Raisecom Technology Co., Ltd. provides customers with comprehensive technical support and services. For any assistance, please contact our local office or company headquarters. Website: http://www.raisecom.com Tel: 8610-58963399 Fax: 8610-58963399-8886 Email: export@raisecom.com Address: No. 11, East Area, No. 10 Block, East Xibeiwang Rd, Haidian District, Beijing, P.R.China...
Page 3
Hardware version Software version ISCOM6820-GP A.00 or later V3.0 or later Related manuals The following table lists manuals and their contents related to the ISCOM6820-GP. Name Description ISCOM6820-GP Hardware This guide mainly introduces the hardware structure and Description cards, including product overview, components, fiber and cables, pluggable optical module, lookup table of LEDs, lookup table of weight and power consumption.
Page 9
Figures Figures Figure 1-1 Appearance of the ISCOM6820-GP chassis ..................2 Figure 1-2 Distribution of slots on the ISCOM6820-GP ..................2 Figure 2-1 Appearance of the MCUA ........................5 Figure 2-2 Appearance of the basic service card ....................6 Figure 2-3 Appearance of the GP16 card ....................... 6 Figure 2-4 Appearance of the EP16 card ........................
Page 11
ISCOM6820-GP (A) Hardware Description Tables Tables Table 1-1 Physical parameters of the ISCOM6820-GP ..................3 Table 2-1 Components of the ISCOM6820-GP ..................... 5 Table 2-2 Items on the hardware information label ....................8 Table 2-3 Interfaces on the MCUA card......................... 9 Table 2-4 Parameters of the Console interface .......................
Physical parameters 1.1 Introduction The ISCOM6820-GP is a next-generation, small-capacity, 2U, and plug-in Gigabit Passive Optical Network (GPON) Optical Line Terminal (OLT). It is oriented to industrial customers, providing rich features and flexible networking schemes to meet low-density and long- distance requirements for optical fiber access.
1.2 Appearance and slots 1.2.1 Appearance of chassis The ISCOM6820-GP is a cartridge device, which is flexible to be deployed. Dimensions of the chassis are: 442 mm (Width) × 236 mm (Depth) × 88 mm (Height) (without brackets). Figure 1-1 shows the appearance of the ISCOM6820-GP chassis.
Raisecom ISCOM6820-GP (A) Hardware Description 1 Overview Table 1-1 Physical parameters of the ISCOM6820-GP Parameter Description 442 mm (Width) × 236 mm (Depth) × 88 mm Dimensions (Height) (without brackets) DC model: 7.0 kg Weight Standard configuration AC model: 7.6 kg ...
AC power module (RPA1302-220D4805) DC power module (RPD1302-48D4805) Fan module (FANS380) 2.1 Overview 2.1.1 Classification The ISCOM6820-GP is composed of the following 5 types of components: Main control uplink card Basic service card Expansion service card ...
Raisecom ISCOM6820-GP (A) Hardware Description 2 Components Table 2-1 Components of the ISCOM6820-GP Component Name Description Main control uplink MCUA Control, management, aggregation, and card switching card Provide two 10GE uplink interfaces, 1 SNMP interface, and 1 Console interface (RJ45).
Figure 2-6 Appearance of the fan module 2.1.3 Hardware information label Hardware information of ISCOM6820-GP components is pasted on the eye-catching position of the Printed Circuit Board (PCB) to facilitate viewing it, as shown in Figure 2-7. Raisecom Proprietary and Confidential...
Raisecom ISCOM6820-GP (A) Hardware Description 2 Components Figure 2-7 Hardware information label on the ISCOM6820-GP The position of hardware information labels may be different because the layouts of elements are different, so search for it carefully. Table 2-2 lists items on the hardware information label.
2.2 Main control uplink card (MCUA) 2.2.1 Introduction The MCUA card is the main service uplink unit of the ISCOM6820-GP. It provides two 10GE optical interfaces (SFP+) and supports managing and maintaining the ISCOM6820-GP through the SNMP interface and Console interface.
Power consumption < 11 W 2.3 Basic service card (GPSC) 2.3.1 Introduction The GPSC is a GPON card of the ISCOM6820-GP, providing 16 GPON SFP interfaces. 2.3.2 Panel and slots The GPSC card can be only inserted into slot 3 of the ISCOM6820-GP.
ISCOM6820-GP (A) Hardware Description 2 Components 2.4 Expansion service card (GP16) 2.4.1 Introduction The GP16 card is the GPON interface card of the ISCOM6820-GP, providing 16 GPON SFP interfaces. 2.4.2 Panel and slots The GP16 card can be inserted into slot 4 only.
