Nomenclature; Product Character - Haier CA0035AANC Installation, Operation And Technical Manual

Air cooled module water chiller
Table of Contents

Advertisement

1. Nomenclature

1
2
Chiller
system
Compressor type
C
Hermetic scroll
Hermetic rotary
Hermetic single screw
Hermetic twin screws
Hermetic reciprocating
Hermetic absorption
Semi-hermetic scroll
Semi-hermetic single screw
Semi-hermetic twin screws
Semi-hermetic reciprocating J
Semi-hermetic absorption
Semi-hermetic centrifugal
Opened

2. Product character

a. Installation conveniently, no need the special machine room and water tower; can be installed on the
roof or out of the room. Widely application for cinema, hospital, hotel, school, commercial building, etc.
b. Utilize flexible scroll compressor. And adopts dual compressors in parallel technology. The master unit
will control both compressors run or stop due to the water outlet temp. Optimum refrigerant distribution
technique and minimum-deformation design. Adoption of rolling bearing and non-lubricated bearing.
Excellent heating effect at low temperature. Broad range of working temperature and suitability for high
condensation temperature.
c. Shell & Tube and U type inner grooved finned coil heat exchanger.
High efficient water side heat exchanger: in cooling, the water side heat exchanger is as evaporator; in
heating, it is as condenser. The freezed water flows outside of the pipe, and the refrigerant flows in the
pipe. Optimum design, reliable operation, reasonable structure, perfect performance.
d. Central control technology, indoor unit be connected with controller by dual core non-polar wire. The
indoor units can be controlled individually or simultaneously, more convenient, more energy saving.
One central air conditioning system can include max. 8 sets (65 series) or 16 sets (100 series) of
module unit. Through the dip switch on PCB you can set unit No. of every module unit, and every unit is
connected by RS485 port. Compact structure, convenient for electric installation.
e. Fan coil simultaneous control technology: indoor fan coil can be controlled individually or centrally.
Code Explanation for chiller
3 4 5 6
Capacity
Product type
(KW)
A
1 0 6 9
R22
Heat
B
0 2 3 7
pump
R407C B
C
0 0 1
2
R134a
D
R123
E
R22
F
Cooling
R407C N
only
G
R134a
H
R123
I
K
L
M
7
8
Unit
character
Air
100-115V/60Hz
A
cooled
A
Water
220-240V/50Hz
cooled
W
C
100V/50Hz
D
220V/60Hz
M
110V/50-60Hz
220V/50-60Hz
P
127V/60Hz
Q
240V/50Hz
110-220V/50-60H
z
380-400V/50Hz
415V/50Hz
HAIER CHILLER
9
Suitable voltage
Design number
Fixed
1
frequency
2
Inverter
3 DC inverter R-Z
4
5
6
7
8
9
N
M
10
A-G
H-Q

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ca0035mancCa0070aancCa0070manc