Summary of Contents for Aquion Oxydizer

  • Page 1 Fe, Mn, H WATER FILTER © 2012 Aquion, Inc. TM-EN-Oxydizer-Rev2012.08...
  • Page 2: Table Of Contents

    TABLE OF CONTENT & INSTALLATION RECORD Table of content ........................Page 2 Warning & Safety instructions ..................... Page 3 Operating conditions & Requirements ................Page 4 Installation ........................... Page 5 Start-up ..........................Page 6 Electronic control panel ....................... Page 7 Maintenance ........................
  • Page 3: Warning & Safety Instructions

    WARNING & SAFETY INSTRUCTIONS Before you begin the installation of the water filter, we advise you  read and carefully follow the instructions contained in this manual. It contains important information about safety, installation, use and maintenance of the product. The actual system that you have received, may differ from the pictures/illustrations/descriptions in this Technical Manual.
  • Page 4: Operating Conditions & Requirements

    OPERATING CONDITIONS & REQUIREMENTS APPLICATION LIMITATIONS:   Dissolved Oxygen (D.O.): xydizer: min. 15% of Iron + Manganese content xydizer : N/A  pH: for Iron removal: 6,8 - 9,0 for Manganese removal: 8,0 - 9,0 for Iron & Manganese removal: 8,0 - 8,5 ...
  • Page 5: Installation

    INSTALLATION INLET & OUTLET DRAIN   Check the water pressure at the place of installation We recommend the use of a stand pipe with air trap. of the water filter; it should never exceed 8,3 bar.  To prevent backflow from the sewerage system into ...
  • Page 6: Start-Up

    START-UP PRESSURIZING 1. Make sure the bypass system is in 'bypass' position. 2. Make sure the electronic controller of the water filter is in service mode. 3. Open the mains water supply. 4. Open a cold treated water faucet nearby the water filter and let the water run for a few minutes until all air is purged and all foreign material that may have resulted from the installation is washed out;...
  • Page 7: Electronic Control Panel

    ELECTRONIC CONTROL PANEL Picture 6 REGENERATION MODE In regeneration mode the display shows the remaining symbol button function regeneration time and the remaining cycle time: to advance to the next SCROLL parameter Rgn:XXX CycY:ZZZ to increase the value of the parameter The control valve can be reset to service mode at any time to decrease the value of the...
  • Page 8 ELECTRONIC CONTROL PANEL PROGRAMMING INSTRUCTIONS Before entering the programming mode, make sure that the control valve is in the service mode. 1. Press the scroll button; the display will show: Language:English  Press the up or down button to set the language.
  • Page 9: Maintenance

    MAINTENANCE ROUTINE CHECKS SANITIZING THE WATER FILTER If the power supply to the water filter is disconnected for a Regularly the user should perform a basic check to verify if longer period of time, we recommend, when the power the water filter is functioning correctly, on the basis of the supply is re-established, to manually initiate a complete following control points: regeneration.
  • Page 10: Hydraulic Flow Diagrams - O 2 Xydizer

    HYDRAULIC FLOW DIAGRAMS - O xydizer SERVICE BACKWASH PURGE Page 10...
  • Page 11: Hydraulic Flow Diagrams - O 2 Xydizer Pro

    HYDRAULIC FLOW DIAGRAMS - O xydizer SERVICE BACKWASH AIR INTAKE PURGE Page 11...
  • Page 12: Troubleshooting

    TROUBLESHOOTING PROBLEM CAUSE SOLUTION Untreated water to Open or defective bypass Close or replace bypass service Water filter in regeneration Wait until regeneration finishes or manually advance regeneration to end Excessive water usage Initiate regeneration manually Change in raw water composition Verify composition of incoming untreated water and adjust regeneration frequency accordingly...
  • Page 13: Electrical Wiring Diagrams

    ELECTRICAL WIRING DIAGRAMS   = position switches   = power lead   = drive motor   = key pad Page 13...
  • Page 14: Default Parameter Settings

    DEFAULT PARAMETER SETTINGS Model xydizer xydizer Filter medium, quantity (Cuft - Ltr) 1 - 28 2 - 56 1 - 28 2 - 56 Interval (days) Cycle 1: BACKWASH (min) Cycle 2: AIR INTAKE (min) Cycle 3: PURGE (min) Regen @ 0:00 0:00 0:00...
  • Page 15 Page 15...
  • Page 16: Exploded View - System

    EXPLODED VIEW - SYSTEM Page 16...
  • Page 17 EXPLODED VIEW - SYSTEM Item Description Remark  PT/1040/BA Pressure tank 10x40 1 Cuft  PT/1252/BA Pressure tank 12x52 2 Cuft A8006 Birm multiple of 1 Cuft (28 Ltr)  38534 Riser tube assembly to be cut to length  28/298/11 Transformer 230/24V - 50 Hz, 24VA, EuroT plug ...
  • Page 18: Exploded View - Timer Head

    EXPLODED VIEW - TIMER HEAD Page 18...
  • Page 19 EXPLODED VIEW - TIMER HEAD Item Description Remark  70971 Power lead with plug 72263 Clamp 28/244/1 Plug (large) 71502 Screw, timer cover (3x) 15/222 Screw, back plate (2x) 70962 Back plate 2100/206 Drive shaft 15/222 Screw, drive motor assy (2x) 28/245/4 Cable clamp 71502...
  • Page 20: Exploded View - Valve Body O 2 Xydizer

    EXPLODED VIEW - VALVE BODY - O xydizer Page 20...
  • Page 21 EXPLODED VIEW - VALVE BODY - O xydizer Item Description Remark 21/83 Drain connection 568/271/N Backwash flow control N (22,7 Ltr/min) 1 Cuft 568/271/Q Backwash flow control Q (30,3 Ltr/min) 2 Cuft 72678 Bolt, valve cover (6x) 568/254/3 Valve cover 185/154/1 O-ring, valve cover 186/112...
  • Page 22: Exploded View - Valve Body O 2 Xydizer Pro

    EXPLODED VIEW - VALVE BODY - O xydizer Page 22...
  • Page 23 EXPLODED VIEW - VALVE BODY - O xydizer Item Description Remark 21/83 Drain connection 568/271/N Backwash flow control N (22,7 Ltr/min) 1 Cuft 568/271/Q Backwash flow control Q (30,3 Ltr/min) 2 Cuft 72678 Bolt, valve cover (6x) 568/254/3 Valve cover 185/154/1 O-ring, valve cover 186/112...
  • Page 24: Technical Specifications

    TECHNICAL SPECIFICATIONS Technical specifications: Model xydizer xydizer Filter medium, quantity (Cuft - Ltr) 1 - 28 2 - 56 1 - 28 2 - 56 Operating pressure min/max (bar) 2,0/8,3 Operating temperature min/max (°C) 2/48 Electrical connection (V/Hz) 230/50 Max. power consumption (VA) Hydraulic connection inlet/outlet 3/4”...
  • Page 25 Page 25...