TROU BLESHOOTING
Troubleshooting & Maintenance
Problem
Batteries inserted in wrong direction.
Device will not 
The adapter is not plug well into device 
turn on.
properly. 
Power turns 
Gel pads not attached correctly to the skin.
off too soon
Power turns off 
 if you are using the batteries operation, then 
while using 
the batteries weak/exhausted.
massager
Treatment period of 30 minutes is over and 
power turns off automatically.
 if you are using the body massage, the 
electrode gel pad may be broken
It is difficult to 
 Transparent film not peeled off
attach Gel pad 
Gel pad applied immediately after washing
to the skin
Adhesive surface of Gel pad damaged. 
The gel pads get dirty and lost their 
adhesive/stickiness.
Adhesive 
Use of Gel pad during perspiring
surface of Gel 
pad is not 
Gel pad washed too long and/or too frequently
sticky
 Gel pads stored under high temperature, high 
humidity, direct sunshine
You sole is too dry, not moisture enough
It is difficult to 
Your sole is not placing on the foot pedal 
feel stimulation
properly 
Gel pads not attached correctly to the skin
Gel pads overlap each other
Electrode cord not connected correctly
Applied intensity too weak
The skin turns 
Adhesive surface of Gel pads dirty or dry
red or the skin 
feels irritated
Adhesive surface of Gel pads damaged
Hygiene
After using the product
Clean the device with a soft, damp cloth but make sure squeeze a cloth dry and to clean the foot pedal area. Store the 
Electrode Gel pads on the plastic pad protectors provided.  
Storage 
Keep the whole set of product clean and storage in a dust free and dry location under the condition 
Storage temperature and humidity
Operating temperature and humidity
8
For more information about BioEngergiser Products visit our website at: www.globalproductcom
Cause
Insert batteries in correct direction or check the 
battery is in full power. 
check the connection of the adapter jack is in 
well connected.  And also the DC adapter with 
well connecting to the main socket. 
Attach Gel pads correctly to the skin.
Fit 4 new identical 1.5V alkaline batteries type AA.
Restart treatment or turn off the massager.
Replace electrode gel pad
Peel off film on the adhesive surface of Gel pad
Sufficiently dry Gel pad
Replace Gel pad
Replace Gel pad or clean the gel pad with a small 
drop of water onto the sticky side of the 
electrode pad and rub into the surface
Leave Gel pad in freezer for overnight
put some water to your sole to moisture your 
sole.
Ensure both of your sole are placed on each 
pedal properly. each 
Attach Gel pad firmly to the skin
Reattach Long Life pads with no overlap
Connect electrode cord correctly
Increase the intensity by turning the dial switch
Wash adhesive surface of Gel pads softly with your 
fingertips for about 3 seconds under slow running 
water
Replace Gel pads
-10°C to 60°C, 10% to 95% RH
-5°C to 50°C, 30% to 90% RH
10
Rectification