GIGA-TMS MSR120 Series User Manual

Portable 3 tracks magnetic card reader with lcd

Advertisement

(Preliminary)
October 2004
REGISTERED TO ISO 9001:2000
8F, No.31, Lane 169, Kang-Ning St., Hsi-Chih Taipei Hsien, 221 Taiwan
Phone: (886) 2-2695-4214
FAX: (886) 2-2695-4213
www.gigatms.com.tw

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MSR120 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for GIGA-TMS MSR120 Series

  • Page 1 (Preliminary) October 2004 REGISTERED TO ISO 9001:2000 8F, No.31, Lane 169, Kang-Ning St., Hsi-Chih Taipei Hsien, 221 Taiwan Phone: (886) 2-2695-4214 FAX: (886) 2-2695-4213 www.gigatms.com.tw...
  • Page 2 Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of GIGA-TMS Inc. REVISIONS...
  • Page 3 Contents ....................Information ..........Technical And Operational Description ....................Connections ..................Card Data Format .................... Demo Software ....................Specifications ..............Communication Protocol ..............29 USB Driver Setup FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 4: Machine Type

    Information MSR120 Series Magnetic Swipe Reader MACHINE TYPE FUNCTION Muti-Battery F - MEM Single Cell NiHM / NiCd LR03 / AAA 512 KB 1 2 3 ALKALINE RS-232 2048 BEEP REC QUEUE AUTO MSR120 VER 1.2 RS232 Interface Muti-Battery F - MEM...
  • Page 5: Standard Package

    LR03-AAA ALKALINE 1.5V Battery Main unit ( BAT-T0010 ) ( MSR120 ) Chain Sling CD-ROM ( TM09F1001 ) ( DISK5216 ) RS232 Cable ( WAS-T0017 ) RS232 Cable for MSR120 series USB Cable for MSR120U series ( WAS-T0017 ) ( WAS-1571 )
  • Page 6 Technical And Operational Description Front Panel and Operations LCD Main Screen Operation LED Indicator Connector Operate Keypad Chain Sling hole Swipe Card Slot Battery Box Swipe Card Slot Swipe the card through the entire length of the slot to read. Operation LED Indicator When encountering erroneous input, defective card, misread,bad memory or incorrectly encoded data and so on, the device will turn on the ERROR indicator .
  • Page 7: Lcd Display

    Technical And Operational Description LCD Display Status Function Area Main Display Area Keypad Guidance Area PROMAG Status Function Area 1. Power Status Battery Power Supply Low Battery Power Supply External Power Supply 2. Decode Status Track 1 be Decoded Track 2 be Decoded Track 3 be Decoded 3.
  • Page 8: Function Menu

    Technical And Operational Description Function Menu Display Machine ID - 1-1. Machine ID 2 Character Display User Name - 1-2. User Name 16 Character 1. Profiles Set Display Mode - Track Series 1-3. Display Format Track Parallel Credit Card Set Back Light Duration - 2-1.
  • Page 9 Technical And Operational Description Display Information Exceptional Indicator LCD Display message Description Counterplot The RTC is malfunctioning Check RTC ! Setting Date and Time ( After swipe card ) The record already is full. Download Record FLASH Full ! ( After swipe card ) and Erase Record The record can’t write into the FLASH memory.
  • Page 10 Technical And Operational Description Operational Description 1. Powered by Battery “ “ For normal use, the unit is powered by battery. Push the Power Switch Button for about 2 seconds to turn on the “ “ unit. Also push the Power Switch Button for about 2 seconds to turn off the unit at Switch Mode.
  • Page 11: Replace Battery

