Aquion RainSoft EC4 OXYTECH Series Owner's Manual

Chemical-free iron, sulfur and manganese reduction water treatment filter

Advertisement

E E C C 4 4 O O X X Y Y T T E E C C H H
C C h h e e m m i i c c a a l l - - f f r r e e e e i i r r o o n n , , s s u u l l f f u u r r
a a n n d d m m a a n n g g a a n n e e s s e e r r e e d d u u c c t t i i o o n n
W W A A T T E E R R T T R R E E A A T T M M E E N N T T F F I I L L T T E E R R
Part No.: 16365
Rev: I
03/14

Advertisement

Table of Contents
loading

Summary of Contents for Aquion RainSoft EC4 OXYTECH Series

  • Page 1 E E C C 4 4 O O X X Y Y T T E E C C H H C C h h e e m m i i c c a a l l - - f f r r e e e e i i r r o o n n , , s s u u l l f f u u r r a a n n d d m m a a n n g g a a n n e e s s e e r r e e d d u u c c t t i i o o n n W W A A T T E E R R T T R R E E A A T T M M E E N N T T F F I I L L T T E E R R ™...
  • Page 2: Table Of Contents

    Table of Contents Application Limitations ..................3 Operational Specifications ................3 _ 4 System Alarms ......................4 Maintenance Requirements ................4 Product Certification Information..............4 Installation Instructions ................5 _ 11 System Start Up....................12 Understanding the Customer Settings ............13 Programming the Customer Settings ..........
  • Page 3: Application Limitations

    Congratulations on your purchase of a RainSoft water treatment system! This Owner’s Manual is designed to assist with the operation, main- tenance, and installation of your water treatment system. It is our sincere hope that this manual is clear, concise, and helpful to you as a new owner.
  • Page 4: System Alarms

    Existing Plumbing Conditions: Plumbing should be free from lime and/or iron buildup. Piping that contains large amounts of lime and/or iron should be replaced. Additional Specifications • Do not install this system where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
  • Page 5: Installation Instructions

    Installation Instructions 1. Safety Precautions For Massachusetts Residents only: The Commonwealth of Massachusetts Plumbing • To prevent accidents/injuries, do not hoist the system over Code 248 CMR shall be adhered to. A licensed plumber shall be used for this installation. your shoulder;...
  • Page 6 Installation Instructions continued from page 5 5. Fill the Filter Tank with Media • Remove the cap plugs from both tanks. • Pull up on the riser pipes and inspect the distributors. The filter tank will have a screen distributor ( ) and the aeration see Figure 2 tank will have an open distributor (...
  • Page 7 6. Install the Control Valves • Lubricate the riser pipe O-rings and tank O-rings with Dow 111 silicone-based lubricant or equivalent. • Align the filter control valve with the screen distributor riser Important Note: Do not over-tighten the control valves to the tanks. pipe ( ).
  • Page 8 Installation Instructions continued from page 7 9. Install the Check Valve • Install the supplied 1 check valve on the raw water supply feeding the aeration tank ( ). The check valve see Figures 5.1 & 5.2 must be installed in vertical, upflow position with a minimum 12 water column above the check valve ( see Figures 5.1 &...
  • Page 9 Installation Instructions continued from page 9 10. Connect the Plumbing • Connect the check valve outlet to the aeration tank inlet ( Important Note: All RainSoft systems require a yoke to connect the plumbing to Figure 6 the bypass valve. Helpful Tips: Do not sweat pipes with water •...
  • Page 10 Installation Instructions continued from page 9 12. Install the Drain Lines, Air Check Valve Assembly, and Air Gap 1 /2 Helpful Tips: The aeration drain line can • Connect I.D. drain line to the drain outlet of both valves; tee into the drain line of the filter or to an outlet side ( ).
  • Page 11 13. Create the Electrical Connections • Attach the U-shaped connectors to the 18/2 gauge wire with Important Notes: 18/2 gauge wire (part number 18566) must be used; do not use a crimping tool ( ). If the 18/2 gauge wire is too see Figure 11 bell wire.
  • Page 12: System Startup

    System Startup • Close all faucets and turn the water back on at the water meter or pressure tank. • Check for leaks. If a leak is present, drain the plumbing again before soldering. • Open a cold water faucet and allow the water to run for a few minutes or until all foreign material from the installation is washed out;...
  • Page 13: Understanding The Customer Settings

