23. The NETCOM Program Settings screen indicates it is waiting for a NETCOM reset or
power cycle. Momentarily short the Reset jumper on the NETCOM2P and follow the
on-screen prompts.
24. If the PC/laptop and the CIM-LINK/NETCOM2P are connected to the network, you can
PING the device to verify a network connection. Select Start PING and wait for the
PING Status Result message – IP Success.
If you receive a Timed Out result, check the settings and connections.
25. Leave the NETCOM2 Program Utility open. You will require it to program the NETCOMP
for the subordinate communication loop.
Disconnect the serial cable or USB-SER adaptor from the CIM-LINK's terminal
block COM2 (TB3).
26. Remove the jumper from J12 on the CIM-LINK module.
27. Place a jumper momentarily on J1 RESET on the CIM-LINK module.
Steps to Program the NETCOM2P – CIM-LINK on Subordinate
Communication Loop
1.
Mount the CIM-LINK module with the NETCOM2P in the designated location on the
subordinate communication loop. Ensure that the NETCOM2P is mounted securely.
2.
Connect the serial cable or USB-SER adaptor to the CIM-LINK terminal block COM2
(TB3) and the PC or laptop with the NETCOM2 Utility software.
3.
Place a jumper on J12 on the subordinate CIM-LINK module.
4.
Turn on the laptop or PC connected to the CIM-LINK module.
5.
Connect the CIM-LINK module to a power source or connect the ribbon cable to H2 on
the control board. If using the latter method, ensure the control board has power
from the DPS-15.
6.
Momentarily place a jumper on J1 RESET on the CIM-LINK module.
7.
From the Keyscan NETCOM Utility screen, click Program NETCOM Device.
8.
From the Select NETCOM Device Type screen, select NETCOM2/2P.
9.
From the Program NETCOM2B, NETCOM2 & NETCOM2P Boards screen, enter the IP
address of the NETCOM2P connected to the CIM-LINK module on the subordinate
communication loop.