Glamox FX61 Operating Instructions Manual

Explosion-proof floodlight with led

Advertisement

Quick Links

Explosion-proof floodlight with LED
FX61
Terminal Box
Stainless Steel 1.4404 / AISI 316L
7179750302 / Index 12
Glamox AS
Birger Hatlebakksveg 15
NO-6415 Molde
www.glamox.com
06.09.2022
Operating instructions
Terminal Box
Polyester GF
Polyester GF
CG at the side
de
en
fr
tr
el
es
pt
da
nl
no
sv
pl
cs
hu
.
Seite 1 von 40

Advertisement

Table of Contents
loading

Summary of Contents for Glamox FX61

  • Page 1 Explosion-proof floodlight with LED Operating instructions FX61 Terminal Box Terminal Box Polyester GF Stainless Steel 1.4404 / AISI 316L Polyester GF CG at the side Glamox AS Birger Hatlebakksveg 15 NO-6415 Molde www.glamox.com 7179750302 / Index 12 06.09.2022 Seite 1 von 40...
  • Page 2 The operating instructions must be read carefully before using the product. GLAMOX RESERVES THE RIGHT TO MAKE TECHNICAL CHANGES TO THE DESCRIBED PRODUCTS. Page 2 of 40 06.09.2022 7179750302 / Index 12...
  • Page 3: Table Of Contents

    Table of Contents Foreword ................. 4 Safety ..................6 Generel ................6 Intended use ................ 6 Improper use................ 7 Product observance ............. 7 Requirements for the personnel ........... 7 Safety and accident prevention regulations ......8 Labelling in accordance with Directive 94/9/EC ....9 Safety labels ..............
  • Page 4: Foreword

    Foreword Dear reader, These operating instructions will familiarize you with safety compatible operation of the product. Our product has been designed and constructed according to the state of the art and the recognized rules of safety technology. Nevertheless, hazards can result for persons or objects, as not all hazard points can be avoided if the functionality is to be retained.
  • Page 5 Meanings in the operating instructions The following agreements for the operating instructions are to be made for better understanding: Two types of special notes are used to emphasize important information. This symbol can be found next to all warning notes that are to be indicated in plain text.
  • Page 6: Safety

    Safety General Knowledge of the safety notes and the safety regulations is a basic prerequisite for safety-compatible and fault-free operation of the product. Therefore read through this chapter carefully before operating the product and always observe the notes and warnings listed. The safety notes and warnings found at the corresponding point in the text of the following chapters must also be observed.
  • Page 7: Improper Use

    Improper use Every use that deviates from that described in the section "Intended use" is deemed to be improper. Already occurring improper uses are not known to the manufacturer. Product observance Please inform us immediately if malfunctions or problems occur during operation of the explosion-proof floodlight.
  • Page 8: Safety And Accident Prevention Regulations

    Safety and accident prevention regulations Besides the safety and accident prevention regulations of the employers‘ liability insurance associations, the following notes must be observed in order to avoid personal injury and material damage: • The explosion-proof floodlight must only be operated for its intended use, as otherwise hazardous situations resulting in injuries or death can occur (see section “Intended use”).
  • Page 9: Labelling In Accordance With Directive 94/9/Ec

    • Immediately replace cables if crack formations or other damage is visible. • Only use original spare parts and accessories released by the manufacturer. The liability for the resultant consequences shall expire if other parts are used. Labelling in accordance with Directive 2014/34/EU Several devices as defined by the Directive 2014/34/EU have been installed in this floodlight.
  • Page 10: Safety Labels

    Safety labels In addition to the safety notes in these operating instructions, labels are attached to the product to warn against certain hazards. The meaning of these safety la- bels is described in the tables below. – WARNING APPROVAL EXPIRES WITHOUT SAFETY LABEL!
  • Page 11: Main Components

    Furthermore, the standards applicable for this explosion-proof operating equipment for gas explosive areas are fulfilled: • EN 60079-0:2018 (IEC 60079-0:2017) • EN 60079-1:2014 (IEC 60079-1:2014) • EN 60079-7:2015/A1:2018 (IEC 60079 7:2017) • EN 60079-28:2015 (IEC 60079-28:2015) This chapter aims to illustrate the structure and function of the explosion-proof floodlight.
  • Page 12: Installation

    consumers may be connected to the power supply line for the floodlight and operated. We also recommend 3-phase operation. The floodlight, in particular heat sink and lamp covers of the modules, must al- ways be kept in a clean condition. Corresponding to the applicable standards, a non-resettable fuse must be used to prevent the maximum permissible surface temperature in the event of a fault.
  • Page 13: Permissible Installation Positions

