Advertisement

© 2010 Schaudt GmbH, Elektrotechnik & Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Phone +49 7544 9577-0, Telefax +49 7544 9577-29, www.schaudt-gmbh.de
811.598 BA / EN
Instruction manual
0
Instruction Manual Electrobloc EBL 269
Electrobloc EBL 269

Table of contents

1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2
Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3
Description and appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4
Suitable accessories (not supplied) . . . . . . . . . . . . . . . . . . . . . . . . 5
5
Electrical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
6
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
7
Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
8
Shutting down the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
9
Changing the battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
10
11
Customer service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
12
Block diagram - for specialist workshop only . . . . . . . . . . . . . . . . 10
13
Fault report. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Situation: 25.06.2010

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Electrobloc EBL 269 and is the answer not in the manual?

Questions and answers

Summary of Contents for Schaudt Electrobloc EBL 269

  • Page 1: Table Of Contents

    Fault report......... . 11 © 2010 Schaudt GmbH, Elektrotechnik & Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Phone +49 7544 9577-0, Telefax +49 7544 9577-29, www.schaudt-gmbh.de 811.598 BA / EN...
  • Page 2: Introduction

    Never make any modifications to the Electrobloc. ▲ The electrical connection may only be established by qualified person- nel and must be carried out according to the Schaudt installation instructions. ▲ Connection work is to be carried out in tensionless condition only.
  • Page 3 24 hours with a 160 Ah battery. ▲ Do not operate the Schaudt solar charge regulator without a battery. This might damage the solar charge regulator or any connected consumers. If the battery is going to be changed or removed, take off the positive lead "+ Solarzelle"...
  • Page 4: Description And Appropriate Use

    ▲ This device is exclusively designed for installation into a vehicle. The Electrobloc EBL 269 is designed as a main power distibutor for motorhomes. The Electrobloc is a permanent installation. The Electrobloc is for charging batteries and supplying 12 V appliances with power.
  • Page 5: Suitable Accessories (Not Supplied)

    Control and switch panel IT 269-3, LT 300 Auxiliary charging unit Schaudt battery charging unit type LAS... with up to 18 A charge current Additional 2-pin charging cable, lengths supplied on request Solar charge regulator Schaudt solar charge regulator type LR... for solar modules with a total cur- rent of 14 A incl.
  • Page 6 Instruction Manual Electrobloc EBL 269 Battery selector switch ▲ Danger of explosion from formation of detonating gas due to an incor- rectly set battery selector switch, defective batteries, defective Electrob- loc or an excessively high battery working temperature (more than 30 °C).
  • Page 7: Maintenance

    24 hours with a 160 Ah battery. ▲ Do not operate the Schaudt solar charge regulator without a battery. This might damage the solar charge regulator or any connected consumers. If the battery is going to be changed or removed, take off the positive lead "+ Solarzelle"...
  • Page 8: Technical Faults, Possible Causes And Remedies

    If this is not possible, e.g. if you are abroad, you can have the Electrobloc repaired at a specialist workshop. Inexpert repairs invalidate the guarantee for the Electrobloc and Schaudt GmbH takes no liability for any resulting damage. Fault...
  • Page 9: Customer Service

    Instruction Manual Electrobloc EBL 269 Fault Possible cause Remedy The refrigerator does not No power supply to the Have the fuse and wiring work during mobile opera- refrigerator checked tion Defective Electrobloc Call customer service Defective refrigerator Have the refrigerator...
  • Page 10: Block Diagram - For Specialist Workshop Only

    12 V Heater regulator switch on the type LR... instrument panel. Step (15A**) Solar module Awning light (circuit 5**) Circuit board KPL EBL 269 type no. 771.498 Fig. 2 Block diagram of Electrobloc EBL 269 Situation: 25.06.2010 811.598 BA / EN...
  • Page 11: Fault Report

    Instruction Manual Electrobloc EBL 269 Fault report In the event of damage, please return the defective device together with the completed fault report. Device type: EBL 269 Type no.: (please enter) There is the following defect: (please tick) Battery not...
  • Page 12 Instruction Manual Electrobloc EBL 269 Situation: 25.06.2010 811.598 BA / EN...