Never make any modifications to the Electrobloc. ▲ The electrical connection may only be done by qualified personnel and must be carried out according to the Schaudt installation instructions. ▲ Electrical connections are to be carried out in tensionless condition only.
24 hours with a 160 Ah battery. ▲ Do not operate the Schaudt solar charge regulator without a battery. This might damage the solar charge regulator or any connected consumers. If the battery is going to be changed or removed, please first take off the pos- itive lead "+ Solar Module"...
● DT 100 or DT 200 with reduced functionality Auxiliary charging unit Schaudt battery charging unit type LAS... with up to 18 A charge current Additional 2-pin charging cable, lengths supplied on request Solar charge regulator Schaudt solar charge regulator type LR... for solar modules with a total cur- rent of 14 A with connector plug, including 0.5 m cable...
Instruction Manual Electrobloc EBL 101 Technical data Mains connection 230 V AC ± 10 %, 47 to 63 Hz sinusoidal, protection class I Suitable batteries 6-cell lead acid or lead gel batteries of at least 55 Ah Closed circuit current from...
Instruction Manual Electrobloc EBL 101 Operation Operating controls Flat vehicle fuses ▲ Blown fuses must only be replaced when the cause of the fault is known and eliminated. ▲ Never bridge or repair fuses. ▲ Danger of burning! Blown fuses must only be changed on an zero-cur- rent Electrobloc.
Page 7
Instruction Manual Electrobloc EBL 101 ❱ Set the battery cut-off switch on the Electrobloc to "Batterie Ein" (battery Starting up the system on). ❱ After switching on the battery cut-off switch or after changing batteries: Switch on the 12 V main switch at the control and switch panel briefly to put the consumers into service.
EBL 101 will however remain without a function. Maintenance The Electrobloc EBL 101 requires no maintenance. Cleaning Clean the Electrobloc with a soft, slightly damp cloth and mild detergent. Never use spirit, thinners or similar substances.
16 hours with a 160 Ah battery. ▲ Do not operate the Schaudt solar charge regulator without a battery. This might damage the solar charge regulator or any connected consumers. If the battery is going to be changed or removed, please first take off the pos- itive lead "+ Solar Module"...
If this is not possible, for example if you are abroad, you can have the Elec- trobloc repaired at a specialist workshop. Inexpert repairs invalidate the guarantee for the Electrobloc and Schaudt GmbH takes no liability for any resulting damage.
Page 11
Instruction Manual Electrobloc EBL 101 Fault Possible cause Remedy Living area battery is not Defective alternator Have the alternator charged during mobile checked operation (battery voltage No voltage at D+ input Have the fuse and wiring below 13.0 V) checked...
Instruction Manual Electrobloc EBL 101 Fault report In the event of damage, please return the defective device together with the completed fault report. Device type: EBL 101 Type no.: 911.550 There is the following defect: (please tick) Battery not being charged...
Need help?
Do you have a question about the Electrobloc EBL 101 and is the answer not in the manual?
Questions and answers