOP PAWL
Remove the key post spring washer
.
Note that
-this washer is placed on the key post with the con-
cave side upward
.
Some cameras also have a flat
key post spacing washer. This is to prevent the key
knob from wobbling as
it
is turned.
COUNTER DIAL ASSEMBLY AND SAFETY CON-
TROL STOP PAWL (See figure 5).
The range finder plate can be removed from the
camera with the counter dial assembly and the safety
control stop pawl still fastened to it. However, if
they are left on, the counter dial assembly must be
turned to any number except"O" in order to move
the end of the safety control stop pawl (figure 6)
away from the safety control cam complete.
Hold down the counter dial with the fingers
,
and
remove the counter knob screw (figure 5). Lift off
the counter knob washer, the counter dial assembly,
and the counter knob spring.
Unhook the straight end of the safety control
stop pawl spring (figure 6) from the projecting lug
on the range finder plate. Remove the safety con-
trol stop pawl stud. Lift off the safety control stop
pawl spring and the safety control stop pawl.
RANGE FINDER PLATE.
Remove the range finder plate screw (figure 6),
PLATE SCREW
LEVER PIN AND LEVER
Figure 6