Power consumption 70 W 2.5 Expansion service card (GE16) 2.5.1 Introduction The GE16 card is the GE Ethernet service card of the ISCOM6820-GP, providing 16 GE interfaces. 2.5.2 Panel and slots The GE16 card can be inserted into slot 4 only.
32 W 2.6 AC power module (RPA1302-220D4805) 2.6.1 Introduction The RPA1302-220D4805 (hereinafter referred to as RPA1302) module is the AC power module of the ISCOM6820-GP. It supports the following features: Wide range of voltage input: 100–240 VAC Rated output voltage: -53.5 V and 5.5 V; rated output current: 5.5 A and 3 A ...
2.7 DC power module (RPD1302-48D4805) 2.7.1 Introduction The RPD1302-48D4805 (hereinafter referred to as RPD1302) module is the DC power module of the ISCOM6820-GP. It supports the following features: Wide voltage input: -38.4 to -57.6 VDC Rated output voltage: -48 V and 5.5 V; rated output current: 6 A and 3 A ...
Common mode: 1 kV 2.8 Fan module (FANS380) 2.8.1 Introduction The FANS380 module is the fan module of the ISCOM6820-GP. It supports the following features: Support fan monitoring. The system monitors the working status of the fan and an alarm is generated when the fan fails.
These two kinds of fiber are different in color. The yellow one is the single-mode fiber and the orange one is the multi-mode fiber. The ISCOM6820-GP can be connected to the Optical Distribution Frame (ODF) or optical interfaces of other devices through fiber.
Connect the SNMP of the ISCOM6820-GP to the NView NMS system. The Ethernet interface on the ISCOM6820-GP is adaptive to straight-through cable mode and crossover cable mode. So both kinds of Ethernet cables can be used. The Ethernet cable needs to be made on site.
CBL-ETH-RJ45/RJ45-2m/RoHS. 3.3 Configuration cable The configuration cable is used to connect the Console interface of the ISCOM6820-GP and the RS-232 serial interface of the maintenance console, and transmit configuration data signals. The maintenance console troubleshoots and maintains the ISCOM6820-GP through the Console interface.
3.4 DC power cable 3.4.1 Introduction The DC power cable supplies -48 VDC power from the power souring equipment to the power interface on the RPD1302 module of the ISCOM6820-GP, and then transmits power to the entire device. 3.4.2 Appearance The DC power cable is composed of the DC power connector and coaxial cable, as shown in Figure 3-9.
3.5.1 Introduction The AC power cable supplies 110/220 VAC power from the power souring equipment to the power interface on the RPA0601 module of the ISCOM6820-GP, and then transmits power to the entire device. Types of the AC power cable of the ISCOM6820-GP depend on different regional standards, as shown in Table 3-10.
3 Fiber and cables 3.6 Ground cable Connecting the ground cable properly is an important guarantee for lightning protection, anti-electric shock, and anti-interference. The ISCOM6820-GP must be connected to the ground cable correctly during installation, which helps avoid personal injury and equipment damage.
5–4 AWG (16–25 mm conducting wire The ISCOM6820-GP is delivered without the ground cable. If required, prepare or make the ground cable on site. The ground cable cannot be longer than 30 m and should be as short as possible;...
ISCOM6820-GP (A) Hardware Description 4 Pluggable optical modules Pluggable optical modules This chapter describes pluggable optical modules (Raisecom SFP modules are recommended) that could be used by the ISCOM6820-GP, including the following sections: 1000 Mbit/s SFP optical module ...
It is integrated with sending and receiving features. Figure 4-3 shows the appearance of the SFP+ optical module. Figure 4-3 SFP+ optical module The 10GE service interface on the ISCOM6820-GP supports the optical module of the following types: ...
Figure 4-4 shows the appearance of the PON SFP optical module. Figure 4-4 PON SFP optical module 4.3.2 Standard The GPON interface on the ISCOM6820-GP supports the optical module compliant with the Class B+, Class C+, and Class C++ standard. Raisecom Proprietary and Confidential...
Raisecom ISCOM6820-GP (A) Hardware Description 5 Lookup table of LEDs Lookup table of LEDs Table 5-1 lists LEDs of the ISCOM6820-GP. Table 5-1 LEDs of the ISCOM6820-GP Status Description Green Power LED Green: the power supply is working properly.
ISCOM6820-GP (A) Hardware Description 6 Lookup table of weight and power consumption Lookup table of weight and power consumption Table 6-1 lists weight and power consumption of the ISCOM6820-GP. Table 6-1 Weight and power consumption of the ISCOM6820-GP Component Parameter ...