In the case of a star network, the floodlight must be connected to the power sup-
ply as follows:
L
= Phase
N
= Neutral conductor
PE
= Protective earth conductor
In the case of a delta network, the floodlight must be connected to the power
supply as follows:
L1
= Phase
L2
= Neutral conductor
PE
= Protective earth conductor
Max. 1 conductor can be connected at the terminal points (1) to (3). The connec-
tion terminal is suitable for the following line cross sections:
Applies to: FL601. . . . to FL606. . . . and FL60N4. . . . Navy,
as shown in Figure 3 to 6:
Flexible lines without wire end sleeve
Rigid lines
The following terminal points are also available for use, if required:
PE
= Protective earth conductor - Terminal points (4)
Max. 1 conductor can be connected at the terminal points (4). The connection
terminal is suitable for the following line cross sections:
Flexible lines without wire end sleeve
Rigid lines
The modules are connected at the terminal points (5) or the terminal points re-
main free.
Applies to: FL60S4. . . . as shown in Figure 7:
Fine wires with wire end sleeve
Stranded wires with wire end sleeve
Solid wires
Cable sheath Ø
- Terminal points (1)
- Terminal points (2)
- Terminal points (3)
- Terminal points (1)
- Terminal points (2)
- Terminal points (3)
0.5 to 10.0mm²
0.5 to 10.0mm²
0.5 to 16.0mm²
0.5 to 16.0mm²
0.5 to 1.5 mm²
0.75 to 1.5 mm²
0.5 to 2.5 mm²
6.0 to 10.0 mm