New Holland TC21D Operator's Manual page 89

Table of Contents

Advertisement

COOLING SYSTEM
Type . . . . . . . . . . . . . . . . . . . . . . . . . . .
Water Pump:
Type . . . . . . . . . . . . . . . . . . . . . . . . .
Drive . . . . . . . . . . . . . . . . . . . . . . . . .
Belt Deflection . . . . . . . . . . . . . . . . .
Fan Diameter . . . . . . . . . . . . . . . . . .
Thermostat:
Start to Open . . . . . . . . . . . . . . . . . .
Fully Open . . . . . . . . . . . . . . . . . . . .
Radiator Cap . . . . . . . . . . . . . . . . . . .
ELECTRICAL SYSTEM
Alternator . . . . . . . . . . . . . . . . . . . . . .
Battery . . . . . . . . . . . . . . . . . . . . . . . . .
Starting Motor . . . . . . . . . . . . . . . . . . .
FUEL SYSTEM
Fuel Type . . . . . . . . . . . . . . . . . . . . . .
Type of Fuel to Use if Above 40°F
Type of Fuel to Use if Below 40°F
Injection Pump:
Type . . . . . . . . . . . . .
Timing . . . . . . . . . . . .
SECTION 4 - SPECIFICATIONS
Model TC21D—
Hydrostatic/Gear
Pressurized Liquid with
Recirculating Bypass
Centrifugal
V-Belt
10 mm-15 mm
(7/16"-9/16") when 9-11 kg (20-25
lbs.) thumb pressure is applied mid-
way between belt pulleys
335 mm (13.19")
82°C (200°F)
95°C (228.6°F)
0.9 bar
(13 PSI)
12-volt, heavy-duty, 40 amps
12-volt, w/ negative ground, 325 cca 12-volt, w/ negative ground, 325 cca
Solenoid
Pre-Engaged Reduction
Diesel
No. 2-Diesel, Cetane Rating:
Minimum 40
No. 1-Diesel, Cetane Rating:
Minimum 40
In-Line
21° BTDC
4-2
Model TC24D—
Hydrostatic/Gear
Pressurized Liquid with
Recirculating Bypass
Centrifugal
V-Belt
10 mm-15 mm
(7/16"-9/16") when 9-11 kg (20-25
lbs.) thumb pressure is applied mid-
way between belt pulleys
335 mm (13.19")
82°C (200°F)
95°C (228.6°F)
0.9 bar
(13 PSI)
12-volt, heavy-duty, 40 amps
Solenoid
Pre-Engaged Reduction
Diesel
No. 2-Diesel, Cetane Rating:
Minimum 40
No. 1-Diesel, Cetane Rating:
Minimum 40
In-Line
24° BTDC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tc24d

Table of Contents