There are three dehumidification mode levels, and the dehumidification time
corresponding to different dehumidification levels is different. Exit the dehumidification
mode and select the normal mode. The default brightness value is 60% after exiting
the dehumidification mode.
1)
Dehumidification Mode 1 (low gear): The brightness gradually changes to 100%
within 1 hour, and the change process is 0-18 minutes, brightness is 10%, 18-36
minutes brightness is 20%, and 36-50 minutes brightness is 50%, 50-60 minutes
100%.
2)
Dehumidification Mode 2 (mid-range): The brightness gradually changes to 100%
within 2 hours, and the change process is 0-36 minutes, brightness is 10%, 36-72
minutes brightness is 20%, and 72-96 minutes brightness is 50%. %, 96-108
minutes brightness is 80%, 108-120 minutes 100%.
3)
Dehumidification Mode 3 (high grade): The brightness gradually becomes 100%
within 4 hours, the change process is 0% for 0-72 minutes, the brightness for
20-72 minutes is 20%, and the brightness for 144-192 minutes is 50%, 192- The
brightness is 75% in 216 minutes and 100% in 216-240 minutes.
Chapter 3 LED Display Control Setting
37