TurboChef NGC-1007 Service Manual page 70

Ngc (tornado) oven
Table of Contents

Advertisement

CC
CLASS
CC
CLASS
CC
CLASS
N
L1
CT
AUX
ELE
IR
CT
HX
CT
MAG
DIAGRAM
LOAD
K1
230VAC
K2
TAPS
2
1
K3
2
PINOUT
1
ASSY
RELAY
57
SCHEMATIC
(UK)
NGC
AMPS
12
F1:
AMPS
12
F2:
AMPS
20
F3:
INPUT
WIRE
3
230VAC,
L1
N
43
HT
OHMS
14.4
WATTS
3000
IR
BOTTOM
A1
A2
30
BR
2
K4
+
31
32
A
29
RED
21
22
RD-19
1
38
HT
12
OHMS
13.1
11
WATTS
3300
RESET
MANUAL
ELEMENT
HX
OT1
15
BL
6
RED
K7
AN_RELAY
AG_F
M
B
WH-29
14
BL
NC
+
24V
A
NO
C
USE
NOT
O
D
5
RED
2
MAG
1
MAG
=
1-2
FAN
MAG
F
F
FA
FA
4
3
M1FA
M2FA
FT1
M1F
M2F
D1
D2
4
(-)
(+)
(+)
(-)
M1CD
M2CD
3
uF
.15
1
uF
.15
1
uF
.13
1
uF
.13
1
FT2
C1
C2
M1FC
M2FC
M1HV
M2HV
T1
T2
230VAC
=
1-2
TRANSFORMERS
HV
40
BLK
19
BLK
34
BL
SETUP
SWITCH
MONITOR
C
GRN/YEL
N
L1
BLUE
BROWN
40VSK6
HASE
1-P
FILTER
MI
E
SETUP
N
L1
NC
25
BLK
NO
1
1
1
NC
F3
2
F2
2
F1
FAN
EC
NO
2
B1
SECONDARY
B2
OR-6
K5
SSR
120°F
-
+
-
B
NO
C
OT2
WH-301
WH-28
IN6
P
IN6
P
WH-2
IN5
P
IN5
P
IN4
P
IN4
P
OR-61
IN3
P
IN3
P
WH-27
IN2
P
IN2
P
RD-19
IN1
P
IN1
P
QC3
B
A
4
6
2
3
5
1
BK-23
FILAMENT
K1
OR-11
QC2
QC1
B
A
NC
NC
C
C
NO
NO
212°F
212°F
4
SWITCHES
6
2
THERMO
MAG
3
5
1
ANODE
K2
G
SUPPLY
N
POWER
+V
RD-16
24VDC
-V
BK-20
L
B
A
4
6
2
6
OMMON
3
5
OK
S
STATU
5
4
COM
I/O
1
3
ABLE
EN
MONITOR
K3
CT
2
OMMON
MAG
1
0-10V
1
SPLICE
33
BL
OLD
-
INTERLOCKS
SAFETY
SECONDARY
NO
BK-21
C
NC
NO
PRIMARY
NC
NO
C
NC
CONNECTOR
CARD
SMART
NEW
-
INTERLOCKS
SAFETY
SWITCH
J6
MONITOR
P6
INTERLOCK
C
P4
PRIMARY
J4
NC
C
C
RJ11
NO
INTERLOCK
40
40
CC
CC
C(+)
RJ11
39
39
A(-)
38
38
EC
EC
THERMOCOUPLES
C(+)
37
37
A(-)
36
36
IR
IR
C(+)
35
35
A(-)
34
34
33
33
RTN)
MODULE
(VOLT
-24V
32
32
RTN)
(COM
(4)
BMSC
K-32
B
31
31
OUT)
(ENABLE
(3)
BMSC
WH-31
30
30
WH-301
OUT)
(CONV
(B-)
K4
29
29
RELAY
FAN
MAG
K7
WH-29
28
28
OUT
IR
BOTTOM
(-B)
K5
WH-28
27
27
WH-27
OUT)
FIL
(MAG
K1-B
26
26
25
25
(2)
COMM
BMSC
RD-25
24
24
OUT
0-10V
BMSC
RD-24
K-23
B
23
23
RTN
SW
THEMO
MAG
-24V
22
22
RTN
S&M
-24V
K-22
B
21
21
RTN
INTER
P
-24V
K-21
B
20
20
IN
PS
-24V
K-20
B
4
1
19
19
RD-19
18
18
5
2
17
17
16
16
IN
PS
+24V
RD-16
6
3
15
15
P5
14
14
CONNECTOR
13
13
IN
MODUAL
VOLT
6-PIN
OF
DRAWING
ASPEN
12
12
11
11
IN
SW
THERMO
MAG
R-11
O
10
10
IN
STATUS
HX
SEL
BMSC
OR-10
9
9
OK)
(STATUS
(9)
BMSC
R-9
O
8
8
IN
INTER
(NO)
SECONDARY
R-8
O
7
7
IN
INTER
(NO)
PRIMARY
R-7
O
6
6
IN
INTER
(NO)
MONITOR
OR-6
OR-6
5
5
4
4
3
3
2
2
CT
OUT)
(MAG
K2-B
WH-2
1
1
MAG
ODDS EVENS
8
BL
1
RED
1
C
I/O
IN
AC
V
2
00-240
2
3
MTR
C
I/O
MD
C
SPD
BLWR
BMSC
OUT
1
BLK
M1
PHASE
3
2
RED
M2
3
VAC
240
WHITE
M3
4
REEN
G
CONNECTOR
40-PIN
OF
DRAWING
APPLIED
POWER
WITHOUT
AND
OPEN
DOOR
WITH
OVEN
SHOWS
SCHEMATIC
1.
NOTES:

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents