NI 5742 Getting Started Manual

32-channel signal generator

Advertisement

Quick Links

GETTING STARTED GUIDE
NI 5742
32-Channel Signal Generator
Note
Before you begin, install and configure your chassis and controller.
The NI 5742 is a 32-channel, 1 MS/s analog output adapter module designed to work in
conjunction with your NI FlexRIO
The NI 5742 features 16-bit analog output channels that can be configured to drive either
unipolar or bipolar output.
This document explains how to install and connect signals for the NI 5742R, which is
composed of a FlexRIO FPGA module and the NI 5742.
Caution
manner not described in this document.
The following figure shows an example of a properly connected FlexRIO device.
NI FlexRIO
Adapter Module
Contents
Installing the NI FlexRIO Adapter Module.............................................................................. 2
Electromagnetic Compatibility Guidelines............................................................................... 3
How to Use Your FlexRIO Documentation.............................................................................. 4
FlexRIO Documentation Locations.................................................................................. 5
Verifying the System Requirements..........................................................................................6
Unpacking the Kit..................................................................................................................... 6
Preparing the Environment....................................................................................................... 7
FPGA module.
The protection provided by the NI 5742 can be impaired if it is used in a
Figure 1. FlexRIO Device
NI FlexRIO
+
FPGA Module
=
NI FlexRIO Device

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5742 and is the answer not in the manual?

Questions and answers

Summary of Contents for NI 5742

  • Page 1: Table Of Contents

    NI 5742 32-Channel Signal Generator Note Before you begin, install and configure your chassis and controller. The NI 5742 is a 32-channel, 1 MS/s analog output adapter module designed to work in ™ conjunction with your NI FlexRIO FPGA module.
  • Page 2: Installing The Ni Flexrio Adapter Module

    Refer to the getting started guide for your FlexRIO FPGA module for FlexRIO FPGA module installation instructions. Gently insert the guide pins and the high-density card edge of the NI FlexRIO adapter module into the corresponding connectors of the NI FlexRIO FPGA module, as shown in the figure below.
  • Page 3: Electromagnetic Compatibility Guidelines

    The connection may be tight, but do not force the adapter module into place. Tighten the captive screws on the NI FlexRIO adapter module to secure it to the NI FlexRIO FPGA module. NI recommends using the laser-tipped screwdriver (part number 748677-01) included in the NI 5742 packaging.
  • Page 4: How To Use Your Flexrio Documentation

    NI FlexRIO System You New to LabVIEW FPGA in LabVIEW FPGA LabVIEW FPGA Module Module Module? LabVIEW FPGA NI FlexRIO LabVIEW Module Help Help Examples NI FlexRIO Adapter Module Development Kit User Manual 4 | ni.com | NI 5742 Getting Started Guide...
  • Page 5: Flexrio Documentation Locations

    LabVIEW Examples Available in NI Example Finder. In Contains examples of how to LabVIEW, click Help»Find run FPGA VIs and Host VIs Examples»Hardware Input and on your device. Output»FlexRIO. NI 5742 Getting Started Guide | © National Instruments | 5...
  • Page 6: Verifying The System Requirements

    Verifying the System Requirements To use the NI 5742, your system must meet certain requirements. For more information about minimum system requirements, recommended system, and supported application development environments (ADEs), refer to the readme, which is available on the software media or online at ni.com/updates.
  • Page 7: Preparing The Environment

    Preparing the Environment Ensure that the environment you are using the NI 5742 in meets the following specifications................Operating temperature 0 °C to 55 °C (IEC 60068-2-1, IEC 60068-2-2) ................Operating humidity 10% to 90% RH, noncondensing (IEC 60068-2-56) ................
  • Page 8: Installing The Ni Flexrio Devices

    Refer to the getting started guide for your FlexRIO FPGA module for FlexRIO FPGA module installation instructions. Gently insert the guide pins and the high-density card edge of the NI FlexRIO adapter module into the corresponding connectors of the NI FlexRIO FPGA module, as shown in the figure below.
  • Page 9: Connecting Cables

    The connection may be tight, but do not force the adapter module into place. Tighten the captive screws on the NI FlexRIO adapter module to secure it to the NI FlexRIO FPGA module. NI recommends using the laser-tipped screwdriver (part number 748677-01) included in the NI 5742 packaging.
  • Page 10: Removing The Adapter Module

    Store the module in the original antistatic packaging when not in use to avoid damage. Installing Accessories The NI SMB-2153 is a breakout box accessory for debugging your NI 5742. The NI part number for the NI SMB-2153 is 189408F-07L.
  • Page 11: Appendix A: Ni 5742 Features

    1 MS/s 16-Bit Analog Output Caution To avoid permanent damage to the NI 5742, disconnect all signals connected to the NI 5742 before powering down the module, and connect signals NI 5742 Getting Started Guide | © National Instruments | 11...
  • Page 12 Caution Connections that exceed any of the maximum ratings of any connector on the NI 5742 can damage the device and the chassis. NI is not liable for any damage resulting from such connections. Figure 6. NI 5742 Analog Output Connector Pinout...
  • Page 13: Block Diagrams

    The AUX I/O connector accepts a standard, third-party HDMI cable, but the AUX I/O port is not an HDMI interface. Do not connect the AUX I/O port on the NI 5742 to the HDMI port of another device. NI is not liable for any damage resulting from such signal connections.
  • Page 14: Appendix B: Interfacing With The Ni 5742

    The interface between the NI 5742 CLIP and LabVIEW FPGA in the following figures. If you are using an NI FlexRIO FPGA module with a Virtex-5 FPGA, refer to the following figure, which shows the relationship between the CLIP and an FPGA VI configured for use with a Virtex-5 FPGA target.
  • Page 15 DRAM 0 DRAM 1 If you are using an NI FlexRIO FPGA module with a Kintex-7 FPGA, refer to the following figure, which shows the relationship between the CLIP and an FPGA VI configured for use with a Kintex-7 FPGA target.
  • Page 16 DRAM NI 5742 CLIP The NI 5742 provides access to thirty-two 16-bit analog output channels, eight bidirectional DIO channels, four bidirectional PFI channels, and one bidirectional trigger line. The following figure shows the relationship between the NI 5742 and LabVIEW FPGA.
  • Page 17: Clocking

    Clocking The NI 5742 clock source controls the sample rate and other timing functions on the device. The following table contains information about the possible NI 5742 clock sources. Table 3. NI 5742 CLIP Clock Sources Clock Frequency DAC Clock...
  • Page 18: Worldwide Support And Services

    . You can find information about patents.txt ni.com/patents end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at for the National Instruments global trade compliance policy and ni.com/legal/export-compliance...

Table of Contents