    Technical And Operational Description Replace Battery Note: 1. Read the instructions on your device before replace new battery. 2. MSR120 can used Single-cell alkaline, nickel-cadmium (NiCd), or nickel-metal hydride (NiMH) Battery 1. Power turn off 4. Take new battery 2. Take the cover away 5.
  • Page 12 WAS-T0017 DSUB 9P POWER JACK DSUB 9P FEMALE PIN FUNCTION MINI USB 4P No use Connect to PC RS-232 PORT MSR120 Personal Computer External power Note: 1. When MSR120 is connected/disconnected with external power adapter, it would be turned On/Off automatically.
  • Page 13 Connections WAS-1571 USB 4P FEMALE PIN FUNCTION MINI USB 4P FUNCTION Connect to PC PORT MSR120 Personal Computer Note: 1. When MSR120 is connected/disconnected with USB port, it would be turned On/Off automatically.
  • Page 14 CARD DATA STRING TRACK 1 TRACK 2 TRACK 3 DATE & TIME & WEEK TRACK1 DATA TRACK2 DATA TRACK3 DATA DATE TIME WEEK TRACK1 DATA TRACK2 DATA TRACK3 DATA DATE TIME WEEK TRACK 1 CARD ID Track 1 IATA Bits Per Inch 1.
  • Page 15 STEP 1 : RUN MSR120 DEMO START MSR120 SOFTWARE STEP 2 : CHOOSE COM PORT (Do not choose TCP/IP) * BAUDRATE : 9600 BPS CHOOSE COM PORT STEP 3 :ENTER DATE/TIME TO GET DATE/TIME ( TO SHOW THE DATE&TIME IN MSR120 WHEN NEEDED) SHOW THE DATE&TIME IN MSR120 ENTER...
  • Page 16: Demo Software

    Demo Software STEP 4 : ENTER DATE/TIME TO SET DATE/TIME ( WHEN NEEDED) NOTE: MAKE SURE YOUR PC CURRENT TIME IS CORRECT BEFOR YOU SET PC TIME TO MSR120. SET DATE&TIME IN MSR120 OK ENTER SYNC STEP 5 : ENTER GET VERSION ( TO SHOW MSR120 FIRMWARE VERSON WHEN NEEDED) MSR120 FIRMWARE VERSION ENTER...
  • Page 17 Demo Software STEP 7 : ENTER Change Login ID TO Change Login ID (Login ID default setting is “0000”.) #2 ENTER NEW Login #1 ENTER Change Login ID STEP 8 : ENTER UPLOAD TO UPLOAD DATA #1 UPLOAD DATA #3 PRESS UPLOAD STEP 9 : ENTER SAVE TO SAVE DATA CURRENT...
  • Page 18 Demo Software STEP 10 : ENTER Write Card Write Card function only supple to MSR206 #1 ENTER #2 ENTER Write Card Auto Scan Write Card - Step 1: Select the data Click [Prev Record] and [Next Record] to select the data from upload data. All three tracks data can be edited by user if necessary.
  • Page 19 Demo Software Write Card - Step 3: Select Auto Next after Write The default setting of the [Auto Next after Write] check box is checked. User can click [Prev Record] or [Next Record] to select data that you need. Also, it allows user to uncheck [Auto Next] after write then select your own data.
  • Page 20 Demo Software STEP 12 : ENTER Database to erase the memory records of MSR120 (Note : Always [Save] the data before [Erase]) #2 CHOOSE ERASE DATABASE #1 ENTER DATABASE STEP 13 : ENTER Database to recovery the memory records of MSR120 (Note : Database must empty) CHOOSE RECOVERY DATABASE...
  • Page 21 Magnetic Stripe Card 1 2 3 TRACK 1 / IATA / 210 bpi / 79 Alphanumeric Characters TRACK 2 / ABA / 75 bpi / 40 Numeric Characters TRACK 3 / Thrift / 210 bpi / 107 Numeric Characters RS-232 RS232 Interface RS232 , Half-Duplex , 8N1 , 9600 bps USB Interface...
  • Page 22 GNET FEATURES Support TTY (TELE TYPE) OPERATION - Use TTY to send commands and messages. Simple handshaking - One enquiry one answer back. Multi-link capability Expandability - GNET provides 4 major functions: GNET 1. POLLING 2. LOGIN / LOGOUT V1.2 3.
  • Page 23 Communication Protocol Command Index Table Topic Command Contents Description Get Product Version SETTING Date,Time,Week Set Date,Time and Week Get Date and Time Get Number of Record DATABASE Number Read Record by Number Erase All Record Reply Index Table Topic Reply Contents Description Reply Information...
  • Page 24: Communication Protocol

