Garrett MAGNASCANNER CS 5000 Owner's Manual

Garrett MAGNASCANNER CS 5000 Owner's Manual

Hide thumbs Also See for MAGNASCANNER CS 5000:

Advertisement

OWNER S MANUAL
MAGNASCANNER CS 5000 with DSP
MODEL 11674XX
Garrett Metal Detectors, Inc.
1881 W. State Street
Garland, TX 75042-6797 USA
Tel: 972-494-6151
Fax: 972-494-1881
APPROVED
E-mail: security@garrett.com

Advertisement

Table of Contents
loading

Summary of Contents for Garrett MAGNASCANNER CS 5000

  • Page 1 OWNER S MANUAL MAGNASCANNER CS 5000 with DSP MODEL 11674XX Garrett Metal Detectors, Inc. 1881 W. State Street Garland, TX 75042-6797 USA Tel: 972-494-6151 Fax: 972-494-1881 APPROVED E-mail: security@garrett.com...
  • Page 2 Security type metal detectors are important tools, designed for use within a total security screening system. It is the responsibility of the end user to define the system and to ensure proper operation of all aspects of the system. ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00...
  • Page 3 Perform verifications test using problems/deficiencies to the sales representative selected objects. (See Supervisor and manufacturer as well. Responsibilities, Page 16.) Magnascanner, Super Scanner and Enforcer G-2 are “ of Garrett Electronics, Inc. If further assistance is required, call the factory at 1-800-234-6151.
  • Page 4: Table Of Contents

    11.8. ELECTRICAL WIRING ........44 ' 2000 GARRETT METAL DETECTORS, INC.
  • Page 5: General Description

    The Magnascanner CS 5000 offers a diverse range of programs to meet your security needs. The detector is highly portable and can be operated by remote console or a battery pack as needed.
  • Page 6: Controls & Modules

    Operators should be instructed to respond to all alarms. For any detector to be effective in a security system it is absolutely necessary that the cause of EVERY ALARM be determined. ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00...
  • Page 7: Touchpads

    2.2.2. OPERATE Whenever this touchpad is pressed, the Magnascanner CS 5000 activates all circuits, initiates a self-diagnosis program and places the unit in the Operate Mode within fifteen (15) seconds. This diagnostic program for instant fault detection can be activated at any time by touching this OPERATE pad.
  • Page 8 If an operator should inadvertently press the ACCESS touchpad, no further action should be taken and the unit will return automatically to the Operate Mode in about ten (10) seconds. ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00 Revised...
  • Page 9: Internal Modules

    This module, which includes two (2) 12v batteries and charging circuitry that comprise the optional battery pack, will be stored behind this cover and connected with the Controller Module. This pack has a switch which is used to disconnect battery power. ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00...
  • Page 10: Installation Instructions

    3.1. SITE SELECTION The Garrett Magnascanner CS 5000 should be located on a level, stable floor with no large metal items within three (3) feet. Any nearby large metallic object can interfere with operation of the detector. Moving metallic objects, such as an escalator or revolv- ing door, close to the detector can cause false alarms.
  • Page 11: Assembly

    MAGNASCANNER CS 5000 OWNER S MANUAL 3.2. ASSEMBLY 1. Lay out the major pieces of the Magnascanner CS 5000, as shown at the right. Make certain all other attach- ment devices are included. These should include: Detection Panel A l Detection Panel B...
  • Page 12 Detection Unit and Overhead Crosspiece to the Side Panels and adjust as necessary. 9. Connect to the power line, and proceed with Installation Adjustments (See Page 12.) ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00 Revised...
  • Page 13: Self-Diagnostic Tests

    MAGNASCANNER CS 5000 OWNER S MANUAL SELF-DIAGNOSTIC TESTS The Garrett Magnascanner CS 5000 LCD panel provides valuable information concern- ing the operation of this unit and the self-diagnostic program of which it is capable. 4.1. OPERATING INFORMATION When the unit is placed into operation from the Standby Mode, the following informa- tion is reported: 1.
  • Page 14 READY light appears. ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00...
  • Page 15: Installation Adjustments

