Aalborg XFM Series Operating Manual page 45

Digital mass flow meters
Table of Contents

Advertisement

INDEX
GasIdentifer
100
FullScaleFlow
101
StdTemp
102
StdPressure
103
StdDensity
104
105
CalibrationGas
CalibratedBy
106
CalibratedAt
107
DateCalibrated
108
DateCalibrationDue
109
110
111
112
SensorTbl[0][Sensor Value]
113
SensorTbl[0][Flow]
114
SensorTbl[1][Sensor Value]
115
SensorTbl[1][Flow]
116
SensorTbl[2][Sensor Value]
117
SensorTbl[2][Flow]
118
SensorTbl[3][Sensor Value]
119
SensorTbl[3][Flow]
120
SensorTbl[4][Sensor Value]
121
SensorTbl[4][Flow]
122
SensorTbl[5][Sensor Value]
123
SensorTbl[5][Flow]
124
SensorTbl[6][Sensor Value]
125
SensorTbl[6][Flow]
126
SensorTbl[7][Sensor Value]
127
SensorTbl[7][Flow]
128
SensorTbl[8][Sensor Value]
129
SensorTbl[8][Flow]
130
SensorTbl[9][Sensor Value]
131
SensorTbl[9][Flow]
132
SensorTbl[10][Sensor Value]
133
SensorTbl[10][Flow]
134
Note: Values will be available for selected gas only.
Calibration Table: Gas Dependent Variables.
NAME
DATA TYPE
K_N
2
K_F1
K_F1
char[20]
Name of Gas [If not calibrated = "Uncalibrated"]
float
float
float
float
Name of Gas used for Calibration
char[20]
[If not calibrated=["Uncalibrated"]
char[20]
Name of person who performed actual calibration
char[20]
char[12]
char[12]
float
Gas Parameters: K-factor relative to N
float
float
uint
Index 0: Must be 120 (zero value) Do not Alter!
float
Index 0: Must be 0.0 (zero PFS) Do not Alter!
uint
10.0%F.S. A/D value from sensor [counts].
float
uint
20.0%F.S. A/D value from sensor [counts].
float
uint
30.0%F.S. A/D value from sensor [counts].
float
uint
40.0%F.S. A/D value from sensor [counts].
float
uint
50.0%F.S. A/D value from sensor [counts].
float
uint
60.0%F.S. A/D value from sensor [counts].
float
uint
70.0%F.S. A/D value from sensor [counts].
float
uint
80.0%F.S. A/D value from sensor [counts].
float
uint
90.0%F.S. A/D value from sensor [counts].
float
uint
100.0%F.S. A/D value from sensor [counts].
float
Flow in PFS. Should be 1.0 Do not Alter!
42
NOTES
Full Scale Range in l/min
Standard Temperature
Standard Pressure
Gas Standard Density
Name of Calibration Facility
Calibration Date
Date Calibration Due
Reserved
Reserved
Actual Flow in PFS [0.1].
Actual Flow in PFS [0.2].
Actual Flow in PFS [0.3].
Actual Flow in PFS [0.4].
Actual Flow in PFS [0.5].
Actual Flow in PFS [0.6].
Actual Flow in PFS [0.7].
Actual Flow in PFS [0.8].
Actual Flow in PFS [0.9].