à Fastening the pump
If the pump is producing some abnormal noise, slightly unscrew without creating leakage, then screw
again following instructions below.
1 - Tighten the two opposite screws to a torque
of 3 Nm.
3 - Tighten the first two opposite screws to a
torque of 5 Nm.
Side casing
Front casing
Control pannel
Pump
Klixon 60°C
Klixon 100°C
3 bar relief valve
8L expansion vessel
Water sensor
6 kW heating element
Heating element gasket
20A tetrapole switch
Fuse holder
4A fuse size 5x20
Control PCB, electronic card
Water temperature sensor
Drain Valve
Drain Tube
SPARE PARTS LIST
Designation
POWERSTREAM Ascari -p. 38 -
2 - Tighten the other two opposite screws to a
torque of 3 Nm
4 - Tighten the last two opposite screws to a
torque of 5 Nm.
Reference
PSA 12
EB06001
EB06002
EB06003
EB06004
EB06005
EB06006
EB06007
EB06008
EB06009
EB06010
EB06011
EB06012
EB06013
EB06014
EB06016
EB06017
EB06018
EB06019
1
1
1
1
1
1
1
1
1
2
3
4
1
1
1
1
1
1