    Permissible installation positions As a rule, the installation of the floodlight is only permissible in locations where the effects of additional heat or cold sources can be excluded. The assembly is only permissible in those positions in which the individual modules are aligned as shown in Figure 1.
  • Page 14: Threaded Cable Glands

    Threaded cable glands Every floodlight is equipped with two threaded cable glands to introduce the installation lines. The permissable line diameter has to be conform to the specification of the manufacturer. The operation instructions of the line and cable gland is included in delivery of the floodlight. Each of these threaded cable glands is closed with a blind plug at the factory.
  • Page 15: Floodlight Connection

    Floodlight connection Disconnect the power supply line and secure against unauthorized reactivation before beginning the work. The connection terminal is suitable for through-wiring. Figure 4: Connection terminal FX611 ..Figure 5: Connection terminal FX612 ..to FX614 ..7179750302 / Index 12 06.09.2022 Page 15 of 40...
  • Page 16 In the case of a star network, the floodlight must be connected to the power sup- ply as follows: • = Phase - Terminal points (1) • = Neutral conductor - Terminal points (2) • = Protective earth conductor - Terminal points (3) In the case of a delta network, the floodlight must be connected to the power supply as follows: •...
  • Page 17: Handling The Connection Terminal

    Handling the connection terminal Single-wire lines can be contacted without using a tool. Figure 6: Contacting without using a tool Multiple wire lines or lines with small wire cross sections can be contacted using a screwdriver. Figure 7: Contacting using a screwdriver 7179750302 / Index 12 06.09.2022 Page 17 of 40...
  • Page 18: External Potential Conductor

    External potential conductor A connection option for a potential equalization conductor via a screw terminal connection is provided for conducting away an electrical potential difference between the floodlight and supporting element (mount, wall or similar). The cross section of the connected line must at least correspond to the cross section of the phase conductor of the connecting line.
  • Page 19: Maintenance And Repair

    Maintenance and Repair Special Safety Regulations Compliance with the maintenance and repair work described in this chapter is part of the intended use of the floodlight. Maintenance and repair work may only be carried out by trained and qualified persons. This applies in particular for maintenance and repair work on the electrical system.
  • Page 20: Troubleshooting

    Test for Measure Lamp cover Damage and cracks Replace module Threaded cable gland Porosity of the sealing ring Replace threaded cable at the cable gland Heat sink of the individual Impurities, foreign bodies Cleaning modules Safety labels, rating plates Legibility and adhesion Replace labels Ex labelling Legibility...
  • Page 21: Customer Service

    Customer Service The Customer Service department of Glamox AS will be pleased to help you when ordering spare parts, for maintenance and repair work as well as in case of problems and questions. Technical Data Lamp: Power: FX611 ..
  • Page 22: Ex Marking

    FX6160...; FX6163…; FX6166…; max. 1,08A FX6161...; FX6164…; FX6167…; max. 2,03A FX6162...; FX6165…; FX6168…; max. 0,96A FX61.0...; FX61.3…; FX61.6…; 230V ±10% 50/60Hz Voltage: FX61.1...; FX61.4…; FX61.7…; 120V ±10% 50/60Hz FX61.2...; FX61.5…: FX61.8…; 254V ±10% 50/60Hz Protection type: IP 67 (EN 60529)
  • Page 23 Ex db eb op is IIC T4 Gb 7179750302 / Index 12 06.09.2022 Page 23 of 40...
  • Page 24: Order Numbers

    Order numbers Beam width Type Voltage / Terminal box narrow medium wide 230 V Stainless Steel FX61100XXX FX61101XXX FX61102XXX 230 V Polyester GF FX61130XXX FX61131XXX FX61132XXX 230 V Polyester GF FX61160XXX FX61161XXX FX61162XXX CG at the side 120 V Stainless Steel FX61110XXX FX61111XXX FX61112XXX...
  • Page 25 Beam width Type Voltage / Terminal box narrow medium wide 230 V Stainless Steel FX61300XXX FX61301XXX FX61302XXX 230 V Polyester GF FX61330XXX FX61331XXX FX61332XXX FX61360XXX FX61361XXX FX61362XXX 230 V Polyester GF CG at the side 120 V Stainless Steel FX61310XXX FX61311XXX FX61312XXX 120 V...
  • Page 26: Dimensions

