Download Print this page

Mounting Options - Ecco ED5050 Series Installation And Operation Instructions Manual

Directional led (single colour) warning lamps

Advertisement

Available languages

Available languages

Installation & Mounting:
Before installation, examine the LED head for transit damage, do not use damaged or broken parts. The mounting
location should allow the maximum visibility of the warning device to other road users, whilst allowing for sufficient
cable access. The units should be mounted so that the rear surface of the lamp is perpendicular to the road surface
and vehicle longitudinal centre line.
Cable functions are as follows:
Black cable:
Negative. Connect to either the battery negative or a suitable chassis point.
Red cable:
Positive. Switched 10 – 30VDC supply to operate the LED light head. Must be protected by a fuse as
close to the battery supply as possible (2A recommended).
Blue cable:
Flash pattern set. Touch cable to negative momentarily to change the flash pattern:
0 – 1 seconds:
1 – 3 seconds:
3 – 5 seconds:
Over 5 seconds:
Yellow cable:
Synchronised flash:
Alternating flash:
Page 2 of 4
P/N 920-5050-00 (Rev E) 2018-06-29
next pattern
previous pattern
factory default pattern
Last Pattern
Set all units to the same flash pattern and then connect the yellow cables
together.
Set all the units to either Phase 1 or Phase 2 of the same flash pattern and
then connect the yellow cables together. Units set to Phase 1 will alternate
with units set to Phase 2.