Fan Voltage Per Control Mode; Exerted Fan Motor Voltage; Load Mode; Operating Condition - Daewoo FPS-X22D1 Series Service Manual

Mineral water refrigerator
Table of Contents

Advertisement

3. Fan voltage per control mode

Exerted fan motor voltage

Mode
Normal mode
Super Freezer mode

Load mode /

4 hours after defrosting
/
RT >= 38C
1) Normal control : Slow operation mode with relatively low noise level.
2) Load mode : Operation mode which need to be operated by temperature rise at inner side of
refrigerator according to operating condition.
4. Load mode
1) Purpose : To recover temperature rise inside of refrigerator as quickly as possible by load or frequent door opening.

2) Operating condition

- When door opening time is more than 1 minutes per 1 time -> Frz. / Ref. go to load mode.
- When sensing more than R/S On Point + 5deg : Ref. load response.
- When sensing more than F/S On Point + 5deg : Frz. load response.
3) Conditions for inactive load response mode.
- When there is no door opening signal during and after defrost cycle, load response mode is inactive.
4) Terminate condition
- After 20 mintues.
- When Ref. sensor reaches to off point, Ref. load mode ends.
- When Frz. sensor reaches to off point, Frz. load mode ends.
F-Fan
10 V
13 V
13 V
C-Fan
13 V
13 V
13 V