    Understanding the Customer Settings Menu Forward and Menu Back keys: Use to scroll through the list of functions or to change the menu choice. Info Center key: Use to access the Information Center. Manual Regeneration key: Use to initiate a manual regeneration. Enter key: Use to select or enter the menu of choice.
  • Page 14: Programming The Customer Settings

    Programming the Customer Settings Menu Forward and Menu Back keys: Use to scroll through the list of functions or to change the menu choice. Info Center key: Use to access the Information Center. Manual Regeneration key: Use to initiate a manual regeneration. Enter key: Use to select or enter the menu of choice.
  • Page 15: System Alarms

    • Press the Menu Forward key to advance to CURRENT DAY; the computer will display: CURRENT DAY • Use the Adjust Up and Adjust Down keys to select the current day. • Press the Menu Forward key to advance to CURRENT DATE; the computer will display: CURRENT DATE •...
  • Page 16: Understanding A Manual Regeneration

    Understanding a Manual Regeneration Menu Forward and Menu Back keys: Use to scroll through the list of functions or to change the menu choice. Info Center key: Use to access the Information Center. Manual Regeneration key: Use to initiate a manual regeneration. Enter key: Use to select or enter the menu of choice.
  • Page 17: Understanding The Information Center

    Understanding the Information Center Menu Forward and Menu Back keys: Use to scroll through the list of functions or to change the menu choice. Info Center key: Use to access the Information Center. Manual Regeneration key: Use to initiate a manual regeneration. Enter key: Use to select or enter the menu of choice.
  • Page 18 Filter Valve Exploded View 13 A,B...
  • Page 19 Aeration Valve Exploded View...
  • Page 20 Filter Control Exploded View...
  • Page 21 Aeration Control Exploded View...
  • Page 22 Filter and Aeration Valve Parts List ITEM QUANTITY PART NUMBER DESCRIPTION 17863 COMPOSITE VALVE BODY FOR 1 RISER PIPE 17864 END SPACER 17865 SPACER 19860 OXYTECH SEAL 19861 OXYTECH PISTON 17869 END PLUG ASSEMBLY 17870 10-24 X .812 SCREW HEX WASHER HEAD 17871 PISTON ROD 18445...
  • Page 23 Filter and Aeration Control Parts List ITEM QUANTITY PART NUMBER DESCRIPTION 17487 REAR HOUSING 19743 BRINE GEAR/CAM, AIR 17492 BRINE GEAR BRACKET 17537 VALVE MOTOR WITH COMPUTER CAM, 24V-50/60HZ 17548 10-32 X 1-1/2 SCR.PAN. H. PHIL. MACH.SS. 19536 SEALED SWITCH C-NC MALE CONNECTOR RED 19537 SEALED SWITCH C-NO FEMALE CONN BROWN 18135...
  • Page 24: Troubleshooting Guide

    Troubleshooting Guide SYMPTOM CAUSE SOLUTION 1. Systems fail to regenerate 1. The power supply is plugged into intermittent or 1. Connect to a constant power source. automatically. dead power source. 2. Systems regenerate at the 1. The computer is not set properly. 1.
  • Page 25 Independent RainSoft Dealers may include, together with your RainSoft product, a product or component that is not manufactured by RainSoft or their parent company, Aquion, Inc. Any non-RainSoft product may be covered by the manufacturer of that product, and is not covered by the RainSoft warranty. Aquion, Inc. does not warrant that your RainSoft product and the non-RainSoft product will perform properly when used together, and assumes no liability therefore.
  • Page 26 N O T E S N O T E S...
  • Page 27 N O T E S...
  • Page 28 ™ RainSoft Division of Aquion, Inc. 2080 East Lunt Avenue Elk Grove Village, Illinois 60007 Main Switchboard: 1.847.437.9400 Customer Service: 1.800.860.7638 www.rainsoft.com ©2011 RAINSOFT DIVISION OF AQUION, INC.

This manual is also suitable for:

Rainsoft ec4 oxytech 150 mmRainsoft ec4 oxytech 150 plus mmRainsoft ec4 oxytech 250 mm

Table of Contents