K-Systems G95 Instruction Manual

Portable incubator

Advertisement

Quick Links

K-SYSTEMS
Instruction Manual
Portable Incubator
G95

Advertisement

Table of Contents
loading

Summary of Contents for K-Systems G95

  • Page 1 K-SYSTEMS Instruction Manual Portable Incubator...
  • Page 2: Table Of Contents

    ....... . .9 5.1 Assembling the G95 ....... . .9 5.2 Connection to the mains .
  • Page 3 TABLE OF CONTENTS Instruction manual - G95 9. Gassing of CO² incubators ......27 9.1.
  • Page 4: General Information And Service

    This manual contains information that is subject to copyright. All rights reserved. This manual should not be photocopied, otherwise copied or distributed, completely or in part, without the approval of K-SYSTEMS Users of K-SYSTEMS products should not hesitate to contact us if there are any unclear points or ambi- guities in this manual. © K-SYSTEMS Kivex Biotec Ltd Klintehøj Vænge 3-5...
  • Page 5: Unpacking And Inspection

    Instruction manual - G95 2. Unpacking and inspection • Unpack the equipment. • Check the packing list to insure all accessories are there. • Examine the packing material carefully for separately packed items. • Check the incubator for external surface damage.
  • Page 6 Instruction manual - G95 Two plastic blocks for holding the warming blocks in place. Plastic insulation, white Order code: 50004 Plastic insulation, black Order code: 52772 Gas connector. Order code: 52156, 51086, 52192 Silicone tube. Order code: 11066 Page 3...
  • Page 7: Optional Equipment

    Instruction manual - G95 3.2 Optional equipment Optional equipment consists of a range of warming blocks, flowmeters and gas humidifiers. K-SYSTEMS recommends that the GH01 is used for supplying gas to the portable incubator. (see 3.3 Supplementary equipment) Warming blocks for tubes Warming block B06 Holds twelve tubes of Ø12 mm...
  • Page 8 Instruction manual - G95 Warming blocks for dishes Warming block B16 Holds two culture dishes B16F - Falcon 353001 Order code: 26059 B16N - NUNC 150318 Order code: 26060 Warming block B24 Holds one center well dish Falcon 353653 Order code: 260027...
  • Page 9 Holds one 5-well dish MiniTüb 19021/0005 Order code: 26030 3.3 Supplementary equipment The G95 is designed as a transport device, and not as a blockwarmer. It can be used in conjunction with the following K-SYSTEMS products. GH01 Stand alone humidifier to obtain correct...
  • Page 10: Users Manual

    4. Users Manual 4.1 Definition of use The K-SYSTEMS Kivex Biotec G95 Portable incubator is designed for transporting gametes and embryos which require protection form fluctuations in temperature, pH levels and light. The warming blocks should be pre warmed to the desired temperature and allowed to stabilise before placing inside the G95 transport incubator.
  • Page 11: Unit Performance

    Instruction manual - G95 4.3 Unit performance The unit is connected and allowed to stabilise to the setpoint. Culture dishes and/or test tubes are placed in the interchangeable warming blocks which are held in secure positions during transport. The chamber is purged with the desired gas mixture (regulated for example by the GH01). During purging, the door is closed, but only sealed after purging.
  • Page 12: Features And Operation

    The mains voltage is automatically regulated to the correct level by the main adapter (PSU). Connect the G95 to the mains supply using the enclosed PSU. For safety reasons the unit has an external PSU which operates at a low voltage.
  • Page 13: Operating The Heated Compartment

    Instruction manual - G95 5.4 Operating the heated compartment Action Display Press heat ON/OFF key to show the actual temperature. 5.5 Temperature setting and control The display indicates the average temperature of the chamber. Action Press setpoint key until set temperature is shown.
  • Page 14: Combination Keys

    Instruction manual - G95 5.6 Combination keys. Action Display Press alarm and UP key. The keyboard is locked. Press alarm and UP key. The keyboard is unlocked. Press Heat ON/OFF and setpoint key. Switches between temperature and time Press alarm and setpoint key to go into Switches off the powersave mode.
  • Page 15: Warming Up

    Always let the unit stabilise before use. 5.9 Warming blocks It is necessary to use warming blocks. Please contact your local distributor or K-SYSTEMS for details about the full range of warming blocks. A selection of different tubes and dishes can be transported. Either tubes or dishes can be transported at one time, not a combination of both.
  • Page 16: Overview Of Options

    Instruction manual - G95 The menu consist of the 10 options listed below. For further detail see the description on the following pages. 6.1 Overview of options ˚C Send UNIT Version 3 ˚F RS232 Off +0.05 TUNE -0.05 Calib. value +0.1...
  • Page 17: Unit

    Instruction manual - G95 UNIT In the UNIT option the displayed temperature unit can be selected to be either degrees Celsius or Fahrenheit. Follow these steps to navigate in the UNIT option. Action Display Press and hold UP+DOWN key for 3 seconds to enter the the menu.
  • Page 18: Rs232

    Instruction manual - G95 RS232 The RS232 option is for serial communication and data logging of the temperature and alarm conditions. Follow these steps to navigate in the RS232 option. Action Display Press and hold UP+DOWN key for 3 seconds to enter the the menu.
  • Page 19: Tune

    Also ensure an optimal contact between the sensor and the place measured. Use only a sensor type that is correct for the purpose and of correct size. If in doubt contact your local distributor or K-SYSTEMS. Page 16...
  • Page 20: Int.t

    Instruction manual - G95 INT.T The INT.T (Integral Time) option is for changing the base value for the PID controller. This should not be attempted by unauthorised persons. If set at a different level the controlling principle will be affected.
  • Page 21 Instruction manual - G95 St.St The St.St (Start Set) option is the timer function for the heat. By using this option, time can be saved as the G95 can be ready for use before procedures start in the morning. Note This function will only be working correctly if the clock is set.
  • Page 22: Heat

    Instruction manual - G95 HEAT The HEAT option is used for the heater to turn on at a time. Note This function only works in conjunction with St.St. If St.St is set to 8.00 and heat function is on, the heater will automatically turn on at 8.00 using 24 hour clock.
  • Page 23: A-St

    Instruction manual - G95 A-St The A-st (Automatic Start) option is used to repeat the timer (St.St) function every day of the week. Note This function works in conjunction with St.St and HEAT. If St.St is set to 8.00 and heat function is on, the heater will automatically turn on at 8.00 every day.
  • Page 24: Hour

    Instruction manual - G95 HOUR The HOUR option gives the opportunity to show the time on the display when the heat is off. Follow these steps to navigate in the HOUR option. Action Display Press and hold UP+DOWN key for 3 seconds to enter the the menu.
  • Page 25: Rest

    Instruction manual - G95 To change back to temperature Action Display Press and hold setpoint key . Press the HEAT key one time, then let go of the setpoint key. The display now shows the temperature. Note The time is shown as a 24 hour clock e.g 19.30 not 7.30 PM.
  • Page 26: Battery Functions

    A constant light in the HEAT key indicates that the unit is fully charged. The LED light will not be activated when the G95 is operating only on the internal battery. Page 23 Kivex Biotec Ltd...
  • Page 27: The Use Of Tubes Or Dishes

    The charge of the battery should hold for five hours, (depending on the ambient temperature) Note If the holding time for the battery is below five hours, please contact your local K-SYSTEMS distributor or K-SYSTEMS. 8. The use of tubes or dishes A selection of different tubes and dishes can be transported.
  • Page 28: Loading With Tubes

    Instruction manual - G95 8.1 Loading with tubes Put the two warming blocks in the com- partment. The metal-stop will keep them in place. Put the black plastic insulation piece in place and the blocks are fixated. Then the lid can be closed and sealed.
  • Page 29 Instruction manual - G95 There is a groove in the back that must fit over the metal-stop. Stack the warming blocks with the dishes in. Put the black plastic insulation piece in place and the blocks are fixated. Then the lid can be closed and sealed.
  • Page 30: Gassing Of Co² Incubators

    In order to reduce evaporation from the culture media, humidification of the gas mixture may be necessary if larger gas flow rates are used. We recommend the K-SYSTEMS GH01, which must be connected between the regulator and the G95 portable incubator.
  • Page 31: Purging

    The flowrate should be high for 20-30 seconds after opening and then set back to the lower value. When frequent openings of the portable incubator are required, it may be necessary to use a flowmeter with a flush-flow valve for rapid purging. In this case, K-SYSTEMS recommends the GH01. After gassing, the lid should then be se- cured with the two locks and the incubator is ready for transport.
  • Page 32: User Maintenace

    10. User maintenace 10.1 Cleaning The G95 is a low maintenance unit designed to be both easy to use and clean, plus it is durable due to its construction. All surfaces should be cleaned with a 70� alcohol solution on a clean cloth or lint-free paper towel.
  • Page 33: Trouble Shooting

    Instruction manual - G95 11. Trouble shooting SYMPTOM CAUSE ACTION Temperature alarm is on. Temperature more than Check the set tempera- +/- 0,5° C from set tem- ture. Wait for the tem- perature. perature to stabilise. No heating. Setpoint below ambient.
  • Page 34: Technical Data

    Instruction manual - G95 12. Technical data Material of cabinet and compartment Stainless steel Weight (without PSU and BLOCK) 5, 68 kg Overall dimensions incl. handle (WxDxH) 245x220x315 mm Chamber dimensions (WxDxH) 101x117x125 mm Temperature range 35,0° to 49,9°C Temperature accuracy +/- 0.2°...
  • Page 35: Spareparts

    Instruction manual - G95 13. Spareparts 13.1 List of spare part numbers DESCRIPTION PART NUMBER Electronics Power PCB 11251 Battery 51068 Lock for lid 44059 Keyboard 52266 Heating element 44064 Blanking plug 57017 Power connector 23067 RS-232 connector 23066 PSU and mains cable.
  • Page 36: Spare Parts - Exploded View

    Instruction manual - G95 13.2 Spare parts - exploded view 44064 Heating element 53870 Insulation 44059 53306 31060 52266 57016 11251 51298 52156 52156 57118 57017 51068 52525 23066 23067 51115 Page 33 Kivex Biotec Ltd...
  • Page 37: Limited Warranty

    (13) months from the date of shipment of the Product and from the point of origin, the product will be repaired, or at K-SYSTEMS Kivex Biotec option, replaced, at no charge. This limited warranty does not apply to products subjected to abnormal use or conditions, improper storage,...
  • Page 38: Liability

    K-SYSTEMS Kivex Biotec takes no responsibility for the results, use and/or performance of the product. K-SYSTEMS Kivex Biotec expects that use of the product will be confined to trained and expert users.