CHECK FOR LEAKS
Turn on shut-off valve and check for leaks. If connections
are squarely assembled, a slight re-tightening of the nuts
will stop any leaks. Check all connections for leaks for
several days. The nuts under the bolt caps may also re-
quire re-tightening.
TO ADJUST WATER LEVEL
To obtain the correct water level in the tank, adjust the
Tank Water Level Screw, by turning counterclockwise to
raise the water level, or clockwise to lower the water level.
AA
112363–2–
(0793)
Lower
Fig. #11
6
Fig. #10
Tank Water
Level Screw
Raise