White Harness P/N 45263
22
Separate three of the cables, 41474, 45202 and 45203. These
three cables will go down either the yellow or white column,
depending on which side the customer prefers to install their
operator side. These cables should only be pulled out 12 to 14
inches out of the hole where the touchpad is to be mounted.
Align the harness starting point with the mark point and route the
three cables that have been separated through their corre-
sponding column and out of the keypad hole.
Route the Yellow harness through the yellow column.
Tie the loose interlock cable onto the Blue harness and run them
both down the blue column.
(Packed in Upper Cabinet Kit P/N 45251)
Mark the white harness breakout point as indicated.
WHITE HARNESS
FIRST BREAK OUT
7.5"
11"
Lay the white harness breakout point with its starting point.
Run two cables from the Red harness, 45211 (SW3-P1) and 45211
(PL2-J3) and tie them into the white harness.
The best method to tie the extra cables into the white harness is
to let the harness hang from the side of the Omnivision an cinch
the extra cables with tie wraps every 12 inches.
Run the white harness down the column.
YELLOW COLUMN