    230 V Stainless Steel FX61600XXX FX61601XXX FX61602XXX 230 V Polyester GF FX61630XXX FX61631XXX FX61632XXX 230 V Polyester GF FX61660XXX FX61661XXX FX61662XXX CG at the side 120 V Stainless Steel FX61610XXX FX61611XXX FX61612XXX 120 V Polyester GF FX61640XXX FX61641XXX FX61642XXX 120 V Polyester GF FX61670XXX FX61671XXX...
  • Page 27 Figure 9b: Explosion-proof floodlight type FX611 ..with Terminal box Polyester GF. Figure 9c: Explosion-proof floodlight type FX611 ..with Terminal box Polyester GF CG at the side 7179750302 / Index 12 06.09.2022 Page 27 of 40...
  • Page 28 Figure 10a: Explosion-proof floodlight type FX612 ..with Terminal box Stainless Steel. Figure 10b: Explosion-proof floodlight type FX612 ..with Terminal box Polyester GF. Page 28 of 40 06.09.2022 7179750302 / Index 12...
  • Page 29 Figure 10c: Explosion-proof floodlight type FX612 ..with Terminal box Polyester GF CG at the side Figure 11a: Explosion-proof floodlight type FX613 ..with Terminal box Stainless Steel. 7179750302 / Index 12 06.09.2022 Page 29 of 40...
  • Page 30 Figure 11b: Explosion-proof floodlight type FX613 ..with Terminal box Polyester GF. Figure 11c: Explosion-proof floodlight type FX613 ..with Terminal box Polyester GF CG at the side Page 30 of 40 06.09.2022 7179750302 / Index 12...
  • Page 31 Figure 12a: Explosion-proof floodlight type FX614 ..with Terminal box Stainless Steel. Figure 12b: Explosion-proof floodlight type FX614 ..with Terminal box Polyester GF. 7179750302 / Index 12 06.09.2022 Page 31 of 40...
  • Page 32 Figure 12c: Explosion-proof floodlight type FX614 ..with Terminal box Polyester GF CG at the side Figure 13a + 13b: (not available) Figure 13c: Explosion-proof floodlight type FX614 ..with Terminal box Polyester GF CG at the side Page 32 of 40 06.09.2022...
  • Page 33: Spare Part Numbers

    Spare part numbers Figure 14a + 14b: (not available) Figure 14c: Spare part numbers for floodlight type FX611 ..with Terminal box Polyester GF CG at the side Figure 15a: Spare part numbers for floodlight type FX612 ..with Terminal box Stainless Steel. 7179750302 / Index 12 06.09.2022 Page 33 of 40...
  • Page 34 Figure 15b: Spare part numbers for floodlight type FX612 ..with Terminal box Polyester GF. Figure 15c: Spare part numbers for floodlight type FX612 ..with Terminal box Polyester GF CG at the side Page 34 of 40 06.09.2022 7179750302 / Index 12...
  • Page 35 Figure 16a: Spare part numbers for floodlight type FX613 ..with Terminal box Stainless Steel. Figure 16b: Spare part numbers for floodlight type FX613 ..with Terminal box Polyester GF. 7179750302 / Index 12 06.09.2022 Page 35 of 40...
  • Page 36 Figure 16c: Spare part numbers for floodlight type FX613 ..with Terminal box Polyester GF CG at the side Figure 17a: Spare part numbers for floodlight type FX614 ..with Terminal box Stainless Steel. Page 36 of 40 06.09.2022 7179750302 / Index 12...
  • Page 37 Figure 17b: Spare part numbers for floodlight type FX614 ..with Terminal box Polyester GF. Figure 17c: Spare part numbers for floodlight type FX614 ..with Terminal box Aluminum. Figure 18a + 18b: (not available) 7179750302 / Index 12 06.09.2022 Page 37 of 40...
  • Page 38 Figure 18c: Spare part numbers for floodlight type FX616 ..with Terminal box Polyester GF CG at the side Page 38 of 40 06.09.2022 7179750302 / Index 12...
  • Page 39: Tightening Torques

    Tightening torques Size Tightening torque Module 7 Nm Floodlight on holder 35 Nm Floodlight 60 Nm 7179750302 / Index 12 06.09.2022 Page 39 of 40...
  • Page 40: Annex

    Size Tightening torque Cover for junction box 2 Nm Junction box 7 Nm Cable Gland: 20Nm Cap Nut: 20Nm M25x1.5 Potential conductor 2.5 Nm Table 7: Tightening torques for fastening screws Page 40 of 40 06.09.2022 7179750302 / Index 12...