    The Installation Adjustment Mode, which can be accessed only through use of a four- digit code (Access Code #2), permits the Magnascanner CS 5000 to be set up properly for best performance in a given operational environment. Various options permit setting the unit for proper operation in conjunction with other walk-through units or for dealing with typical operation problems.
  • Page 16 5. Press OPERATE to exit the Adjustment Mode and enable the detector to be operat- ed normally. If ACCESS is pressed, this Installation Adjustment cycle will be repeat- ed, beginning with Receiver Balance. ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00...
  • Page 17: Supervisor Adjustments

    6.1. PROGRAM The programs detailed on Pages 35-37 have been developed for use by the Garrett Magnascanner CS 5000. These brief descriptions will give some indication of the intent of each program, but a final judgment on the setting of each individual unit should be determined by the intent of its installation.
  • Page 18 OPERATE to return to normal operation. 6.3. IR ANALYSIS The Garrett Magnascanner CS 5000 utilizes an Infrared Sensor to enhance the opera- tion of the unit in special situations. IR Analysis ON or OFF appears on the LCD to indicate whether or not the IR Analysis is being used.
  • Page 19: Supervisor Responsibilities

    7.2. FAA TEST PIECE Garrett manufactures an OTP made to the specifications of the U. S. Federal Aviation Administration (Garrett Accessory #1600600). It is important to understand that OTPs come in various sizes, shapes and composi- tions, depending upon the calibration requirements of individual screening installations.
  • Page 20: Technical Specifications

    DC switch can sink 100mA from a 15V source. Connections to 15V and system ground are provided for use with internal or external power source. ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00...
  • Page 21 Justice (NILECJ) standard 0601.00, security levels 1-5. 8.11. REGULATORY INFORMATION The Garrett Magnascanner CS 5000 meets or exceeds detection requirements of the National Institute of Law Enforcement and Criminal Justice Standards #0601.00, levels 1-5, and Federal Aviation Administration airport application specifications. Programs have been designed specifically to meet the three-gun test of the FAA and the require- ments of the Undetectable Firearm Act of 1991.
  • Page 22 3.2.2 which addresses the issue of electromagnetic effects to cardiac pacemak- ers. Our research has produced no information which would indicate that the Garrett prod- ucts would have any adverse effects on medical implants, pregnancy, recording media, or magnetic strips. Any additional recommendations or directives issued by personal physicians or medical equipment manufacturers should be followed.
  • Page 23 Throughput rate: Not limited by electronics; 50-60 detections/ minute is reasonable. ¥ Optional features: Remote operating capability (indicators and/or console); bat tery back-up module (built-in for portability); Magnadolly (for easy movement of assembled unit). ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00 Revised...
  • Page 24: Maintenance & Repair Periodic Maintenance

    It is necessary to test the system carefully to verify operation and the suitability of the product after any component replacement. ' 2000 GARRETT METAL DETECTORS, INC. PN 1530100 4/30/00...
  • Page 25 MAGNASCANNER CS 5000 OWNER S MANUAL ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00 Revised...
  • Page 26 MAGNASCANNER CS 5000 OWNER S MANUAL ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00 Revised...
  • Page 27: Replacement Parts

    Ribbon Cable-16 conductor, 6 9504700 Screw 1/4-20x3 9820400 Finishing Washer 9820500 Screw 4-40x3/8 flat head, light beige 9822980 Crosspiece 9968800 Cover with window 9969590 Controller cover 9984500 Cord Set 9434900 ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00 Revised...
  • Page 28: Warranty

