  • Page 1 iCAN NetZero Plus ® User Manual V1.0.0...
  • Page 3: Table Of Contents

    Warning Label ..................3 General Information ................. 3 Environmental Conditions ................ 5 Cleaning and Maintenance ............... 5 Emergency Situations ................6 About iCAN NetZero Plus ................7 Overview ....................7 Typical Applications .................. 7 Parts and Features..................8 Specifications ..................13 Installation ....................
  • Page 4 Service ...................... 7...
  • Page 5: Preface

    This document and all information discussed herein remain the sole and exclusive property of POMCube. iCAN NetZero Plus system may be updated for technical reasons without prior notice. Purchasing this product indicates that you have acknowledged it and accepted it.
  • Page 6: Fcc Statement

    waste disposal service, or the shop where you purchased the product. FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation.
  • Page 7: Safety Instructions

    Please pay attention to the warning labels and follow the instruction mentioned. POMCube disclaims all liability for any accidents or damage caused by using the product in the ways that are not described in this User Manual or using non- genuine parts or accessories.
  • Page 8 Do not impact, pull, drag, or step on iCAN NetZero Plus. Do not subject iCAN NetZero Plus to any strong force. To help prevent damage, leave iCAN NetZero Plus in its shipping packaging until it is ready to be installed.
  • Page 9: Environmental Conditions

    CAUTION: Do not place iCAN NetZero Plus in a storage condition for more than one (1) month, or permit the electrical feed on the iCAN NetZero Plus to be severed for more than one (1) month, without placing iCAN NetZero Plus into a storage condition in accordance with POMCube’s storage...
  • Page 10: Emergency Situations

    WARNING: iCAN NetZero Plus and its components are not user serviceable. Do not dismantle the device. Do not attempt to repair the device or its accessories by yourself, as damage or personal injury may occur. Damage caused by unauthorized repair is not under the warranty.
  • Page 11: About Ican Netzero Plus

    About iCAN NetZero Plus Overview iCAN NetZero Plus is an intelligent energy storage system to power your home especially the heavy loads 24/7 in emergencies like blackouts, relieve you from heavy electricity bills, and even help you to be energy self-sufficient. You may monitor your energy generation and consumption with the mobile APP anytime and anywhere.
  • Page 12: Parts And Features

    Partial backup power (basically critical loads) and generator with solar panels for grid-tied homes. Utility Meter Main Panel iCAN NetZero Plus Sub Panel Critical Load Generator … PV Array Solar generator with solar panels for off-grid homes. Generator iCAN NetZero Plus...
  • Page 13 Wiring Box Run Indicator Network Status Indicator Indicator Power Indicator Sealed Cap...
  • Page 14 PV Switch Wi-Fi Antenna ON/Off Button 4G Main Antenna Switch AC Switch GPS Antenna 4G DIV Antenna Reset Button Wiring Box Universal PCS Parts and Features Parts & Features Notes PV Switch Connect/Disconnect the PV input AC Switch Connect/Disconnect the load output On/Off Button Power on/off the system Reset Button...
  • Page 15 unit Solid Red: Energy management unit internal communication fault Blinking Green: System is turned off by energy management unit Solid Green: System running normally Solid Green: Inverter/PV charging unit running normally Solid Red: Inverter unit fault Solid Yellow: PV charging unit fault Run Indicator Blinking Red: Inverter/PV charging unit alarming Blinking Green: Inverter unit/PV charging unit...
  • Page 16 BCMS Module Status Indicator Start Button Power Switch BCMS Module Front View Battery Module Status Indicator BCMS Module Front View Battery System Parts and Features Parts & Features Notes BCMS Module Battery management system Battery Module Wiring Box Open it to switch on/off battery system, or check Enclosure Door battery indicator lights.
  • Page 17: Specifications

