3.2.2

Station address setting

Set a station address using the station address setting switches. Any station address
may be set, provided that it is unique in the system.
The range of station address setting is from 01h to FEh (1 to 254). If the IP address type
[Tool Setting] is set, however, the network ID has priority over the value set with the
station address setting switches. In Tool Setting, set a station address in decimals.
3.2.3

Setting with the Engineering Tool

Hub registration
The hub registration procedures are as follows:
Select a system for registering the hub using [Product View], and execute [File] and
[New].
Select the model type V-series (other stations), and enter a folder name.
Start [Configuration Edito] for the registered hub station, and change the main unit.