ZFR1811 Wireless Field Bus Router
Installation Instructions
MS-ZFR1811-x
Application
Use the ZFR1811 Wireless Field Bus Router only to
provide an input to equipment under normal
operating conditions. Where failure or malfunction of
the ZFR1811 Router could lead to personal injury or
property damage to the controlled equipment or
other property, additional precautions must be
designed into the control system. Incorporate and
maintain other devices, such as supervisory or
alarm systems or safety or limit controls, intended to
warn of or protect against failure or malfunction of
the ZFR1811 Router.
IMPORTANT: The ZFR1800 Series Wireless Field
Bus System is not designed or intended for use in
mission-critical or life/safety applications.
A ZFR1811 Wireless Field Bus Router is used with
Field Equipment Advanced Application Controllers
(FACs), Field Equipment Controllers (FECs), Input/
Output Modules (IOMs), and Variable Air Volume
Modular Assembly (VMA) Series field controllers.
The ZFR1811 Router provides a wireless interface
between:
a field controller and the supervisory controller (by
means of a ZFR1810 Coordinator)
a field controller and associated WRZ Series
Wireless Room Sensors
Additionally, the ZFR1811 Wireless Field Bus Router
can be used as a repeater in WRZ-7860-0 One-to-One
Wireless Room Temperature Sensing System. For
more information, refer to the WRZ Series One-to-One
Wireless Room Sensing System Technical Bulletin
(LIT-12011641).
Up to nine WRZ Series Sensors can be associated
with a single field controller. In multi-sensor
applications, the ZFR1811 Router passes all the
sensor data to an FAC, FEC, IOM, or VMA controller,
which can be configured to either average the sensors'
input or select the highest or lowest sensed condition
for control of the target zone.
Refer to the
QuickLIT Web site
A ZFR1811 Router is powered directly from the
connected field controller's 15 VDC output.
The Router can also be powered by the power supply
in the Repeater Accessory Kit to serve as a
stand-alone repeater, extending the range of the
communications within the wireless mesh network.
Refer to the ZFR1800 Series Wireless Field Bus
System Technical Bulletin (LIT-12011295) or the
ZFR1800 Series Wireless Field Bus System Quick
Reference Guide (LIT-12011630) for information on
commissioning and configuring a ZFR1800 Series
Wireless Field Bus System for operation.
ZFR1811 Wireless Field Bus Router Installation Instructions
Part No. 24-10325-10, Rev. L
Issued April 2016
for the most up-to-date version of this document.
1

Advertisement

Table of Contents
loading

Summary of Contents for Johnson Controls ZFR1811

  • Page 1 A ZFR1811 Router is powered directly from the connected field controller’s 15 VDC output. Use the ZFR1811 Wireless Field Bus Router only to The Router can also be powered by the power supply provide an input to equipment under normal in the Repeater Accessory Kit to serve as a operating conditions.
  • Page 2: North American Emissions Compliance

    This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • Do not drop the ZFR1811 Router or subject it to physical shock. 1. This device may not cause harmful interference, Dimensions See Figure 1 for physical features and dimensions of 2.
  • Page 3: Location Considerations

    Do or other metal obstructions by at least 50 mm not mount the ZFR1811 Router in a horizontal (2 in.). Do not mount the ZFR1811 Router in a orientation. See Figure 2. horizontal orientation. See Figure 2 and Figure 3.
  • Page 4 Wiring with an FEC or VMA16 Series Field Controller Connect the ZFR1811 Router to the field controller as shown in Table 2. This connection provides both power and communication to the ZFR1811 Router. Note: When using a field controller in a wireless field bus network, ensure that the DIP switch for Address 128 is set to the ON position.
  • Page 5 IOMs cannot be used in wireless mode to extend the IO of a field controller. You must always hardwire IOMs to their host field controller. Do not connect any device to the SA Bus/FC Bus terminal block when using the IOM with a ZFR1811. For further information on how to set up a field...
  • Page 6 (RJ-12 Modular Jack) Power (15 VDC) Bus and Power Common Power (15 VDC) Bus and Power Common SA or FC Bus SA or FC Bus + Figure 5: Pin Number Assignments for RJ-12 Jack ZFR1811 Wireless Field Bus Router Installation Instructions...
  • Page 7: Setup And Adjustments

    IMPORTANT: On the MS/TP Address switch block of the associated FEC/IOM/VMA16 Field Controller, set switch 128 to ON for use with a ZFR1811 Router. Set the PAN Offset value of the ZFR1811 Router using the DIP switches (located on the back of the cover) to configure the ZFR1811 Router to communicate on the wireless mesh network.
  • Page 8: Troubleshooting

    See Table 3. Figure 1) along with the information in Table 3 to troubleshoot the ZFR1811 Router. Note: The Signal Strength LEDs on all the ZFR1811 routers in a network extinguish after approximately Wireless Signal Strength...
  • Page 9 The Signal Strength LEDs on all the ZFR1811 Routers in a network extinguish after approximately 2 hours of normal operation, making the ZFR1811 less distracting when installed in an open area. To re-enable the ZFR1811 LEDs for troubleshooting purposes, perform a scan using the ZCT or push the Network Optimize/Reform Push Button on the ZFR1810 Coordinator.
  • Page 10: Repair Information

    Product Description Number MS-ZFRRPT-0 Optional Repeater Accessory for use with ZFR1811 Router as a repeater. Includes power supply (20–28 VAC or 16-30 VDC input power and 12 VDC output power), and 4 x 4 in. electrical box with cover. WRZ-SST-120 Wireless Sensing System Tool.
  • Page 11 The performance specifications are nominal and conform to acceptable industry standard. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products.

Table of Contents