MMI structure
Relay operation
status indication
lamp
① Status LED
② Function key
③ Direction key
④ Remote /
Local
⑤ CB
CLOSE/OPEN
How to operate CB Close/Open
X 1 times
(Switch to Local(In site operation) status
and confirm)
* When it is not operated for 15
minutes while the password has
been released, the lamp on the LCD
screen will be off and it will be locked
again (But checking correction
value/measurement value is still
available regardless of the password)
* When approving the DC power again
after turn it off, it requires the
password input.
(Indicated approximately for 3~4 sec)
① Status LED
Operation Power
status indication
: Lights up when
operation power is
approved.
Indicates communication
status with
monitoring department
: Flickering when
sending/receiving data
Indicates abnormal
status by internal
selfdiagnosis
: Lights up when an
error occurs
Indicates operation
status of the relay
: Flickering in Pick-up
status Lights up in
Trip status
Close
Open
Close
1) It works by pressing the Close / Open
button of the relay twice.
2) ⑤
operation should be conducted while
the ④ is indicated on the indication screen.
X 3 times
3) When the password is released, ② , ③
processes will be skipped and Close /
Open operation will be conducted through
① , ④ and ⑤ processes.
4) The password is required only when
inputting correction values, conducting
controls, and rebooting.
※
Checking status and measurement value monitoring
will be still available without password.
CT/PT input
①
Go to SYSTEM CONFIG menu on the initial screen.
②
Then go to RELAY CONFIG menu in the SYSTEM CONFIG.
③
Generate a cursor, and put the value to where you want to input.
② Function key
The confirmation for the setting values can be done by following
※
: Display simple single line
diagram and measurement value
(After confirm, press
: Save settings
: Delete accumulation
value (Wh, Vo, Io,
Event/Fault History)
: Set the relay operation status
indication lamp
: Relay Reset button
③ Direction key
(Initial monitor)
: Confirmation button, back to
the detail settings
: Cancel button, back to the
previous screen
: Cursor movement button
: Change the correction
values or relay elements. ( )
Operation
Open
5-1
~
process.
①
④
to go back to the initial screen.)
X 4 times
Change the
value by using
and move
the cursor with
Put
in the [ ]
by using
and move
the cursor with
Press
to generate
a cursor.
When input is over, save the changed
value by pressing
to go back to the preveious screen
(
).
,
.
,
.
, and then press
Need help?
Do you have a question about the GIPAM 2000 and is the answer not in the manual?