    Power Switch Connect/Disconnect the battery output Start Button Manually start battery system Indicate real time battery capacity: Each light SOC Indicator represents 25% capacity. The lights blink in sequence under system charging and discharging. Blinking Yellow: Startup or upgrade in progress Battery System Blinking Blue: Self-inspecting Status Indicator /...
  • Page 18 Rated Frequency 60Hz Max. Output Current 32A, 42A, 45.8A, 52A @ 240V Adjustable Power Factor 0.8 Leading ~ 0.8 Lagging ≤ 3% Grid / Generator Input Rated Power 7.5kW, 10kW, 11kW, 12.5kW Voltage Range 216V ~ 264Vac Frequency Range 55 ~ 65Hz Load Output Rated Power 7.5kVA, 10kVA, 11kVA, 12.5kVA...
  • Page 19 Over Temperature Protection Over Current Protection DC surge Protection AC Surge Protection Leakage-Current Protection Insulation Monitoring Ground-Fault Isolation Detection General 25.6in*24.4in*9.5in Dimensions (W * H * D) (650mm*620mm*241.5mm) Weight 88lbs (40kg) Communication Interface Wi-Fi, Ethernet, 4G, RS485, CAN Display LED, iOS / Android App Topology Transformerless -13˚F ~ 140˚F (-25˚C ~ 60˚C)
  • Page 20 Rated Energy 21.3kWh Usable Energy 19.1kWh @ 5kW Nominal Voltage 409.6Vdc Nominal Capacity 52Ah Charge Voltage 448Vdc Operating Voltage Range 384 ~ 467.2Vdc Continuous Power 7.5kW 30 Minutes Power 12.5kW Peak Power 21.3kW @ 1s Protection Over/Under Temperature Over/Under Voltage Over Current Short Circuit General...
  • Page 21: Installation

    UL9540, UL1973, UL1642, UL1998, CSA Safety C22.2 NOTE: Slight weight deviates for each device. Installation Tools and Safety Gear NOTE: It is recommended to use proper tools and wear safety gears when installing. Items Specification Notes Percussion drill Drill φ 10.0 Drill holes on the wall Inner Hexagonal 4mm, for M5...
  • Page 22: Installation Conditions

    Marker φ ≤8mm Mark Installation Conditions iCAN NetZero Plus shall be installed indoor, on a side wall of a garage or energy room. Horizontal installation is required. Reserve enough space for maintenance and pay attention to the maintenance space requirement for each side.
  • Page 23: Mounting

    50cm 50cm (19.7inch) (19.7inch) Maintenance Space Mounting Attach the bracket to the back side of the battery system with M5x12 Sem screws.
  • Page 24 Install the bracket and battery system on the wall with M6x50 tapping screws. NOTE: Properly drill into a concrete wall with M6x50 expansion anchor screws. CAUTION: Dust proof is required during drilling. CAUTION : Make sure the cabinet is just on the floor. The bracket is only for keeping the battery system from dumping, while only the floor is bearing the load.
  • Page 25 Hang the inverter on the bracket. NOTE: Before installing Universal PCS, remove the battery seal cap (BAT/COM) on the bottom of Universal PCS. Fasten the inverter and the bracket with M4x16 Sem screws.
  • Page 26 If Universal PCS hybrid inverter is installed separately from battery system, use the bracket for Universal PCS: install the bracket on the wall with M6x50 tapping screws, hang Universal PCS on the bracket and fasten it with M4x16 screws. NOTE: Drill properly into a concrete wall, then screw with M6x50 tapping screws. CAUTION: Dust proof is required during drilling.
  • Page 27 406.4mm (16inch) 304.8mm (12inch) Installation requirements of battery bracket Battery system installed separately...
  • Page 28: Battery System Installation

    Battery System Installation Unlock and take off the enclosure door of the battery cabinet. Gently plug in the battery modules from the bottom up, then the BCMS module on the top. Fasten the modules on both sides M4x8 screws.
  • Page 29: Internal Wiring

    NOTE: Keep the door from the cabinet until all installations are completed and system works normally. Internal Wiring Remove the screws on the wiring box of the battery cabinet and take off the cover board:...
  • Page 30 Wire cables of power, 12Vdc and communication between battery system and Universal PCS. Internal wiring of battery system...
  • Page 31 Power cable wiring Communication and DC12V cable wiring...
  • Page 32: External Wiring

