Download Print this page

olympia electronics SLIM LIGHT Series Manual page 3

Maintained/non-maintained (optional) luminaire

Advertisement

GR-2000 WITH REMOTE CONTROL
OPERATIONS
OF REMOTE CONTROL
(To operate the remote control you must first remove the transparent protective battery
from
the bottom of the device).
Explanation of
the
1. Button
ON:
l
ights
or
from the mains power supply
2. Button
OFF:
turns off the
mode
or
from the mains power supply
3. Button
s
 ‚
Ì
: increases or decreases the brightness of the
luminaire
in a state
button once, the luminosity will decrease to
same button for second time the luminosity will reach the lowest level
of
30%
of the nominal luminosity If the
red led will light as indication of the luminosity's lowest level The
button operates with the opposite way. If you press sequentially the
button, the luminosity can increase from
100%.
Any additional pressure of the button will activate the red led
as indication of the luminosity's highest level
4. Button
s
E
: increases or decreases the brightness of the
 ‚
l
luminaire
in a state
5. (*) Button
s
SET + TEST
emergency
operation
6. (*) Button
s
SET + DUR TEST
duration test when the battery is fully charged
blinks the test will not be conducted
)
7. (*) Button
s
SET + DUR OFF
month
duration test indefinitely
flash every 2 seconds.
8. (*) Button
s
SET + ERR CLR
indications of the luminaire.
9. (*) Button
s
SET + M / NM
mode
to
non-
maintained mode
to non-maintained, the red indication led will blink once. During the change of operation from
non-maintained to maintained the red indication led will blink twice.
10. (*) Button
s
SET + F1
light as before.
When the sensor is deactivated, the orange indication led will blink once and
when is reactivated the orange indication led will blink twice.
(*) Combination of keys: briefly press the
The
ÉÍÇ
and
F2
key
GR-2000 WITHOUT REMOTE CONTROL
TEST BUTTON FUNCTIONS (Valid also for remote controlled models).
If
the test button is
mains power supply
condition is not permanent and if the mains power supply is restored then, in the next
interruption, the luminaire will light in emergency mode) If the luminaire is turned off by
pressing the test button in emergency mode, then you can turn it on by pressing the test button
again.
- Check
emergency
By briefly
pressing
operating
system
is tested
-
Fault reset
(
with mains power supply present)
Performed by continuous
lighting of
the
3
indication
-
selecting maintained or non-maintained operation
Page
3
from
4
function keys:
the
luminaire
when operating in
.
luminaire
when operating in
.
of mains power supply By pressing the
.
of
emergency operation
(
with mains power supply present)
circuit
.
(
with mains power supply present)
(the Red led will blink).
(
with mains power supply present)
. When the cancellation is active, the orange LED gives a brief
To reactivate this test press the
(
with mains power supply present) extinguish all fault
(
with mains power supply present)
and vice versa.
(
with mains power supply present)
are
not used (
the
ÉÍÇ
pressed, when the
) the LED
s are switch OFF
operation
(
with mains power supply present)
the
button
will light the lighting
.
ly
pressing
the button
LED .
s
IRT200 (for models that support remote control).
emergency mode
emergency
.
65%.
By pressing the
button is pressed again, the
30%
to
65%
and finally to
.
as the operation of the
. If it is
not
SET + DUR OFF
During the change of operation, from maintained
:
SET
button and then the next key (not simultaneously).
button can be active after request).
luminaire
is in
emergency
, to avoid wasting the battery power (
.
LED
s for 3 sec.
.
for 5 seconds and confirmed by the sequential
(
with mains power supply present)
.

 ‚
Ì
buttons
:
perform
s a test of the
:
perform a full autonomy
s
fully charged (the green indicator
:
cancel the automatic six-
s
b
utton (*)
s
:
:
toggles
from maintained
activates or deactivates the sensor
mode (
during interruption of
.
In this way
the emergency
923200000_09_003
insulator
.
.
this
.

Advertisement

loading

This manual is also suitable for:

Gr-2000