Control and switch panel
Auxiliary charging unit
Solar charge regulator
Mains connection
Suitable batteries
Current-carrying capacity
Flat vehicle fuses
Start up the system
Shutting down the system
811.598 BA / EN
Type no.
911.520
911.525
911.521
911.526
4
Suitable accessories (not supplied)
IT 269-3, LT 300
Schaudt battery charging unit type LAS... with up to 18 A charge current
Additional 2-pin charging cable, lengths supplied on request
Schaudt solar charge regulator type LR... for solar modules with a total cur-
rent of 14 A incl. 0.5 m connection cable and connector plug
5
Electrical data
230 V AC ± 10 %, 47 to 63 Hz sinusoidal, protection class I
6-cell lead acid or lead gel batteries of at least 55 Ah
12 V outputs
6
Operation
6.1
Operating controls
▲
Blown fuses must only be replaced when the cause of the fault is
known and eliminated.
▲
Never bridge or repair fuses.
▲
Danger of burning! Blown fuses must only be changed on a zero-cur-
rent Electrobloc.
▲
Only use original fuses rated as specified in the instruction manual.
The flat vehicle fuses protect the various circuits.
▲
Before starting up:
●
Make sure the living area battery is connected.
Make sure the battery selector switch is set for the correct type of bat-
●
tery.
●
Make sure the AES fuse is only used if the compressor/AES refrigera-
tor is connected. Otherwise, the living area battery may get totally dis-
charged. Battery damage is possible.
Switch on the system using the 12 V main switch at the control and switch
panel. Follow the instruction manual of the control and switch panel.
Switch off the system using the 12 V main switch at the control and switch panel.
Instruction Manual Electrobloc EBL 269
Fuse value
2.5 A slow blow
2.5 A slow blow
3.15 A slow blow
3.15 A slow blow
No more than 90 % of the rated current
of the appropriate fuse may be drawn,
see the block diagram.
Situation: 25.06.2010
5