    Communication Protocol 1. GET NUMBER OF RECORD : NUMBER CHKSUM NUMBER Record Count . 4 Bytes Width ( 0000h ~ 0800h ) EXAMPLE 000C The Total of Record Count : 12 2. READ RECORD BY NUMBER : NUMBER NUMBER DATA CHKSUM DATE TIME WEEK NUMBER...
  • Page 25 Communication Protocol 4. ERASE ALL RECORD : ( Physical Erase ) * ( Erase Duration : < 3 second ) EXAMPLE Erase all record ( Can’t use the “M” command to recover ) 5. RECOVER ALL RECORD : * ( Recover Duration : < 60 second ) EXAMPLE Recover all record 6.
  • Page 26: Set Password

    Communication Protocol 7. LOGOUT : EXAMPLE Logout 8. SET PASSWORD : PASSWORD CHKSUM PASSWORD New four digit password EXAMPLE 1234 Set new password : 1234 9. ENTER FIRMWARE MANAGEMENT MODE : EXAMPLE Enter firmware management mode...
  • Page 27: Set Date And Time

    Communication Protocol 10. SET DATE AND TIME : YYYYMMDDhhmmssw Week YYYY Year (2000 - 20xx ) Month (01 - 12 ) Date ( 01 - 31 ) Hour ( 00 - 23 ) Mintue ( 00 - 59 ) Second ( 00 - 59 ) Week ( 0 - 6 ) EXAMPLE 200005051230006...
  • Page 28 Communication Protocol EXAMPLE ROM-T0571 V1.03R0 ROM serial number = ROM-T0571 Firmware Version = 1.03 Modify times = 0 7. SET REGISTER : REGISTER PARAM CHKSUM REGISTER Register Address . 2 Bytes Width ( 00h ~ FFh ) PARAM Set Parameters of Register CHKSUM C + REGISTER + , + PARAM 8.
  • Page 29: Register Table

    Communication Protocol REGISTER TABLE Register Function Description Auto Off Duration(Low byte) 00~FFh (0~ 255 second ) Auto Off Duration(High byte) 00h: Auto Power Off Power Mode FFh: Switch Other: Real time Machine ID (High byte) 2 Characters Machine ID (Low byte) RTC cal.
  • Page 30: Usb Driver Setup

    USB Driver Setup Driver Software Installation - For WAS-1571 only 1.Connect WAS-1571 into the USB PORT of your Computer first. 2.Under Windows 98/2000/Me/XP,put DISK5216 into the cd-rom disk driver,it will automatically install the USB232/422/485 Driver Software into your Computer by following the steps as below: 1.
  • Page 31 USB Driver Setup 3. Select Searching locations for new driver Give the path location Select this Click Next 4. Windows is now ready to install the best driver Device name Path location Click Next...
  • Page 32 USB Driver Setup 5. Windows has finished installing the software Finish driver software installation Click Finish...
  • Page 33 USB Driver Setup 6. Make sure if the driver software installation is finished Connect WAS-1571 Cable into the USB port of the computer and then Click " Start " ->" Settings " -> " Control Panel " -> " System " ->" Device Manager "...
  • Page 34 Remove Driver Software How to remove USB232/422/485 Driver Software from your computer- Put DISK5216 into the CD-ROM drive of the computer and then find and execute Uninstall.EXE by following the steps as below: 1. Execute Uninstall.EXE program Execute Uninstall.EXE program 2.
  • Page 35 Remove Driver Software 3. Re-boot the Computer after remove program is done Click Yes or click "No" button for show as below :...

This manual is also suitable for:

Msr120Msr120u