Service manual: XY AXES CALIBRATION 3DGence DOUBLE...
Page 2
XY axes CALIBRATION OF 3DGENCE DOUBLE 1. Prepare calibration model .gcode using 3DGence Slicer. The Dimmension_Calibration.stl model is available on www.3dgence/support in Your files category (Your files category is available after creating an account and registering the device). 2. Turn on the printer.
Page 3
9. Print the model again, then repeat the actions until the measurements oscillate between 99,95 – 100,05 (the tolerance ± 0,05) and the difference between the measurements will be around 0 – 0,05. 05.2018 3DGence DOUBLE | Support: +48 438 98 64 | www.3dgence.com/support...