  • Page 1 OPENVISION™ OVDX-NDT-70 HARDWARE MANUAL...
  • Page 2: Table Of Contents

    Installation of Handle Extension Assembly ........................21 Monitor ....................................23 Imager Shield ..................................25 Maintenance..................................26 Troubleshooting..................................27 QSA Global, Inc. Contact Information ..........................28 Appendix 1: Parts List................................29 Page 2 of 29 QSA Global, Inc. ...
  • Page 3: Introduction

    32 in. x 20.5 in. x 12.5 in Shipping Dimensions (82 cm x 52 cm x 32 cm) FDA Accession # 1680071-000 Page 3 of 29 QSA Global Inc.  40 North Avenue Burlington, MA 01803  888.272.2242  781.272.2000 ...
  • Page 4  US Mil Spec MIL-PRF-31013  CE END 166 FTKN Battery/Charger California Energy Commission Underwriters Laboratory for Canada and U.S. Page 4 of 29 QSA Global, Inc.  40 North Avenue Burlington, MA 01803  888.272.2242  781.272.2000  F: 781.359.9179 ...
  • Page 5: Safety Precautions

    Keep the OpenVision™ controller locked while assembling the system and when not being used to perform scanning. Locked is defined as the controller key switch in the Off position with the key removed. Store the key in a secure location. Page 5 of 29 QSA Global Inc.  40 North Avenue Burlington, MA 01803 ...
  • Page 6: Operating Conditions

    A Class 2 laser is not a skin or materials burn hazard. NEVER aim any laser towards an aircraft or vehicle in motion. Page 6 of 29 QSA Global, Inc.  40 North Avenue Burlington, MA 01803 ...
  • Page 7: Getting To Know Your Openvision™ Digital X-Ray (Ovdx) System

    415100 OVDX Main Housing Assembly 415600 Backscatter Shield Assembly 415410 OVDX Monitor Assembly (optional) Figure 1 OVDX Assembly Description Page 7 of 29 QSA Global Inc.  40 North Avenue Burlington, MA 01803  888.272.2242  781.272.2000  F: 781.359.9179 ...
  • Page 8: Ovdx Main Housing Details

    Trigger Handle Assembly 415130 Trigger Adapter Port Cover Strain Relief for HDMI Connection 2 Figure 2 OVDX Main Housing Assembly (Item # 415100) Page 8 of 29 QSA Global, Inc.  40 North Avenue Burlington, MA 01803  888.272.2242 ...
  • Page 9: Principles Of Operation

    Time calculations (as used in gamma-ray radiography exposure) are not needed for X-ray radiography. To determine exposure requirements, start on the lowest kV/mA settings and adjust to achieve the desired image quality. Page 9 of 29 QSA Global Inc.  40 North Avenue Burlington, MA 01803 ...
  • Page 10: Radiation Zones

    Actual measurements can vary based on the material being scanned and its geometry. To minimize operator exposure, QSA recommends using a backscatter shield assembly (Item # 415600) with your OVDX. Page 10 of 29 QSA Global, Inc.  40 North Avenue Burlington, MA 01803 ...
  • Page 11: Backscatter Radiation Levels

    .040” [1 mm] thick Aluminum Cladding  70 kV @ 0.17 mA (maximum power) See the following section for additional information on backscatter. Page 11 of 29 QSA Global Inc.  40 North Avenue Burlington, MA 01803  888.272.2242 ...
  • Page 12: Backscatter

    (Figure 5) will help reduce the amount of backscatter when firmly applied to the scanning surface as shown in Figure 7. Figure 5 Backscatter Shield (Item # 415600) Page 12 of 29 QSA Global, Inc.  40 North Avenue Burlington, MA 01803 ...
  • Page 13 Figure 6 Example of Backscatter Figure 7 OVDX with backscatter shield properly positioned against insulation sheathing. Page 13 of 29 QSA Global Inc.  40 North Avenue Burlington, MA 01803  888.272.2242  781.272.2000  F: 781.359.9179  qsa-global.com...
  • Page 14: Operation