    Garrett s performance specifications. Garrett will repair or replace at no charge to the owner all parts determined faulty. This Warranty does not cover batteries nor any and all failures caused by abuse, tampering, theft, failure due to weather, battery acid or other contaminants and equipment repairs made by an unauthorized party.
  • Page 29 OWNER S MANUAL 10.1. BASIC INSTRUCTIONS In addition to following all operating procedures as directed by supervisors the operator of a Magnascanner CS 5000 detector has only these responsibilities: ¥ Assure that the detector is always operating properly; ¥ Select Off and Operate / On modes;...
  • Page 30 When this touchpad is pressed, the unit goes into a low power mode, ready to be returned to full operation when the OPERATE pad is touched. Operators should use all touchpads only as instructed by supervisors. ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00...
  • Page 31 10.8.2. OPERATE When this touchpad is pressed, the Magnascanner CS 5000 activates all circuits, initi- ates a self-diagnostic program and places the unit in the Operate Mode within 10 sec- onds. This diagnostic program for instant fault detection can be activated at any time by touching this OPERATE pad.
  • Page 32 ¥ These directives will govern the response of operators to alarms and other situations that will be encountered. The basic continuing responsibility of the operator will be to ensure that the Magnascanner CS 5000 operates properly at all times as indicated by its LCD panel and that ALL alarms are investigated.
  • Page 33 It is important to remember that after power has been turned on, the Magnascanner is operating at all times. Its IR Sensor capability inhibits the alarm only when there is no object or person within the archway. ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00...
  • Page 34 Because of the high level of design quality represented by the Magnascanner CS 5000 and its IR Sensor, it can be expected to produce relatively few nuisance alarms when installed properly.
  • Page 35 10.19. SUMMARY It is important that all operators study the guidelines in this section carefully and remember their basic responsibilities for operating the Magnascanner CS 5000 as stated on the first page: ¥ Make sure power is turned on; ¥ Make certain the unit is operating properly;...
  • Page 36: Additional Information

    ___________ _______ _____ _____ ________________________ ____ ___________ _______ _____ _____ ________________________ ____ ___________ _______ _____ _____ ________________________ ____ ___________ _______ _____ _____ ________________________ ____ ___________ _______ _____ _____ ________________________ ____ ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00 Revised...
  • Page 37: Programs

    Immunity to external noise is moderate, making this program usable in most envi- ronments. ¥ Discrimination is poor. ¥ Recommended applications include prisons and other installations where volume requirements allow thorough inspection of each individual. ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00 Revised...
  • Page 38 ¥ Immunity to external noise is moderate, making this program usable in most envi- ronments. ¥ Discrimination is moderate to good. ¥ Recommended applications include loss prevention. ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00 Revised...
  • Page 39: Multiple Unit Operation

    Standby to Operate. If the noise flicker increases on the BAR GRAPH of a unit, then it may be necessary to select another set-up. ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00...
  • Page 40 This jumper is located on the Controller Board Assembly. Refer to the drawing for exact location. Procedure: ¥ Disconnect units from power line; ¥ Open Access Door of Detection Unit; ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00 Revised...
  • Page 41: Ac & Dc Control

    The output is an open collector configuration capable of switch- ing 15V at 100mA or less, which includes connections to computing devices and other equipment requiring low level DC. ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00...
  • Page 42 Open Access Door of detection unit; ¥ Remove three (3) screws that hold controller cover; ¥ Connect the relay or device to control, as shown at right. ¥ Replace cover and reconnect power. ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00 Revised...
  • Page 43 A complete remote console with all control func- tions that are available on the overhead panel is available for monitoring and controlling func- tions of the Magnascanner CS 5000 from a location apart from the archway. This remote console is connected to the over-...
  • Page 44: Battery Back-Up Module

    This optional module is a field-installable assembly that provides power to operate the Magnascanner CS 5000 for up to twenty (20) hours on a fully charged battery. System software includes an alarm feature that alerts the operator to a low-battery condition.
  • Page 45: Stabilizer Base

    6. Place unit in upright position at selected operating location. 7. Secure the unit to the floor using 1/4 (6mm) mounting screws (not supplied). The mount- ing holes in the plates may be used as a drill guide. ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00...
  • Page 46 MAGNASCANNER CS 5000 OWNERS MANUAL Caution: Adjust the width of the unit at the bottom of the panels to 30 (762mm) BEFORE making the holes in the next step.) ' 2000 GARRETT METAL DETECTORS, INC. PN 11674XX 4/30/00 Revised...
  • Page 47: Electrical Wiring

    To Line Hot White To Line Neutral Magnascanner CS 5000 # 11674XX (International) Comes with a European power cord. If the plug must be replaced or removed to hardwire to an AC junction box, use the following wiring list: Green/Yellow...
  • Page 48 Copyright '2000 Garrett Electronics, Inc. PN 1530100/0400...

This manual is also suitable for:

11674

Table of Contents