Nameplate Information; Application Range - Emerson Copeland 4MF-13X User Manual

Semi-hermetic compressor stream for refrigeration applications
Hide thumbs Also See for Copeland 4MF-13X:
Table of Contents

Advertisement

Nameplate Information

All important information for identification of the compressor is printed on the nameplate located below the compressor oil pump.
The type of refrigerant used should be stamped on the nameplate by the installer.
The date of production indicates the year and week of production. The year and month of production are also part of the serial number
(Jan. = A, Feb. = B, ... Dec. = L).

Application Range

Qualified Refrigerants and Oils
IMPORTANT
It is essential that the glide of refrigerant blends (primarily R407C) is carefully considered when adjusting pressure and
superheat controls.
Oil recharge values can be taken from Copeland
Qualified Refrigerants
Copeland
Brand Products
Standard Oil
Servicing Oil
Table 2: Qualified refrigerants and oils for recharging and topping up
To Recharge:
When the compressor is completely empty of oil, the amount of oil to be "recharged" is typically 0.12 litre less than the original oil
charge (oil will already be around the system).
To Top up:
During commissioning, planned maintenance or servicing, add oil so that the compressor oil level is correct.
Figure 3
brand products Selection Software on www.EmersonClimateAsia.com
R404A, R407A, R407C, R407F, R134a, R507
Emkarate RL 32 3MAF
Emkarate RL 32 3MAF
Mobil EAL Arctic 22 CC
R22
Karamay 32BYMO
Karamay 32BYMO, Suniso 3GS
Shell 22-12, Texaco Capella WF32
11

Advertisement

Table of Contents
loading

Table of Contents