WARNING
▪ Do not modify, disassemble, remove,
reinstall or repair the unit yourself as
incorrect dismantling or installation
may cause an electric shock or fire.
Contact your dealer.
▪ In case of accidental refrigerant
leaks, make sure there are no naked
flames. The refrigerant itself is
entirely safe, non-toxic and mildly
flammable, but it will generate toxic
gas when it accidentally leaks into a
room where combustible air from fan
heaters, gas cookers, etc. is present.
Always have qualified service
personnel confirm that the point of
leakage has been repaired or
corrected before resuming operation.
WARNING
▪ Do NOT pierce or burn refrigerant
cycle parts.
▪ Do NOT use cleaning materials or
means to accelerate the defrosting
process other than those
recommended by the manufacturer.
▪ Be aware that the refrigerant inside
the system is odourless.
WARNING
The appliance shall be stored in a
room without continuously operating
ignition sources (example: open
flames, an operating gas appliance or
an operating electric heater).
WARNING: MILDLY FLAMMABLE
MATERIAL
The refrigerant inside this unit is mildly
flammable.
WARNING
Stop operation and shut off the
power if anything unusual occurs
(burning smells etc.).
Leaving the unit running under such
circumstances may cause breakage,
electric shock or fire. Contact your
dealer.
RXYSA4~6A7V/Y1B
VRV 5-S system air conditioner
4P600329-1A – 2020.01
WARNING
The unit is equipped with a refrigerant
leak detection system for safety.
To be effective, the unit MUST be
electrically powered at all times after
installation, except for maintenance.
4
About the system
The VRV 5-S uses R32 refrigerant which is rated as A2L and is
mildly flammable. For compliance with the requirements for
enhanced tightness refrigerating systems and IEC60335-2-40 the
installer must take extra measures. For more information, see
"2.1 Instructions for equipment using R32
The indoor unit part of this VRV 5-S heat pump system can be used
for heating/cooling applications. The type of indoor unit which can be
used depends on the outdoor units series.
WARNING
▪ Do not modify, disassemble, remove, reinstall or repair
the unit yourself as incorrect dismantling or installation
may cause an electric shock or fire. Contact your
dealer.
▪ In case of accidental refrigerant leaks, make sure there
are no naked flames. The refrigerant itself is entirely
safe, non-toxic and mildly flammable, but it will
generate toxic gas when it accidentally leaks into a
room where combustible air from fan heaters, gas
cookers, etc. is present. Always have qualified service
personnel confirm that the point of leakage has been
repaired or corrected before resuming operation.
NOTICE
Do NOT use the system for other purposes. In order to
avoid any quality deterioration, do NOT use the unit for
cooling precision instruments, food, plants, animals, or
works of art.
NOTICE
For future modifications or expansions of your system:
A full overview of allowable combinations (for future
system extensions) is available in technical engineering
data and should be consulted. Contact your installer to
receive more information and professional advice.
4.1
System layout
a
b
c
c
d
d
f
a
Heat pump outdoor unit
b
Refrigerant piping
c
VRV direct expansion (DX) indoor unit
d
Remote controller in normal mode
e
Remote controller in alarm only mode
f
Remote controller in supervisor mode (mandatory in
some situations)
4 About the system
refrigerant" [ 4  9].
b
b
c
d
e
Installation and operation manual
15