Control Logic; Connector; Mode Setting; Fan Speed Setting - Bosch Climate 5000 Series Installation Manual

24 volt interface, for use with bosch split-type ductless air conditioner/heat pump, 208/230v 60hz 1ph, 115v 60hz 1ph
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

1 0 | Bosch Climate 5000 Series 24 Volt Interface

6 Control Logic

6.1 Connector

Connector
Y
W
G
AUX/DRY
Table 6

6.2 Mode Setting

Y
W
G
Aux/Dry
*
*
X
*
X
X
*
X
X
X
X
*
*
X
X
X
X
*
X
X
Table 7
√   = ON
X       = OFF
*
= ON or OFF

6.3 Fan Speed Setting

Unit ON/OFF
G
X
X
X
Table 8
√   = ON
X       = OFF
Data subject to change
Purpose
Cooling
Heating
Fan- Auto speed
Aux-Heat/Dry
Setting mode
Cooling
Heating (without aux-heater)
Heating (with aux-heater)
Fan only
OFF
OFF
Dry
Setting fan speed
Auto fan speed
Auto fan speed
Fan OFF
7 Dip Switch Confi guration
The 24V INTERFACE must be confi gured to operate properly with the system
components with which it is installed. To successfully confi gure the system, move
the Dip Switches to match the components and functions used.
7.1 Dip Switch Defi nitions
SW1
SW2
Figure 8
Dip Switch 1-1
Used to turn ON or OFF the diagnostic code display LED on the control board of the
24V Interface.
SW1-1
Result
ON
Display on
OFF
Display off
Table 9
Dip Switch 1-2
Used for selection of the indoor unit type.
SW1-2
Result
ON
Enables 24V INTERFACE to work with IDU & ODU
OFF
Table 10
Must be switched to ON before using the system.
Dip Switch 2-1
Used for selection of the system: Cooling Only or Heat Pump.
SW2-1
Result
ON
Cooling only
OFF
Heat pump
Table 11
Installation Manual
SW3
SW4
Note
Default
Note
N/A
Default
Note
Default
06.2019 | Bosch Thermotechnology Corp.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents