Never make any modifications to the Electrobloc. ▲ The electrical connection may only be established by qualified person- nel and must be carried out according to the Schaudt installation instructions. ▲ Connection work is to be carried out in tensionless condition only.
Page 3
24 hours with a 160 Ah battery. ▲ Do not operate the Schaudt solar charge regulator without a battery. This might damage the solar charge regulator or any connected consumers. If the battery is going to be changed or removed, take off the positive lead "+ Solarzelle"...
▲ This device is exclusively designed for installation into a vehicle. The Electrobloc EBL 269 is designed as a main power distibutor for motorhomes. The Electrobloc is a permanent installation. The Electrobloc is for charging batteries and supplying 12 V appliances with power.
Control and switch panel IT 269-3, LT 300 Auxiliary charging unit Schaudt battery charging unit type LAS... with up to 18 A charge current Additional 2-pin charging cable, lengths supplied on request Solar charge regulator Schaudt solar charge regulator type LR... for solar modules with a total cur- rent of 14 A incl.
Page 6
Instruction Manual Electrobloc EBL 269 Battery selector switch ▲ Danger of explosion from formation of detonating gas due to an incor- rectly set battery selector switch, defective batteries, defective Electrob- loc or an excessively high battery working temperature (more than 30 °C).
24 hours with a 160 Ah battery. ▲ Do not operate the Schaudt solar charge regulator without a battery. This might damage the solar charge regulator or any connected consumers. If the battery is going to be changed or removed, take off the positive lead "+ Solarzelle"...
If this is not possible, e.g. if you are abroad, you can have the Electrobloc repaired at a specialist workshop. Inexpert repairs invalidate the guarantee for the Electrobloc and Schaudt GmbH takes no liability for any resulting damage. Fault...
Instruction Manual Electrobloc EBL 269 Fault Possible cause Remedy The refrigerator does not No power supply to the Have the fuse and wiring work during mobile opera- refrigerator checked tion Defective Electrobloc Call customer service Defective refrigerator Have the refrigerator...
Instruction Manual Electrobloc EBL 269 Fault report In the event of damage, please return the defective device together with the completed fault report. Device type: EBL 269 Type no.: (please enter) There is the following defect: (please tick) Battery not...
Need help?
Do you have a question about the Electrobloc EBL 269 and is the answer not in the manual?
Questions and answers