    Unlock main housing by pressing red circular release button and unfold to operating position: Operating Position Red Button Figure 8 Unlock Main Housing Page 14 of 29 QSA Global, Inc.  40 North Avenue Burlington, MA 01803  888.272.2242 ...
  • Page 15 Install Backscatter shield by lining up grooves and slide/lock into position shown, and position handles as desired: Monitor Mount (Optional) Backscatter Shield Figure 10 Backscatter shield installed, available handle adjustments Page 15 of 29 QSA Global Inc. 40 North Avenue Burlington, MA 01803 888.272.2242 781.272.2000 F: 781.359.9179 qsa-global.com ...
  • Page 16 Figure 11 Indicators and Power Switch Details  Verify kV/mA settings on main status screen.  Perform test shot to verify X-ray functionality. Page 16 of 29 QSA Global, Inc.  40 North Avenue Burlington, MA 01803  888.272.2242 ...
  • Page 17: Accessories

     114g    The display position can be moved in multiple directions based on user preferences: Figure 12 Available directional adjustments to display Page 17 of 29 QSA Global Inc.  40 North Avenue Burlington, MA 01803  888.272.2242 ...
  • Page 18 The standard configuration provides the image to your right eye. Clear or tinted lenses can be used based on external lighting conditions: Figure 14 Example image output for HUD Page 18 of 29 QSA Global, Inc.  40 North Avenue Burlington, MA 01803 ...
  • Page 19 It is not powered by the OVDX system. Expected battery life is 10 hours. 4:3 aspect ratio is recommended Figure 15 HUD controller and power supply Page 19 of 29 QSA Global Inc.  40 North Avenue Burlington, MA 01803  888.272.2242 ...
  • Page 20: Handle Extension Assembly

    Figure 16 Handle extension assembly (Item # 415510, split rail slider not shown) Figure 17 OVDX with handle extension assembly installed on top of C-Arm. Page 20 of 29 QSA Global, Inc.  40 North Avenue Burlington, MA 01803 ...
  • Page 21: Installation Of Handle Extension Assembly

    Figure 18 Trigger assembly  Mount the remote trigger assembly harness block to the main housing assembly’s upper trigger mount: Figure 19 Trigger harness block Page 21 of 29 QSA Global Inc.  40 North Avenue Burlington, MA 01803  888.272.2242 ...
  • Page 22 Attach the trigger assembly to the extension mounting block using three allen head screws from before: Allen Head Screws Figure 21 Trigger Attached Mounting Block Page 22 of 29 QSA Global, Inc.  40 North Avenue Burlington, MA 01803 ...
  • Page 23: Monitor

    (Figure 22, Item #2), and GREEN when monitor is on. NOTICE The monitor’s DVR functionality is not compatible with the DX system. Image/video recording is handled directly within the DX system software. Page 23 of 29 QSA Global Inc.  40 North Avenue Burlington, MA 01803  888.272.2242 ...
  • Page 24 External Battery HDMI Strain Relief Power Input Jack Power Switch Figure 23 Monitor - Rear View Figure 24 Monitor’s External Battery Charger Page 24 of 29 QSA Global, Inc.  40 North Avenue Burlington, MA 01803  888.272.2242  781.272.2000 ...
  • Page 25: Imager Shield

    DX system is fully extended. Figure 3 shows the worst-case effect of output radiation levels with and without the imager shield. Page 25 of 29 QSA Global Inc.  40 North Avenue Burlington, MA 01803 ...
  • Page 26: Maintenance

    Use a soft, damp cloth to clean to remove dirt and grime from the OVDX. CAUTION Do not use solvents or apply cleaning agents directly on the OVDX as this can damage the components and/or corrode the electronics. Page 26 of 29 QSA Global, Inc.  40 North Avenue Burlington, MA 01803  888.272.2242 ...
  • Page 27: Troubleshooting

    Opening the OVDX can damage the system and will void any warranty. If faced with any issues regarding the OVDX, contact your QSA Global, Inc. representative immediately for guidance. The OVDX has been designed as a rugged, safe, reliable system. A series of interlocks and self-checks are built into the system to ensure safe operation.
  • Page 28: Qsa Global, Inc. Contact Information

    Telephone +1 713 944 3200 Fax +1 281 476 9309 All goods and services are sold subject to the terms and conditions of QSA Global, Inc. A copy of these terms and conditions is available upon request. OpenVision™ is a trademark of QSA Global, Inc.
  • Page 29: Appendix 1: Parts List

    415510 Handle Extension Assembly 415230 Imager Shield Assembly OpenVision™ is a registered trademark of QSA Global, Inc. Milwaukee ® and M18™ are registered trademarks or ® trademarks of Milwaukee Tool. All product and company names are trademarks™ or registered trademarks of their respective holders.