Amana APG14 M Series Installation & Operating Instructions Manual page 35

W/r410a single package gas-electric heating & cooling unit
Hide thumbs Also See for APG14 M Series:
Table of Contents

Advertisement

L1
SUPPLY VOLTAGE
208-230/1/60
CC
T1
L1
R
C
COMP
L1
S
H
LO
CM
HI
LO
VM
HI
EM
L1
1
L1
2
F
P1
TH
2
ALS
LS
HLO
1
HLI
R
3
PS
PSW
6
W1
PSW
W2
8
MVL
TO
9
M
MICRO
GV
MVH
Y2
7
HI
MVC
C
5
C
P2
COM
Y1
1
4
HPS
5
LPS
3
6
2
SOL
S OL
LO HEAT
HI HEAT
T2
TO
G
LO COOL
MICRO
T3
HI COOL
DIAGNOSTIC
STATUS
LED - RED
ON
NORMAL OPERATION
NO POWER OR
OFF
INTERNAL CONTROL
FAULT
IGNITION FAILURE
1 FLASH
PRESSURE SWITCH OPEN
2 FLASHES
PRESSURE SWITCH CLOSED
3 FLASHES
WITHOUT INDUCER ON
4 FLASHES
OPEN LIMIT SWITCH
5 FLASHES
FALSE FLAME DETECTED
COMPR. SHORT CYCLE DELAY
6 FLASHES
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
*PG1461***M41** WIRING DIAGRAM
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
COM PONENT LEGEND
L2
ALS
COMP
CM
CC
T2
CC
EM
FS
RCCF C
F
F
GND
GV
L2
HPS
L2
IIC
IGN
LS
L2
LPS
ODF
3
PS
L2
RCCF
SEE NOTE 2
RS
TR
SOL
TR
RS
VM
CC
T1
EM C
T4
CHECK
-
CHECK INPUT POWER
CHECK FUSE(S)
REPLACE CONTROL
GAS FLOW
GAS PRESSURE
GAS VALVE
FLAME SENSOR
CHECK PRESSURE SWITCH
CHECK TUBING
CHECK VENT MOTOR
CHECK PRESSURE SWITCH
CHECK WIRING FOR SHORTS
CHECK AUXILIARY LIMIT SW.
CHECK MAIN LIMIT SWITCH
CHECK ROLLOUT LIMIT SW.
CHECK GAS VALVE
CHECK FOR SHORTS IN
FLAME SENSOR WIRING
3 MIN COMP. SHORT
CYCLE DELAY
AUXILLARY LIMIT SWITCH
TH
TRANSFORMER HIGH
COMPRESSOR
HLO HI LIMIT OUTPUT
CONDENSER MOTOR
HLI
HI LIMIT INPUT
CONTACTOR
PSW
PRESSURE SWITCH
EVAPORATOR MOTOR
FLAME SENSOR
MVL
MAIN GAS VALVE LOW
FUSE
MVH
MAIN GAS VALVE HIGH
EQUIPMENT GROUND
MVC
MVC MAIN GAS VALVE COMMON
GAS VALVE
HIGH PRESSURE SWITCH
INTEGRATED IGNITION CONTROL
IGNITOR
LIMIT SWITCH
LOW PRESSURE SWITCH
OUTDOOR FAN
PRESSURE SWITCH
RUN CAPACITOR FOR COMPRESSOR/FAN
ROLLOUT SWITCH
SOLENOID (2ND STAGE COOL)
TRANSFORMER
VENT MOTOR
JUNCTION
TERMINAL
INTERNAL TO
INTEGRATED CONTROL
PLUG CONNECTION
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE
NOTES
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF
INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY).
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
3. USE COPPER CONDUCTORS ONLY
4. FOR 208V OPERATION, REMOVE BLUE LEAD FROM INDUCER LOW
TERMINAL. MOVE BLACK LEAD FROM PARK TERMINAL ONTO
INDUCER LOW TERMINAL. PLACE BLUE LEAD ON PARK TERMINAL.
5. USE NEC CLASS 2 WIRE FOR THERMOSTAT FIELD WIRING.
6. COMPRESSOR 2ND STAGE SOLENOID NOT PRESENT ON ALL MODELS.
DIAGNOSTIC
STATUS
LED - RED
LIMIT OPEN 5 TIMES IN SAME
7 FLASHES
CALL FOR HEAT
IDT/ODT OPEN
8 FLASHES
9 FLASHES
PSW/LOC OPEN
DIAGNOSTIC
STATUS
LED - AMBER
OFF
NO FLAME PRESENT
NORMAL FLAME PRESENT
ON
LOW FLAME SIGNAL
1 FLASH
2 FLASHES
FALSE FLAME DETECTED
35
FACTOR Y WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAGE
FI E LD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRE COD E
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PK PINK
PU PURPLE
RD RED
WH WHITE
YL YELLOW
EQUIPMENT GROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITER
CHECK
CHECK MAIN LIMIT SWITCH
CHECK AUXILIARY LIMIT SW.
CHECK JUMPER BETWEEN 1
AND 4 ON 6-CIRCUIT
CONNECTOR
CHECK OPTIONAL
REFRIGERANT SWITCHES
CHECK REFRIGERANT
SWITCHES FOR LOSS OF
CHARGE OR HIGH HEAD
PRESSURE
CHECK
-
-
GAS FLOW
GAS PRESSURE
GAS VALVE
FLAME SENSOR
CHECK GAS VALVE
CHECK FOR SHORTS IN
FLAME SENSOR WIRING
0140G04538-A