    External Wiring WARNING: All external ports should be equipped with switches. CAUTION: All cables shall be connected in sequence as listed in this manual. NOTE: The actual connection depends on your application case. Not all the ports are necessary to be connected. Refer to the table below for minimum copper wire sizing and ratings.
  • Page 33 Connect iCAN NetZero Plus to grid.
  • Page 34 Connect iCAN NetZero Plus to the generator. WARNING: Ensure that the generator power is higher than the charging power of iCAN NetZero Plus, or it may lead to generator protection. If the power of generator is inadequate, please follow the instructions on our APP to set the maximum power of generator.
  • Page 35 Connect iCAN NetZero Plus to photovoltaic. Connect iCAN NetZero Plus to external AFCI. Connect the communication cable and 12Vdc power cable. CAUTION: Communication and 12Vdc cables must be connected to the...
  • Page 36 AFCI Device. Connect iCAN NetZero Plus to a router using an Ethernet cable.
  • Page 37: Accessories Installation

    Accessories Installation Install the antennas to right points as specified below. Insert the 4G SIM card (Optional).
  • Page 38: Safety Check

    Safety Check WARNING: Check thoroughly of all operations in the installation, ensuring the system is installed correctly, esp. DC and AC voltages are in the specified ranges of iCAN NetZero Plus. Teble 5.8.1 Installation Checklist Items Notes PV connection External breaker is installed.
  • Page 39: Basic Operations

    covers Conduit All conduits are tightly installed and sealed. Wire protection Insulated cover of wires are not at risk of being cut or damaged. Basic Operations Boot System WARNING: Proceed to the following steps only after installation checklist is completed. Switch on the POWER switch on the BCMS module, press START button for 1s and release, wait around 60 seconds until the BCMS and Battery Modules start normally, and...
  • Page 40: Getting Started With The App

    Getting Started with the APP Download the APP You may search “Eloncity” in Apple App Store or Google Play, or scan the QR code below or on the packing box to download the app from Apple App Store or Google Play. Apple App Store Google Play Add New Devices...
  • Page 41: Reset Network

    connection. Reset Network Long press RESET button for 4 seconds. Re-configure the network following the instructions in the app. Troubleshooting In any cases of device failure, please check alarms on APP and proceed as instructed accordingly. If APP fails to connect to the device, check the status of indicators and possible reasons and solutions as follows: The Network Indicator on Universal PCS is always solid red.
  • Page 42 The Network Indicator on Universal PCS is always solid white. Something goes wrong with Check your internet status. Reset the router the router or Internet. if necessary. Failed to start the generator remotely. The generator may not work Check the generator. properly.
  • Page 43 blue for over 60 seconds. Battery system failed in self- Reboot the battery system. inspection. The Status Indicator on at least one battery module keeps blinking in (10) blue for over 30 seconds Failure in CAN Reconnect communication cable between communication.
  • Page 44: Warranty And Service

    Warranty and Service Limited Warranty Thank you for purchasing POMCube iCAN NetZero Plus. POMCube values your business and always attempts to provide you the very best quality of service. POMCube warrants to the purchaser of the product in its original sealed packaging that the product is free from defects in material and workmanship, for the limited warranty period, beginning on the date the product was installed.
  • Page 45: Remedies

    (new or refurbished), or refund you the market price of an equivalent product at the time of the warranty claim. If your iCAN NetZero Plus is repaired or replaced under this Limited Warranty, the remainder of the original warranty period will apply to the repaired or replacement product.
  • Page 46: Legal Rights

    NetZero Plus’s performance; (c) damage or deterioration that occurs after the expiration or voiding of the warranty period; or (d) theft of your iCAN NetZero Plus or any of its components.
  • Page 47 Service If you have any questions, please contact us at service@pomcube.com, if it becomes necessary to return the device for repair, contact your local distributor for more information.
  • Page 48 POMCube Inc. © 2020 POMCube Inc. All rights reserved. For more information, please visit www.pomcube.com Follow us on Facebook / Twitter / Instagram / Reddit: Search for keyword “POMCube”...