WARNING & SAFETY INSTRUCTIONS Before you begin the installation of the water filter, we advise you read and carefully follow the instructions contained in this manual. It contains important information about safety, installation, use and maintenance of the product. The actual system that you have received, may differ from the pictures/illustrations/descriptions in this Technical Manual.
INSTALLATION INLET & OUTLET DRAIN Check the water pressure at the place of installation We recommend the use of a stand pipe with air trap. of the water filter; it should never exceed 8,3 bar. To prevent backflow from the sewerage system into ...
START-UP PRESSURIZING 1. Make sure the bypass system is in 'bypass' position. 2. Make sure the electronic controller of the water filter is in service mode. 3. Open the mains water supply. 4. Open a cold treated water faucet nearby the water filter and let the water run for a few minutes until all air is purged and all foreign material that may have resulted from the installation is washed out;...
ELECTRONIC CONTROL PANEL Picture 6 REGENERATION MODE In regeneration mode the display shows the remaining symbol button function regeneration time and the remaining cycle time: to advance to the next SCROLL parameter Rgn:XXX CycY:ZZZ to increase the value of the parameter The control valve can be reset to service mode at any time to decrease the value of the...
Page 8
ELECTRONIC CONTROL PANEL PROGRAMMING INSTRUCTIONS Before entering the programming mode, make sure that the control valve is in the service mode. 1. Press the scroll button; the display will show: Language:English Press the up or down button to set the language.
MAINTENANCE ROUTINE CHECKS SANITIZING THE WATER FILTER If the power supply to the water filter is disconnected for a Regularly the user should perform a basic check to verify if longer period of time, we recommend, when the power the water filter is functioning correctly, on the basis of the supply is re-established, to manually initiate a complete following control points: regeneration.
TROUBLESHOOTING PROBLEM CAUSE SOLUTION Untreated water to Open or defective bypass Close or replace bypass service Water filter in regeneration Wait until regeneration finishes or manually advance regeneration to end Excessive water usage Initiate regeneration manually Change in raw water composition Verify composition of incoming untreated water and adjust regeneration frequency accordingly...