Perfect Prime TC0301 Instruction Manual

Thermometer

Advertisement

Quick Links

Datalogger Thermometer
TC0301
Instruction Manual

Advertisement

Table of Contents
loading

Summary of Contents for Perfect Prime TC0301

  • Page 1 Datalogger Thermometer TC0301 Instruction Manual...
  • Page 2: Table Of Contents

    CONTENTS 1. Introduction ....................2 2. Specifications ..................2 - 4 3. Symbol Definition and Button ............. 5 - 6 3.1 Location ....................6 4. Operation Instructions ................ 7 - 13 4.1 Power-Up ....................7 4.2 Connecting the Thermocouples .............. 7 4.3 Selecting the Temperature Scale .............
  • Page 3: Introduction

    1. INTRODUCTION/ 2. SPECIFICATIONS INTRODUCTION This instrument is a digital thermometer for use with any K-type thermo- couple as temperature sensor. Temperature indication follows National Bureau of Standards and IEC584 temperature/voltage table for K-type thermocouples. SPECIFICATIONS NUMERICAL DISPLAY: 4 digital liquid crystal display MEASUREMENT RANGE: -200°C ~ 1370°C -328°F ~ 2498°F RESOLUTION:...
  • Page 4: Specifications

    2. SPECIFICATIONS ACCURACY: AT 23 ± 5°C Range Accuracy -200°C ~ 200°C ±(0.3% reading + 1°C) 200°C ~ 400°C ±(0.5% reading + 1°C) 400°C~1370°C ±(0.3% reading + 1°C) -328°F ~ -400°F ±(0.5% reading + 2°F) -200°F ~ 200°F ±(0.3% reading + 2°F) 200°F ~ 400°F ±(0.5% reading + 2°F) 400°F ~ 2498°F...
  • Page 5 2. SPECIFICATIONS DIMENSION: 184×64×30mm WEIGHT: 210g Approx.(7.4oz) ACCESSORY: K Type Bead Probe, Battery, Carrying Case, Instruction Menu. OPTION: Soft Ware Package ( Program, RS232 Connection Cable) , AC Adapter. POWER REQUIREMENT: 9 Volt Battery, NEDA 1604 or JIS 006P or IEC6F22 BATTERY LIFE: Approx.
  • Page 6: Symbol Definition And Button

    3. SYMBOL DEFINITION AND BUTTON LOCATION Main Display Second Display : This indicates that the minus temperature is sensed. : Centigrade and Fahrenheit indication. °C °F : Thermocouple Type Indication : This indicates that the display data is being hold. HOLD : The Maximum value is now being displayed.
  • Page 7: Location

    3. SYMBOL DEFINITION AND BUTTON LOCATION T1 K type temperature MAX MIN Average control sensor connector button T2 K type temperature °C, °F control button sensor connector O set calibration screw LCD display 11 Digital output connector ON/OFF button AC power adapter connector HOLD button Tripod connector T1,T2,T1-T2 control button...
  • Page 8: Operation Instructions

    4. OPERATION INSTRUCTIONS 4.1 POWER UP Press the key to turn the thermometer On or OFF. 4.2 CONNECTING THE THERMOCOUPLES For measurement, plug the thermocouple into the input connectors. 4.3 SELECTING THE TEMPERATURE SCALE When the meter was rst powered on, the default scale setting is set at Celsius (°C) scale.
  • Page 9: Max/Min/Avg Operation

    4. OPERATION INSTRUCTIONS 4.7 MAX/MIN/AVG OPERATION FOR MAIN DISPLAY When one presses the button the meter will enter the MAX/MIN mode. Under this mode the maximum value, minimum value and average value of latest 8 data is kept in the memory simultaneously and updated with every new data.
  • Page 10: Low Battery Condition

    4. OPERATION INSTRUCTIONS 4.9 LOW BATTERY CONDITION When the battery voltage is under proper operation requirement, symbol will show on the LCD and the battery need to be replaced with new one. 4.10 CALIBRATION POINT Room Temperature 23 ± 3°C input Adjust VR Tolerance...
  • Page 11 4. OPERATION INSTRUCTIONS RS232 command Function Remarks Ask for model No. Send 4 bytes K(ASC 4BH) Ask for main display Send 22 bytes D(ASC 44H) Range, Data, Unit Ask for secondary Send 22 bytes B(ASC 42H) display Range, Data, Unit Ask Status Send 13 bytes S(ASH 53H)
  • Page 12 4. OPERATION INSTRUCTIONS Data: ±9999.9,-OL,OL ( 7bytes include polarity and decimal point), Unit: C,F(5bytes) When the meter receive the D command, it will send : Range□Data□Unit. ( where □ represent space (ASC(20H) ) For example: T1□□□□□□-199.9□□C□□□□ (0x13) represent T1,- 199.9°C, The total byte number should be 7+1+7+1+5+chr(13)=22Bytes •...
  • Page 13 4. OPERATION INSTRUCTIONS • COMMAND A 1nd BYTE: The rst byte is the start byte , it value is 2. 2nd BYTE: bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 Low Bat Hold MAX/AVG/MIN bit 2 bit 1 bit0 0 → normal mode 1 →...
  • Page 14 4. OPERATION INSTRUCTIONS bit7 bit6: 00→Main window is T1-T2,sub window is T1 01→Main window is T1-T2, sub window is T2 10→Main window is T1, sub window is T2 11→Main window is T2, sub window is T1 4th BYTE: rst two BCD code of main window value. 5th BYTE: last two BCD code of main window value 6th BYTE:...
  • Page 15 CUSTOMER SERVICE INQUIRIES Your emails are important to us so we strive to reply all hours. In exceptional cases, inquiries and emails within we may require more time to respond. Thank you for your understanding. For more information about our products and services, please send us an email: cs@perfectprime.com For B2B or project-based application, please send an email:...