Touch once (Function #1):
Reset all options to factory default, then test hardware in the following order:
1/ LEDs. 2/ Alarm Buzzer. 3/ Solar charger. 4/ Reboot automatically after 20 seconds.
Touch twice (Function #2):
Timer is switched OFF. Energiser will operate
setting).
Touch 3 times:
Timer is switched onto
after sunset). During the day the Energiser is OFF and the FENCE LED glows BLUE.
(For increased battery life).
Touch 4 times:
Timer is switched onto
minutes after sunrise). At night the Energiser is OFF and the FENCE LED glows
(For increased battery life).
Touch 5 times:
Internal alarm buzzer is switched OFF.
Touch 6 times:
Internal alarm buzzer will only sound during daylight hours. (Factory default setting).
Touch 7 times:
Internal alarm buzzer is switched ON and can sound at any time of day or night.
Touch 8 times:
Report the current fence voltage in kilo-volts (0.5 to 9.9kV). Useful for fence
diagnostics.
Method: 1. Count the number of flashes of POWER LED; this is the first digit.
2. Count the number of flashes of the FENCE LED; this is the second digit.
NOTE: When the Energiser is first switched on the Fence LED flashes rapidly BLUE
while it is processing; this means please wait (typically 10 seconds). Then select this
Function. Normal range is 2kV to over 8kV.
Touch 9 times:
Reports the lowest fence voltage since mid-night.
Touch 10 times:
Reports the highest fence voltage since mid-night.
More than 10:
Does nothing. Beeps an error.
Night Mode
& will only operate at night (from 30 minutes
Day Mode
& will only operate during the day (from 30
24 hours a
day. (Factory default
BLUE.
8